EEWORLDEEWORLDEEWORLD

Part Number

Search

WSYN-400-220-460AC-A

Description
POWER/SIGNAL RELAY, DPST, MOMENTARY, 5A (CONTACT), 28VDC (CONTACT), PANEL MOUNT
CategoryMechanical and electronic products    relay   
File Size65KB,1 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

WSYN-400-220-460AC-A Overview

POWER/SIGNAL RELAY, DPST, MOMENTARY, 5A (CONTACT), 28VDC (CONTACT), PANEL MOUNT

WSYN-400-220-460AC-A Parametric

Parameter NameAttribute value
MakerTE Connectivity
Reach Compliance Codeunknown
ECCN codeEAR99
body width127.4 mm
body height76.7 mm
Body length or diameter127.7 mm
Maximum coil voltage (AC)460 V
Contact (AC) maximum rated R load5A@120VAC
Maximum contact current (AC)5 A
Maximum contact current (DC)5 A
Contact (DC) maximum rated R load5A@28VDC
Maximum contact voltage (AC)120 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Manufacturer's serial numberWSYN
Installation featuresPANEL MOUNT
Maximum operating temperature50 °C
Minimum operating temperature-20 °C
physical size127.7mm X 127.4mm X 76.7mm
GuidelineCSA; UL
Relay actionMOMENTARY
Relay functionDPST
Relay typePOWER/SIGNAL RELAY
surface mountNO
Termination typeSCREW
Base Number Matches1
Paralleling Relays
WILMAR™ Protective Relays – WSYN Series
TERMINAL STRIPS
#6 - 32 SCREWS
Function:
25
ANSI/IEEE C37.90-1978
UL file No. E58048
CSA file No. LR61158
Operation:
A. The output relay will energize when all three
of the following conditions are met:
1. Voltage differential is below the preset
value.
2. Phase angle is below the preset value.
3. Frequency differential is below the preset
value.
B. The relay is also provided with a "Double Dead
Bus" feature: When the voltage on either one
of the sensing inputs is below 15-25% of
nominal, (Dead Bus Condition), the output
relay will energize to permit paralleling.
1 2
4 /
2
15
/
3
5
4
3
/
16
3
1
/
2
7
/
16
4
1
/
4
5
2
23
/
3
5
When both sensing voltage are below 15-25%
of nominal, the output relay will not energize.
/ DIA.
4 MTG. HOLES
13 64
"
Note:
Dimensions in inches. Multiply values by 25.4 for dimensions in mm.
PART NUMBER SELECTION
Sample Part No.
Type:
WSYN - Synchro Check
Frequency Hz
50
60
400
WSYN-50-120-12DC-A
PRODUCT SPECIFICATIONS
Part Number
Sensing Voltage ...................................
WSYN Series
Single Phase, see Part Number Selection
Sensing Voltage VAC (
±10%)
120
400
200
416
208
440
220
460
230
480
240
525
380
575
Control Voltage (
±20%)
12DC
120AC
24DC
230AC
48DC
380AC
125DC
460AC
Options
A = two normal open contacts
B = two normally closed contacts
H = Contacts rated 3 amp at 125 VDC
P = Transient Protection
Transient Protection
- All voltage relays will withstand
momentary voltage surges of twice the nominal rated input
voltage (standard).
Control Voltage .................................... See Part Number Selection
Voltage Differential Adjust Range ....... 4% to 10% of nominal voltage
Phase Angle Adjust Range .................. 4 to 10 electrical degrees
Frequency Differential Adjust Range
Operating Temperature ........................
0.2 Hz to 0.5 Hz
-20
o
C to +50
o
C
Contact Ratings .................................... 5 amp resistive at 120 VAC or 28Vdc
Output Contacts ...................................
One set N.O., one set N.C.
Notes:
1. Remove black cover screws to gain access to the adjustment potentiometers.
2. Clockwise rotation increases the trip differential setting.
3. Calibration terminals (11) (12) must be connected together to disable the phase angle
detector when setting the frequency difference trip point. Once it is set, the connection must
be removed.
38
Tyco Electronics
/ www.tycoelectronics.com / Factory Direct Technical Support: 800-253-4560, ext. 2023 (U.S., Canada, Mexico) or 805-220-2020, ext. 2023 (International)
Byte type problem
I recently saw a definition where several different variables were defined as byte data types, but the number of bytes they occupied was 1, 8, or 16. However, I checked the standard C and found no suc...
青城山下 Linux and Android
Find an overcurrent protection circuit
I designed a power supply and need an overcurrent protection circuit. Requirements: When the load is short-circuited, cut off the load. Output current <2A. Output voltage 0~9.9V [[i] This post was las...
qy08301 Power technology
Voltage regulator chip
What voltage regulator chips are generally used to obtain the reference voltage of a high-precision AD converter? The reference voltage I want is 2.5V...
小马 Embedded System
Q: LM3S9B92 ADC module
SysCtlADCSpeedSet(SYSCTL_ADCSPEED_125KSPS);Should the sampling rates of ADC0 and ADC1 be set to 125KSPS? If the two modules use different sampling frequencies, how should they be written? . .If the vo...
喜鹊王子 TI Technology Forum
Illustrated description of the 10 working processes of zero voltage switching power supply (ZVS)
Zero voltage switching power supply (ZVS) is a relatively advanced and mature technology in the current switching power supply technology. Because it is in a soft switching state, it can achieve highe...
凤舞天 Power technology
Please! Please! Please! Please! Please! Please buy a book "Tornado/VxWorks Getting Started and Advanced"
I'm learning vxworks recently. I'm a beginner and I know nothing about it. I found a book, "Tornado/VxWorks Getting Started and Advanced", which I think is very helpful to me, but I can't buy it anywh...
jiangyebula Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2365  2238  970  1540  558  48  46  20  31  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号