EEWORLDEEWORLDEEWORLD

Part Number

Search

3120-F521-H7T1-W01D-10A

Description
2 POLE(S), 10A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,
CategoryCircuit protection    Circuit protection   
File Size2MB,16 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Download Datasheet Parametric View All

3120-F521-H7T1-W01D-10A Online Shopping

Suppliers Part Number Price MOQ In stock  
3120-F521-H7T1-W01D-10A - - View Buy Now

3120-F521-H7T1-W01D-10A Overview

2 POLE(S), 10A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,

3120-F521-H7T1-W01D-10A Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
Actuator typeROCKER
body width21 mm
body height33 mm
Body length or diameter48 mm
circuit functionMANUAL ON/OFF
Circuit protection typeTHERMAL CIRCUIT BREAKER
Environmental characteristicsCORROSSION RESISTANT
Installation featuresPANEL MOUNT
Number of poles2
Maximum operating temperature60 °C
Minimum operating temperature-30 °C
physical size48mm x 21mm x 33mm
Rated breaking capacity100 A
Rated current10 A
Rated voltage (AC)250 V
Rated voltage (DC)50 V
GuidelineCCC; CSA; UL; VDE
surface mountNO
Terminal shapeQUICK CONNECT
Base Number Matches1
Thermal Circuit Breaker 3120-F...
Description
The 3120 circuit breaker/switch combination is an ON/OFF switch
with integral overcurrent protection (S-type TO CBE to EN/IEC
60934). The trip element is a bimetal. Type 3120 is ideally suited for
overload protection of motors, pumps, transformers and cables.
The 3120 circuit breaker is also available as a switch-only version in
accordance with the IEC/EN 61058 (see data sheet switch 3120-F-..Q1).
Product characteristics:
l
rocker or push button actuation
l
single pole and double pole versions
l
reliable switching behaviour (positively trip-free)
l
convenient snap-in mounting
l
international approvals
Options and add-on modules:
illumination
l
water splash protection
l
auxiliary contacts
l
under voltage trip
l
remote trip
l
magnetic trip
l
push-in terminals
l
appliance inlet module
l
1
Technical data
For details please see Technical information
Rated voltage
Current rating range
AC 240 V, DC 50 V
0.1...20 A
(up to 30A upon request for single pole
units)
30,000
30,000
30,000
30,000
operations
operations
operations
operations
at
at
at
at
at
at
at
at
1
1
1
1
1
1
1
1
x
x
x
x
x
x
x
x
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
inductive
inductive
resistive
inductive
inductive
inductive
inductive
inductive
Typical applications
Medical and laboratory equipment, apparatus and machine
construction, professional tools, household and garden appliances,
offices machines, audio equipment, machine tools
Typical life 1-pole
0.1...20 A
0.1...4 A
4.5...16 A
DC 28 V:
0.1...20 A
Typical life 2-pole
AC 240 V:
AC 240 V:
DC 50 V:
Current ratings and internal resistance values
Current rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current rating
(A)
4
4.5
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance
per pole (Ω)
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
0.1...16 A 50,000 operations
17...20 A 30,000 operations
DC 50 V:
0.1...16 A 50,000 operations
17...20 A 50,000 operations
Ambient temperature
-30 … 60 °C
Insulation coordination
(IEC 60664)
Dielectric strength
Operating area
pole to pole (2-pole)
Insulation resistance
Interrupting capacity I
cn
2.5 kV /2 reinforced insulation at
operating area
test voltage AC 3,000 V
test voltage AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2 A
10 x I
N
2.5...20 A
1-pole 150 A
2-pole 250 A
Interrupting capacity (UL 1077)
I
N
1-pole, 2- pole
1-pole, 2- pole
0.1...20 A
0.1...20 A
U
N
AC 250 V
DC 50 V
I
nc
5000 A, C, 1
1000 A, C, 1
Degree of protection
(IEC 60529)
Vibration
Current consumption of illumination
Operating voltage
DC 12 V
DC 24 V
DC 48 V
AC 115 V
AC 230 V
Current consumption
Y
5.2 mA
4.5 mA
4.5 mA
2.8 mA
2.2 mA
R
2 mA
2.2 mA
2 mA
1.1 mA
0.9 mA
G
1.4 mA
1.6 mA
1.6 mA
1 mA
0.9 mA
Shock
Corrosion
Humidity
Mass
operating area IP40
terminal area IP00
with water splash cover IP54 or IP66
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
test to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
test to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
test to IEC 60068-2-11, test Ka
240 hrs in 95 % RH
test to IEC 60068-2-78,
test Cab
approx. 33 g (2-pole)
approx. 27 g (1-pole)
approx. 42 g (2-pole with PT terminals)
1806
www.e-t-a.de
1
Basic knowledge of soft starter application
1. What is a soft starter? What is the difference between it and a frequency converter? A soft starter is a novel motor control device that integrates motor soft starting, soft stopping, light load en...
咖啡不加糖 Industrial Control Electronics
All information about dot matrix clock
/*;******************************************************************************** ;Program name: festiva24_table(). ;Function: Solar term database (a two-dimensional database, 24 superscripts, 4 sub...
liwenjiefa98 MCU
HP8712ET/E4407B/HP8711B/TDS3014/HP8713B/HP8711C/13168727426
E4407B   Spectrum Analyzer 10HZ-26.5GHZ   Agilent HP8751A  Network Analyzer  5HZ-500MHZ   HP HP8753A Network Analyzer 300KHZ-3GHZ  HP HP8753ES  Network Analyzer 30KHZ-3GHZ  H HP8753D  Network Analyzer...
pygao280 Embedded System
The MegaCore Function in DSP builder has nothing.
There is no IP core in the MegaCore Function in DSP builder, but there is IP in the installed Quartus. How can I add the IP core in DSPbuilder? DSPbuilder is installed correctly because the sine wave ...
ljjshuishou FPGA/CPLD
STM8207 PA1 and PA2 are not working smoothly
I am using PA1 and PA2 of STM8207 as output pins, but I found that these pins are not controlled. These pins are also the input and output pins of external crystals, but in our system, no external cry...
owentangye stm32/stm8
Can the pulsating DC be directly input into the three-phase inverter bridge without filtering after rectification?
[b]As the title says, in a frequency converter, is it possible to directly input the pulsating DC into the three-phase inverter bridge without filtering after rectification? [/b]...
huahua123 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2331  832  417  1314  2306  47  17  9  27  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号