EEWORLDEEWORLDEEWORLD

Part Number

Search

BR13-675A9-26V

Description
Power/Signal Relay, DPDT, Momentary, 0.039A (Coil), 26VDC (Coil), 1014mW (Coil), 5A (Contact), 28VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount,
CategoryMechanical and electronic products    relay   
File Size668KB,2 Pages
ManufacturerBabcock Inc
Download Datasheet Parametric View All

BR13-675A9-26V Overview

Power/Signal Relay, DPDT, Momentary, 0.039A (Coil), 26VDC (Coil), 1014mW (Coil), 5A (Contact), 28VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount,

BR13-675A9-26V Parametric

Parameter NameAttribute value
MakerBabcock Inc
Reach Compliance Codeunknown
Other featuresPANEL MOUNTABLE
body width10.41 mm
body height22.86 mm
Body length or diameter20.57 mm
Maximum coil current (DC)0.039 A
Coil operating voltage (DC)18 V
Coil power1014 mW
Coil release voltage (DC)1.3 V
Coil resistance675 Ω
Maximum coil voltage (DC)26 V
Coil/Input Power TypeDC
Maximum contact current (DC)5 A
Contact (DC) maximum rated R load5A@28VDC
Maximum contact voltage (DC)28 V
Contact/Output Power TypeDC
JESD-609 codee3
Manufacturer's serial numberBR13
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours7 ms
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
physical size20.57mm X 10.41mm X 22.86mm
GuidelineMIL-PRF-39016
Relay actionMOMENTARY
Relay functionDPDT
Relay typePOWER/SIGNAL RELAY
release time7 ms
surface mountNO
Terminal surfaceTIN
Termination typeSOLDER
Base Number Matches1
BR13
Crystal Can
Welded • DPDT
Dry Circuit to 5 Amps
SPECIFICATIONS
GENERAL
Contact Arrangement
.......................... 2PDT (2 Form C)
Weight.........................................................
1.3 oz approx.
Designed to meet the requirements of MIL-PRF-39016.
PERFORMANCE
Contact Rating
(Note 1)
Resistive:
BR13 ......................................... 5 Amps @ 28 VDC
BR13H.................3 Amps @ 28 VDC or 2 Amps @
115 VAC, 400 Hz (Case Ungrounded)
BR13K ........................................2 Amps @ 28 VDC
115 VAC, 400 Hz (Case Ungrounded)
Inductive ........................................... 1 Amp @ 28 VDC
Low Level ............................ 10-50 µA @ 10-50 mv DC
or peak AC (Note 4)
Pull In Power:
BR13.....................................................250 mw approx.
BR13H..................................................100 mw approx.
BR13K ....................................................40 mw approx.
Operate/Release Time:
BR13............................................................... 5 ms max
BR13H............................................................ 6 ms max
BR13K .......................................................... 15 ms max
excluding bounce time at nominal coil voltage
Contact Bounce Time:
BR13 and BR13H .............2 MS max @ 2 and 3 Amps
@ 28 VDC
BR13K ........................... 2 MS max @ 2 Amps 28 VDC
Contact Resistance:
Before Life.......................0.050 Ohms @ rated current
and 6 VDC
After Life ..........................0.100 Ohms @ rated current
and 6 VDC
ENVIRONMENTAL
o
o
Temperature Range
............................... -65 C to +125 C
Vibration
(Note 2):
BR13............................................... 0.4" DA 10 - 38 Hz,
20 G's 38 - 2,000 Hz
BR13H and BR13K........................ 0.4" DA 10 - 31 Hz,
20 G's 31 - 2,000 Hz
Shock (Operating) (Note 2) .......................... 50 G's 11 ms
ELECTRICAL CHARACTERISTICS
Duty Cycle........................................................Continuous
o
Insulation Resistance..
10,000 megohms @ 500V 25 C
o
1,000 megohms @ 500V 125 C
Dielectric Strength:
Sea Level:
Contact to Case ................................... 1,000 VRMS
Contact to Coil ..................................... 1,000 VRMS
Coil to Case ......................................... 1,000 VRMS
Across Open Contacts:
BR13 and BR13H ................................ 750 VRMS
BR13K.................................................. 500 VRMS
70,000 Feet
All points.................................................. 350 VRMS
Notes:
1. For case grounded loads and other ratings, consult the
factory.
2.
For applications requiring other shock and vibration
levels, consult the factory.
3.
4.
For other ratings consult the factory.
Relay contacts which have switched high level currents
are no longer suitable for switching low level loads.
14930 E. Alondra Blvd., La Mirada, CA 90638-5752 (714) 994-6500 FAX (714) 994-3013
W: 2000 Rev. 3

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1929  2144  673  274  2865  39  44  14  6  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号