31-2.125-182A

Description
Wire And Cable
CategoryThe connector    Connector bracket   
File Size286KB,3 Pages
ManufacturerAries Electronics
Download Datasheet Parametric View All

31-2.125-182A Overview

Wire And Cable

31-2.125-182A Parametric

Parameter NameAttribute value
MakerAries Electronics
Reach Compliance Codecompliant
ECCN codeEAR99
Connector bracket typeWIRE AND CABLE
Base Number Matches1
Series 181 Thru 183
90° Pin Staked Flex Jumpers
FEATURES:
• Aries 90° Pin Staked Flex Jumpers combine thin, flexible, solid Copper conductors
embedded between layers of tough, flexible, flame-retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See Data Sheet
11005
for Flat Pin Staked Flex Jumpers
• For RoHS applications for Lead-Free Soldering use HT Cable
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant Polyester
(Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide (Kapton) insulation
with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equivalent to that
of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min. Nickel per
ASTM-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over 50μ”
[1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps
• Cable voltage rating=300 Volts
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp)
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp)
•Conductor/Contact Resistance (avg.) = 20mOhms initial (max. 20mOhm increase)
based on a 2”cable @20°C.
•Operating temperature=67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square,
.150 [3.81] long minimum.
MOUNTING CONSIDERATIONS:
• Suggested PCB hole size=.032+ .002 .81 + .05] dia.
No. of Conductors:
(4 – 40)
Note: Aries specializes in custom design and production. In addition to
the standard products shown on this page, special materials, platings,
sizes, and configurations can be furnished, depending on quantities.
Aries reserves the right to change product specifications without notice.
A
LL DIMENSIONS
:
INCHES
[
MILLIMETERS
]
All tolerances
+ .005 [.13] unless otherwise specified
Kapton is a registered trademark for DuPont
**Aries reserves the right to ship with
or without a polarization stripe unless
otherwise specified by customer
“A”=NO. OF CONDUCTORS X .100 [2.54]
“B”=(NO. OF CONDUCTORS -1) X .100 [2.54]
ORDERING INFORMATION
XX-XXXX-18X X X XX XX
Optional Suffix:
“HT”=High temperature cable insulation
Optional Suffix:
“TL” = Tin/Lead Plating
Optional Suffix:
“P”=Polarization stripe included
Cable Length: “L” in inches
Min. Cable Length = 2.00” (-002)
2” = -002-
2.5” = -002.5-
2.25” = -002.25-
2.125” = -002.125-
Jumper Series:
181: Male both ends
182: Male/Female (tin)
183: Female (tin) both ends
Bend Options:
“A” = Both ends bent 90°, same direction
“B” = One male end bent 90°
“C” = Both ends bent 90°, opposite direction
“D” = One female end bent 90°
XX-XXXX-182B
XX-XXXX-182BP
XX-XXXX -182BTL
XX-XXXX-182BHT
XX-XXXX-182BPTL
XX-XXXX-182BPHT
XX-XXXX-182BPTLHY
XX-XXXX-182C
XX-XXXX-182CP
XX-XXXX-182CTL
XX-XXXX-182CHT
XX-XXXX-182CPTL
XX-XXXX-182CPHT
XX-XXXX-182CPTLHT
XX-XXXX -182D
XX-XXXX-182DP
XX-XXXX-182DTL
XX-XXXX-182DHT
XX-XXXX-182DPTL
XX-XXXX-182DPHT
XX-XXXX-182DPTLHT
XX-XXXX-183A
XX-XXXX-183AP
XX-XXXX-183ATL
XX-XXXX-183AHT
XX-XXXX-183APTL
XX-XXXX-183APHT
XX-XXXX-183APTLHT
XX-XXXX-183C
XX-XXXX-183CP
XX-XXXX-183CTL
XX-XXXX-183CHT
XX-XXXX-183CPTL
XX-XXXX-183CPHT
XX-XXXX-183CPTLHT
XX-XXXX-183D
XX-XXXX-183DP
XX-XXXX-183DTL
XX-XXXX-183DHT
XX-XXXX-183DPTL
XX-XXXX-183DPHT
XX-XXXX-183DPTLHT
XX-XXXX-181A
XX-XXXX-181AP
XX-XXXX-181ATL
XX-XXXX-181AHT
XX-XXXX-181APTL
XX-XXXX-181APHT
XX-XXXX-181APTLHT
XX-XXXX-181B
XX-XXXX-181BP
XX-XXXX-181BTL
XX-XXXX-181BHT
XX-XXXX-181BPTL
XX-XXXX-181BPHT
XX-XXXX-181BPTLHT
XX-XXXX-181C
XX-XXXX-181CP
XX-XXXX-181CTL
XX-XXXX-181CHT
XX-XXXX-181CPTL
XX-XXXX-181CPHT
XX-XXXX-181CPTLHT
XX-XXXX-182A
XX-XXXX-182AP
XX-XXXX-182ATL
XX-XXXX-182AHT
XX-XXXX-182APTL
XX-XXXX-182APHT
XX-XXXX-182APTLHT
http://www.arieselec.com • info@arieselec.com
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
Bristol, PA
USA
TEL:
(215) 781-9956
FAX:
(215) 781-9845
11019
REV.K
Page
1 of 3
Design of indoor sports assessment system
After the signal is successfully sent and received, it should be relatively easy to display the temperature and humidity in real time. However, it is a bit troublesome to draw the corresponding motion...
yueyuanque Wireless Connectivity
There are 169 holidays in 2017. Do you PCB design engineers believe it?
Original 169 days of holidays and rest days. Don’t say you don’t believe it. So I searched on the Internet. It is a certain fact that 26 days of statutory holidays, but where do the 169 days come from...
kdyhdl PCB Design
Good permanent magnet synchronous motor design
Dear experts:Are there any good permanent magnet synchronous DC motor design solutions and templates? Better details can be paid...
liuyi160 Circuit Observation Room
PCB cannot be wired manually
When manually routing the pins of a Bluetooth module chip, the middle TX3 pin cannot be routed? Can anyone tell me if you know? Thank you!...
ben007sky2003 PCB Design
Regarding the data transmission format in serial communication
During the serial communication, I use PC to send data to MCU. On the transmission line, these data are transmitted at their corresponding levels. When the data is inside the MCU, someone told me that...
1157421908 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1444  593  1572  1111  1601  30  12  32  23  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号