EEWORLDEEWORLDEEWORLD

Part Number

Search

DTS20Z11-02PN-6149

Description
DTS20Z11-02PN-6149
CategoryThe connector   
File Size452KB,2 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

DTS20Z11-02PN-6149 Online Shopping

Suppliers Part Number Price MOQ In stock  
DTS20Z11-02PN-6149 - - View Buy Now

DTS20Z11-02PN-6149 Overview

DTS20Z11-02PN-6149

DTS20Z11-02PN-6149 Parametric

Parameter NameAttribute value
Connector Systemline to panel, line to panel
Sealableyes
Connectors and terminals terminate toWires and cables
Housing size11
shieldyes
Connector typefemale end, female end
Housing typeSquare flange female end
Number of Positions2
Number of power supply locations2
Number of signal positions0
Pre-installedno
Shell plating materialblack zinc nickel alloy
Shell materialAluminum 6061-T6
Insulation MaterialsHard dielectric/silica gel
Sealedno
Contact Current Rating (Max) (A)13
reverse polarityno
Terminal layout11 – 2
Terminal typePin
Connector mounting typePanel
polar codeN
Joint alignment typekeying
joint fixationwith
Location monitoringTiming
Cable size.52 – 1.31 mm² [ 20 – 16 AWG ]
Working group temperature range-65 – 200 °C [ -85 – 392 °F ]
Circuit ApplicationPower
High Current Circular Connectors (DTS-HC)
The Deutsch DTS-HC series connector is
ideally suited for power control systems
for military vehicles using a 8mm
2
, 16mm
2
or 25mm
2
cable. With both high electrical
power and signal contacts within the
same body. The power contacts are rated
to 150 amps and are suitable for power
ring main supplies.
FEATURES
Dual contact design
High current contacts
100% scoop proof design
Grounding fingers
Elastomer interface
RFI fingers at mating interface
Removable rear crimp contacts
Dedicated back fitting and grommet
GENERAL SPECIFICATION
Material:
Shell/coupling ring:
Plating:
High Strength Aluminium Alloy
Nickel (RoSH compliant) (standard)
Olive Drab Cadmium (optional)
Zinc Cobalt (optional)
Gold plated Copper Alloy
Size 4 service rating 150 Amp
Size 20 service rating in accordance
with MIL-C-38999
Crimp
8mm
2
, 16mm
2
& 25mm
2
cable
CENELEC Specification HD516
20-04 AWG cable
Dubius Tool D51
31040
31041
Thermoplastic
Fluorinated Silicone
-65°C to +175°C
It is highly recommended for the
correct installation that the dedicated
back fitting and rear grommet is
used with this connector
Plug & receptacle caps are available
No electrical or mechanical defects
after 500 cycles
As per Mil-DTL-38999
As per Mil-DTL-38999
Contacts:
Material:
Current Rating:
Type:
BENEFITS
Space saving with integral power and signal wires
Provides superior contact retention under severe vibration
Standard Mil-C-39029 contacts as used in Mil-DTL-38999
connectors
Threaded coupling with self locking mechanism for anti-vibration
Enhanced cable support and sealing
Cable Size:
Size 4:
Size 20:
Crimp Tool:
Dieset:
16mm
2
cable
25mm
2
cable
Insulators:
Interface Seal:
Temperature:
Backshell:
COMPANY QUALITY APPROVALS
Civil Aviation Authority A8-1
BS EN ISO 9001
Military Spec Approvals 38999
BS9000 and CECC
Underwriters Laboratories
With 30 years experience in designing and
manufacturing at its own facilities, Deutsch UK
can provide interconnection solutions for the
most demanding of environments
Deutsch UK
Castleham Industrial Estate
4 Stanier Road, St Leonard-On-Sea
East Sussex TN38 9RF England
Telephone +44 (0) 1424 852721
Fax
+44 (0) 1424 851726
Email
marketinguk@deutsch.net
www.deutsch.net
Protective Caps:
Durability:
Vibration:
Thermal Shock:
How does CC2530 send information to a specified terminal device? ? ?
In the past few days, I have been doing experiments with CC2530. The coordinator broadcasts or multicasts data. After the terminal node receives the data, if the coordinator sends feedback information...
HiAnt RF/Wirelessly
Does anyone need Digi Connect ME JSK?
I have a Digi Connect ME JSK, but I don't need it anymore because I'm developing for mobile phones. Is there anyone who can use it? Email: gxlam@sohu.com...
xyj_70 Embedded System
Application of 485 hub in security monitoring system
Application of 485 hub in industrial security monitoring system In the existing monitoring system, the matrix host, control keyboard host, and hard disk recorder are generally present separately in th...
dailyrfid Embedded System
I'm a novice in designing the circuit of a wireless transmitter module. Please
I am a senior student. I am working on a wireless transmission project. The premise is that the data is available and the distance is about 5 meters. It is required to connect to the computer via USB....
shilei1014 Industrial Control Electronics
Things to note when using C/C++ to write programs based on TMS320 series DSP
[size=4][font=微软雅黑, 宋体]1. Without affecting the execution speed, you can use the function library provided by C or C/C++ language, or you can design your own function, which is easier to use the "tail...
fish001 DSP and ARM Processors
avr 12864 display program
#include #define uchar unsigned char #define uint unsigned int #define EH PORTB|=1; #define EL PORTB=~1; #define RD PORTB|=(11); #define WR PORTB=~(11); #define RSL PORTB=~(12); #define RSH PORTB|=(12...
途头是道 Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2864  1637  1763  1849  267  58  33  36  38  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号