Specification Control Drawing
HIGH TEMPERATURE HOOKUP WIRE, TIN PLATED COPPER, RADIATION-CROSSLINKED,
MODIFIED ETFE INSULATED, 200°C, 600 VOLT
The complete requirements for procuring the wire described herein shall consist of this document, the issue in effect of
Test Regime WSD 3106 (UK), WCD3106, UL Subject 758, Style 3557, File E38136 and carries UL labels to this effect.
FLHTC0311
Issue 7
28th March 2013
Page 1 of 2
Page 2 is for internal use only
Conductor -
Tin Plated Copper
Jacket -
Radiation Crosslinked
Modified ETFE
Part
Description
Nominal
CSA
(mm²)
Conductor
Stranding
No./ Diam.
(mm)
19/0.13
19/0.15
19/0.19
19/0.23
19/0.25
19/0.32
19/0.36
19/0.41
Conductor
Diameter
(mm)
Min.
0.55
0.74
0.86
1.05
1.17
1.35
1.66
1.85
Max.
0.63
0.76
0.88
1.08
1.26
1.58
1.79
2.01
FLHTC0311-0.25-*
FLHTC0311-0.35-*
FLHTC0311-0.50-*
FLHTC0311-0.75-*
FLHTC0311-1.00-*
FLHTC0311-1.50-*
FLHTC0311-2.00-*
FLHTC0311-2.50-*
PART DESCRIPTION:
0.25
0.35
0.50
0.75
1.00
1.50
2.00
2.50
Maximum
Resistance
@ 20°C
(ohms/ km)
83.3
52.2
40.1
24.7
20.0
13.7
9.7
8.2
FINISHED WIRE
Crosslink
Diameter (mm)
Nominal
Verification Test
Lower
Upper
Weight
Spec
Target
Spec
(kg/ km) Mandrel OD Weight
Limit
Limit
(mm) (±3%) (kg) (±3%)
0.96
1.00
1.03
2.95
9.5
0.23
1.12
1.16
1.19
4.22
13
0.36
1.24
1.27
1.31
5.59
13
0.50
1.43
1.47
1.51
7.95
13
0.50
1.58
1.62
1.66
9.9
13
0.50
1.82
1.87
1.92
15.7
19
0.68
2.05
2.10
2.16
18.7
25
0.91
2.24
2.31
2.38
24.6
38
1.36
The '*' in the part description shall be replaced by a standard colour code designator,
e.g. FLHTC0311-1.50-9 is 1.50mm², white insulation
Sizes 0.25 - 2.00
Size 2.50
Crosslink Verification:
0.15 mm minimum; 0.165 mm (minimum average)
0.165 mm minimum; 0.178 mm (minimum average)
Time/ temperature - WCD3106 clause 3.3.4; voltage withstand - 2.5 kV;
mandrels and weights as shown
37.7 N/mm² minimum
100% minimum
To UL Factory Inspection Procedure, Subject 758 (Page 40), Style 3557 at 200°C
T2/ T1 minimum = 0.80
7 days @ 232°C; Insulation elongation 60% minimum,
Insulation Tensile Strength 34.5 N/mm² minimum
3 mm maximum at each end at 200°C/ 1 hour
1524 Mohm.km minimum
8.0 kV Impulse
This specification sheet takes precedence over documents referenced
herein. As Tyco Electronics UK Ltd. reserve the right to make changes
in construction without notice please contact Tyco Electronics UK Ltd to
ensure that this document is the latest issue.
INSULATION THICKNESS:
ADDITIONAL REQUIREMENTS:
Insulation Tensile Strength:
Insulation Elongation:
Deformation Test:
Thermal Stability:
Shrinkage:
Insulation Resistance:
Spark Test:
Tyco Electronics UK Ltd
Faraday Road
Dorcan
SWINDON
SN3 5HH
Tel: +44 (0)1793 528171
Fax: +44 (0)1793 572516
TE Connectivity is a trading name of Tyco
TE Connectivity is a trading name of Tyco
Electronics UK Ltd, which is registered in
Electronics UK Ltd, which is registered in
England and Wales, number 550926.
England and Wales, number 550926.
Registered office: Faraday Road, Dorcan,
Registered office: Faraday Road, Dorcan,
Swindon, SN3 5HH
Swindon, SN3 5HH
Website:
Website:
www.te.com
This drawing and the information set forth hereon are the property of Tyco
Electronics UK Ltd, and are to be held in trust and confidence. Publication,
duplication, disclosure or use for any purpose not expressly authorised in
writing by Tyco Electronics UK Ltd is prohibited.
©2013 Tyco Electronics UK Ltd, a TE Connectivity Ltd. company. All Rights Reserved.