Base Number Matches1
3
CIRCUIT BREAKERS FOR EQUIPMENT
TA45: 3 pole, rocker actuated
• Thermal release
• Positively trip-free
The rocker actuated, 3 pole version with 2 protected poles is a
thermal CBE of the TA45 line, specifically designed to provide cost
effective protection of 3 phase motors against overheating in
accordance with EN60204 Part I (Electrical equipment for industrial
machines) in cases where the exception specified in this standard is
applicable.
A special version is available as a «CBE-switch», in which the means
for automatic overcurrent interruption (the bimetal releases), are
omitted.
Another available version of this line utilizes an under-voltage release
to protect persons against injuries caused by unexpected events like
the automatic restarting of motors after a power failure. This release
can be combined with the thermal release required for overcurrent
protection. Protection against injuries is also provided by another CBE
of this line, which prevents the starting of a machine should a
protective cover be removed from dangerous parts of the machine.
Available options:
• CBE for overcurrent protection
2 protected poles (thermal)
• CBE with undervoltage release:
The CBE will open automatically when the voltage drops
below the trip level. Only when the supply voltage has reached
the reset level, the CBE can be re-closed manually.
• CBE switch with mechanical lock-out latch:
A spring loaded pin will trip the CBE if a protective cover is
removed. The CBE can not be switched ON until the
protective cover is refitted.
• CBE with remote trip release:
The remote trip release permits the CBE to be tripped by a
external contact (sensor) energizing the trip coil.
• CBE with auxiliary contact:
All types of the line can be with an auxiliary contact
(changeover contact).
TA45 is positively trip-free. The approved current range is 0,1 to 12A.
We recommend to limit the current range to max. 8A at AC 400V.
For the current range 9 to 12A the voltage should be limited to AC
240V. The CBE comes with snap-in mounting. The rocker is available
in various colors and also with illumination. It is approved in all major
industrial countries and complies with the CBE-standard EN60934. In
conjunction with its accessories the TA45 product line of Schurter
paves the way for new unconventional applications.
Applications
Motors
Power supplies
Processing machines
etc.
254
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 •
E-mail info@schurterinc.com •
Website http://www.schurterinc.com
Phone 707-778-6311 • Fax 707-778-6401 E-mail info@schurterinc.com Website http://www.schurterinc.com
How to break the process chain and hide the process by EPROCESS address?
The article on Rootkits: Subverting the Windows Kernel describes how to achieve process hiding by hooking ZwQuerySystemInformation. It removes the process chain by judging whether the process name is ...
mfxbb Embedded System
Can applications developed under .NET Framework run under WinCE's .NET Compact Framework?
1. Our company's application was developed under Windows XP + Visual Studio 2008, mainly involving Socket communication, XML parsing, multi-threading and other related namespaces and classes, and usin...
rado3090 Embedded System
Questions about MSP430 ADC triggering DMA
[i=s]This post was last edited by 905105948 on 2017-3-17 08:57[/i] The microcontroller model is MSP430FR6972. I want to use ADC serial channel sampling, channel 0-1, trigger DMA, and store the ADC sam...
905105948 Microcontroller MCU
Embedded real-time operating system tutorial.
Embedded Real-Time Operating System Tutorial....
daicheng Embedded System
The construction of the high voltage base for power transmission and transformation test officially started
In Henan Province of China, a high-voltage transmission and transformation test base is under construction, which means that the safety level of China's power grid in testing, identifying and repairin...
xsappleone Talking
How to implement pseudo-random number function on stm32f103
Recently, I was working on a wired gateway and needed to generate a string of random numbers on the stm32f103 platform as a LAN authentication token. Unlike f2 and f4, stm32f103 does not have a random...
wateras1 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 591  1792  741  344  2510  12  37  15  7  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号