EEWORLDEEWORLDEEWORLD

Part Number

Search

55A0831-22-3/6/9

Description
55A0831-22-3/6/9
CategoryWire/cable   
File Size24KB,1 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric Compare View All

55A0831-22-3/6/9 Overview

55A0831-22-3/6/9

55A0831-22-3/6/9 Parametric

Parameter NameAttribute value
Cable typeSpec 55A
Rated voltage (VAC)600
Insulation MaterialsIrradiation cross-linked modified ETFE
conductor materialtinned copper, tinned copper
Wire size (AWG)22
Wire size (mm²).33
range of working temperature-65 – 150 °C [ -85 – 302 °F ]
SPECIFICATION CONTROL DRAWING
Title
SCD
55A0831
Revision
Date
THREE CONDUCTOR CABLE, UNSHIELDED, UNJACKETED,
1-13-17
GENERAL PURPOSE, 600 VOLT
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
D
COMPONENT WIRES - 55A0811
CABLE CONSTRUCTION DETAILS
CONDUCTOR
SIZE
(AWG)
26
24
22
20
18
16
14
12
10
8
6
4
OUTSIDE DIAMETER
(inch)
NOMINAL
55A0831-26-*
55A0831-24-*
55A0831-22-*
55A0831-20-*
55A0831-18-*
55A0831-16-*
55A0831-14-*
55A0831-12-*
55A0831-10-*
55A0831-8-*
55A0831-6-*
55A0831-4-*
.086
.097
.108
.125
.151
.166
.203
.240
.289
.421
.521
.670
MAXIMUM
.091
.102
.112
.130
.158
.173
.210
.246
.298
.438
.542
.691
5.2
7.0
9.8
14.4
22.0
27.5
42.2
62.7
99.1
185.
289.
459.
MAXIMUM
WEIGHT
(lbs/1000 ft.)
PART NUMBER
1/
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz
INSULATION FLAWS:
Spark Test, 5.7 kV (rms) at 3 kHz
Impulse Dielectric Test, 8.0 kV (peak)
1/ PART NUMBER:
The "*" in the part numbers above shall be replaced
by color code designators with a slash separating the
component wire colors. Colors shown do not
necessarily reflect the sequence of manufacturing.
Example: AWG 22, orange, blue, and white component
wires: 55A0831-22-3/6/9
NOTE: Nominal values are for information only. Nominal values are not requirements.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902..." MAY BE REPLACED BY "Axxx".) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks.
Page 1 of 1
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-522-6752
Fax: 1-650-361-6297
© 2009-2017 Tyco Electronics Corporation. All rights reserved.

55A0831-22-3/6/9 Related Products

55A0831-22-3/6/9 55A0831-20-3/6/9 55A0831-20-9/93/96CS2275 55A0831-16-3/6/9 55A0831-24-9/93/96CS2275 55A0831-12-MST3CS2275 55A0831-16-9/93/96CS2275
Description 55A0831-22-3/6/9 55A0831-20-3/6/9 55A0831-20-9/93/96CS2275 55A0831-16-3/6/9 55A0831-24-9/93/96CS2275 55A0831-12-MST3CS2275 55A0831-16-9/93/96CS2275
Rated voltage (VAC) 600 600 600 600 600 600 600
Insulation Materials Irradiation cross-linked modified ETFE Irradiation cross-linked modified ETFE Irradiation cross-linked modified ETFE Irradiation cross-linked modified ETFE Irradiation cross-linked modified ETFE Irradiation cross-linked modified ETFE Irradiation cross-linked modified ETFE
conductor material tinned copper, tinned copper tinned copper, tinned copper tinned copper, tinned copper tinned copper, tinned copper tinned copper, tinned copper tinned copper, tinned copper tinned copper, tinned copper
Wire size (AWG) 22 20 20 16 24 12 16
Wire size (mm²) .33 .52 .52 1.31 .21 3.31 1.31
range of working temperature -65 – 150 °C [ -85 – 302 °F ] -65 – 150 °C [ -85 – 302 °F ] -65 – 150 °C [ -85 – 302 °F ] -65 – 150 °C [ -85 – 302 °F ] -65 – 150 °C [ -85 – 302 °F ] -65 – 150 °C [ -85 – 302 °F ] -65 – 150 °C [ -85 – 302 °F ]
Cable type Spec 55A Spec 55A Spec 55A Spec 55A Spec 55A Spec 55A primary
Verilog HDL exercises and Verilog basics suitable for newcomers to Verilog.rar
Verilog HDL exercises and Verilog basics are suitable for Verilog beginners135 classic design examples of Verilog...
493025560 FPGA/CPLD
Comparison between Altium Designer 14 and 10
[p=22, null, left][color=#4d4b4b][font=宋体, Arial, Helvetica, sans-serif]Author: Zhu Changjiang[/font][/color][/p][p=22, null, left][color=#4d4b4b][font=宋体, Arial, Helvetica, sans-serif] Altium Designe...
qwqwqw2088 PCB Design
Discussion on EMI rules for high-speed PCB design (Part 2)
[size=2]Rule 5: Routing direction rules for high-speed PCB design The routing between two adjacent layers must follow the principle of vertical routing, otherwise it will cause crosstalk between lines...
心仪 PCB Design
There is no LM5117 in the Multisim14.0 simulation library
Where can I download the schematic library of LM5117?...
激射电火花 Electronics Design Contest
LCD 1602 display source code
LCD 1602 display source code #includereg52.h#define uint unsigned int#define uchar unsigned charsbit en=P2^0;sbit rs=P2^1;uchar code table[]="I LOVE YOU";uchar code table1[]="FOREVER MAMA!";uchar num;...
guoyuanqiang MCU
Program Jump
void send (uchar n) {SBUF=n;while(!IF) ;IF=0; }void main() {SP=0x30;init_cpu(); //This function sets up serial communicationwhile(1){send(0x01);P1=0x01;send(0x02);P1=0x02;send(0x03);P1=0x03;send(0x04)...
scorpius 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 298  2330  1363  1910  1094  6  47  28  39  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号