1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation
of the device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability.
SIMPLIFIED SCHEMATIC, EACH
SWITCH
ONE OF TWO 1:4 MUX/DEMUX BANKS
Inputs
OE
L
L
L
L
H
NOTE:
1. H = HIGH Voltage Level
L = LOW Voltage Level
X = Don't Care
FUNCTION TABLE
(1)
S1
L
L
H
H
X
S0
L
H
L
H
X
Function
A Port = B1 Port
A Port = B2 Port
A Port = B3 Port
A Port = B4 Port
Disconnect
A
B
CONTROL
CIRCUITRY
OPERATING CHARACTERISTICS, T
A
= 25°C
(1)
Symbol
V
CC
V
IH
V
IL
T
A
Parameter
Supply Voltage
High-Level Control Input Voltage
Low-Level Control Input Voltage
Operating Free-Air Temperature
V
CC
= 2.3V to 2.7V
V
CC
= 2.7V to 3.6V
V
CC
= 2.3V to 2.7V
V
CC
= 2.7V to 3.6V
NOTE:
1. All unused control inputs of the device must be held at V
CC
or GND to ensure proper device operation.
Test Conditions
Min.
2.3
1.7
2
—
—
−40
Max.
3.6
—
—
0.7
0.8
85
Unit
V
V
V
°C
2
IDT74CBTLV3253
LOW-VOLTAGE DUAL 1-OF-4 MULTIPLEXER/DEMULTIPLEXER
INDUSTRIAL TEMPERATURE RANGE
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Operating Conditions: T
A
= –40°C to +85°C
Symbol
V
IK
I
I
I
OZ
I
OFF
I
CC
ΔI
CC
(2)
C
I
C
IO(OFF)
Control Inputs
Control Inputs
A Port
B Port
V
CC
= 2.3V
Typ. at V
CC
= 2.5V
Parameter
Control Inputs, Data Inputs
Control Inputs
Data I/O
V
CC
= 3V, I
I
= –18mA
V
CC
= 3.6V, V
I
= V
CC
or GND
V
CC
= 3.6V, V
O
= 0 or 3.6V, switch disabled
V
CC
= 0, V
I
or V
O
= 0 to 3.6V
V
CC
= 3.6V, I
O
= 0, V
I
= V
CC
or GND
V
CC
= 3.6V, one input at 3V, other inputs at V
CC
or GND
V
I
= 3V or 0
V
O
= 3V or 0,
OE
= V
CC
= 3.3V
V
I
= 0
V
I
= 1.7V
V
I
= 0
V
CC
= 3V
V
I
= 2.4V
I
O
= 64mA
I
O
= 24mA
I
O
= 15mA
I
O
= 64mA
I
O
= 24mA
I
O
= 15mA
Test Conditions
Min.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Typ.
(1)
—
—
—
—
—
—
4
20
6
5
5
27
5
5
10
Max.
–1.2
±1
5
50
10
300
—
—
—
8
8
40
7
7
15
Unit
V
µA
µA
µA
µA
µA
pF
pF
R
ON
(3)
Ω
NOTES:
1. Typical values are at V
CC
= 3.3V, +25°C ambient.
2. The increase in supply current is attributable to each current that is at the specified voltage level rather than V
CC
or GND.
3. This is measured by the voltage drop between the A and B terminals at the indicated current through the switch. On-state resistance is determined by the lower of the voltages
of the two (A or B ) terminals.
SWITCHING CHARACTERISTICS
V
CC
= 2.5V ± 0.2V
Symbol
t
PD
(1)
t
SEL
t
EN
t
DIS
Parameter
Propagation Delay
A to B or B to A
Select Time
S to A or B
Enable Time
S to B
Disable Time
S to B
t
EN
t
DIS
Output Enable Time
OE
to A or B
Output Disable Time
OE
to A or B
NOTE:
1. The propagation delay is the calculated RC time constant of the typical on-state resistance of the switch and the specified load capacitance driven by an ideal voltage source
(zero output impedance).
V
CC
= 3.3V ± 0.3V
Max.
0.15
4.8
4.8
5.1
Min.
−
1
1
1
Max.
0.25
4.5
4.5
5.3
Unit
ns
ns
ns
ns
Min.
−
1
1
1
1
1
5
5.5
1
1
4.8
5.4
ns
ns
3
IDT74CBTLV3253
LOW-VOLTAGE DUAL 1-OF-4 MULTIPLEXER/DEMULTIPLEXER
INDUSTRIAL TEMPERATURE RANGE
TEST CIRCUITS AND WAVEFORMS
TEST CONDITIONS
Symbol
V
LOAD
V
IH
V
T
V
LZ
V
HZ
C
L
V
CC(1)
= 3.3V±0.3V
6
3
1.5
300
300
50
V
CC(2)
= 2.5V±0.2V
2 x Vcc
Vcc
Vcc / 2
150
150
30
Unit
V
V
V
mV
mV
pF
SAME PHASE
INPUT TRANSITION
t
PLH
OUTPUT
t
PLH
OPPOSITE PHASE
INPUT TRANSITION
t
PHL
t
PHL
V
IH
V
T
0V
V
OH
V
T
V
OL
V
IH
V
T
0V
Propagation Delay
V
CC
500Ω
Pulse
Generator
(1, 2)
V
LOAD
Open
GND
CONTROL
INPUT
ENABLE
DISABLE
V
IN
D.U.T.
R
T
V
OUT
t
PZL
OUTPUT
SWITCH
NORMALLY
CLOSED
LOW
t
PZH
OUTPUT
SWITCH
NORMALLY
OPEN
HIGH
V
LOAD/2
V
T
t
PHZ
V
T
0V
t
PLZ
V
IH
V
T
0V
V
LOAD/2
V
OL +
V
LZ
V
OL
V
OH
V
OH -
V
HZ
0V
500Ω
C
L
Test Circuits for All Outputs
Enable and Disable Times
DEFINITIONS:
C
L
= Load capacitance: includes jig and probe capacitance.
Wireless Sensor Network Report - RSSI Measurement and Its Relationship with Distance 1. Experimental Purpose l Study the quantitative relationship between transmission power, transmission distance, re...
Abstract: This paper introduces the design idea of a multi-network intelligent remote control system which is based on the single-chip microcomputer AT89C52, dual-tone multi-frequency decoding integra...
The following is the MISRA constraint on the use of unions in the "Embedded C Standard Research Report" [color=#0000FF] Rule 18.4 does not allow the use of unions. This is an unreasonable rule. Before...
Let's take a look at what the FPU is capable of with a simple example !Environment description: Select LM3S9B96 for CORTEX M3 under KEIL simulation
Test requirement: Calculate 1 * 0.5
#define T20
#def...
introduction
In the discharge process of tokamak plasma physics, the study of rupture and sawtooth is of great significance. Rupture and sawtooth exist in most tokamaks. Rupture is a notew...[Details]
A standard cell
is an electrochemical
cell
used as a voltage reference standard in many electrical standards laboratories
. If properly maintained, standard cells are very stable. The ...[Details]
1. Background:
The instrument system parameter detection and control of the chemical production workshop of Tangshan Coal Gas Coking Plant are all analog instruments, some of which are eve...[Details]
1. Overview
The Virtual CAN Interface (VCI) function library is an application program interface specifically provided for the use of ZLGCAN devices on PCs. The functions in the library ar...[Details]
Product series: PB-B-RS232/485 interface (hereinafter sometimes referred to as "interface") is a product in the PROFIBUS bus bridge series.
The main purpose of the bridge series ...[Details]
1. Project Introduction
Shandong Dezhou Xingtai Paper Co., Ltd. is a newly built high-end paperboard production enterprise with domestic leading level established by Shandong Zhaodongfang Pape...[Details]
hint:
The number of speakers and their spacing limit the sound field of a portable stereo system.
Spatial audio attempts to artificially recreate the experience of listening to sounds i...[Details]
1 Basic Features
In computer control systems and various intelligent instruments and meters composed of single-chip microcomputers (or microprocessors), various external analog signals must be ...[Details]
The emergence and development of street lamps are inseparable from the prosperity and progress of cities, which makes street lamps useful. Conversely, street lamps also make the night of the city n...[Details]
The most important components of new energy electric vehicles are power batteries, electric motors and energy conversion control systems. The power battery must achieve high performance such as fas...[Details]
Features
POE technology can ensure the safety of existing structured cabling while ensuring the normal operation of the existing network and minimizing costs. The IEEE 802.3af standard is ...[Details]
Dual Tone MultiFrequency (DTMF) signaling is gradually being used in push-button telephones around the world. It quickly replaced the dial pulse signaling used in traditional rotary phones because ...[Details]
Designing low power circuits while achieving acceptable performance is a difficult task. Doing so in
the RF
bands increases the challenge dramatically. Today, nearly everything has wireless...[Details]
Some people think: as long as the program runs well, it doesn't matter how the original program is written. But this is absolutely not the case. Software is not completed in one go, and it is neces...[Details]
Voltage hysteresis is a characteristic of lithium-ion battery and the basis of its existence. The principle is as follows: the thionyl chloride electrolyte of the battery is a strong oxidizing chem...[Details]