CUSTOMER DRAWING
Product Name
B-023-00
B-023-01
B-023-02
B-023-03
B-023-04
B-023-07
øA
min
4.3
5.5
7.0
10.5
2.4
3.1
Product Dimensions
øB
min
5.6
5.5
8.13
10.5
3
4.5
L
max
31
41
39
45
19
29
MATERIALS
1. INSULATION SLEEVE: Heat-shrinkable, transparent clear, modified polytetrafluorethylene.
2. SOLDER PREFORM WITH FLUX:
SOLDER: TYPE Pb93 per ANSI-J-STD-006.
FLUX:
TYPE ROM1 per ANSI-J-STD-004.
3. MELTABLE SEALING RINGS: Modified fluorinated ethylene propylene.
APPLICATION
1. These controlled soldering devices are designed for termination of a nickel plated copper shield of a cable having an insulation
rated for at least 200°C continuous.
2. Temperature range: -65°C to +260°C. For cable preparation and installation tool, consult RPIP-666-00.
Tyco Electronics
300 Constitution Dr
Menlo Park, CA 94025,
U.S.A.
TITLE:
SOLDERSLEEVE DEVICE SHIELD TERMINATION
HIGH TEMPERATURE
DOCUMENT NO.:
Unless otherwise specified dimensions are in
Raychem
millimeters.
Devices
[Inches dimensions are shown in brackets]
Tyco Electronics reserves the right to
ANGLES: N/A
TOLERANCES:
amend this drawing at any time. Users
0.00 N/A
should evaluate the suitability of the
ROUGHNESS IN
0.0 N/A
product for their application.
MICRON
0 N/A
FILE:
DRAWN BY:
CAGE CODE:
ECO:
B-023-0X
REV:
DATE:
A
SCALE:
SIZE:
27-Aug-07
SHEET:
P.TALLY
06090
B-023-0X_CD
07-020120
NTS
A
1 of 1
If this document is printed it becomes uncontrolled. Check for the latest revision.