5145.ABTWFJ16C0.211

Description
Mains Power Connector, 2A, 125/250VAC, Male,
CategoryThe connector    The connector   
File Size524KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

5145.ABTWFJ16C0.211 Overview

Mains Power Connector, 2A, 125/250VAC, Male,

5145.ABTWFJ16C0.211 Parametric

Parameter NameAttribute value
MakerSCHURTER
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARDS: IEC/EN 60950; UL 94V-0; CSA; VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN COPPER
Contact completed and terminatedTIN
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3
MIL complianceNO
Power Connector Ratings2A, 125/250VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Total number of contacts3
Base Number Matches1
POWER ENTRY MODULES /
GERÄTESTECKER-KOMBIELEMENTE
Power entry module Type 5145
– Panel mount: screw-on version, front-side
– Appliance inlet, circuit breaker type TA 45 and line filter
5145
Standard or
Medical filter
50
75
100
Characteristics
• Circuit breaker with line switch, 2-pole, non-illuminated or
illuminated
• Combined with thermal overload protection
• Optional with undervoltage- or remote trip release
• All single elements wired
Unwired versions available on request
Technical data
Rated voltage
Rated currents I
n1
)
125/250 VAC; 50/60 Hz
1–10 A; @T
a
40 °C; SEV, VDE, Semko
1–15 A; @T
a
40 °C; UL, CSA
0,1–10 A; VDE, see table 1
0,1–15 A; UL/CSA, see table 1
< 0,5 mA (250 V/60 Hz)
< 5 µA (250 V/60 Hz)
1,7 kVDC between L-N
2,7 kVDC between L/N-PE
–10 °C to +55 °C
10/055/21 acc. to IEC/EN 60068-1
IP 40 acc. to IEC 60529
suitable for equipment with prot. cl. I,
acc. to IEC 61140
quick-connect 6,3 x 0,8 mm
max. 8 mm
Thermoplastic, black, UL94 V–0
Filter
TA 45
Leackage current, Standard
Medical
Test voltage (2 sec)
Allowable ambient air
temperatures T
a
Climatic category
Degree of protection (front-side)
Protection class
Terminals
Panel thickness s
Materials: Housing
Appliance-inlet
acc. to. IEC/EN 60320-1/C14,
Protection class I, pin-temperature 70 °C
(cold condition)
Circuit breaker
acc. to IEC/EN 60934, UL 1077,
type TA45
CSA 22.2 no. 235.
2-pole rocker switch, illuminated or
non-illuminated.
Optional with undervoltage- or remote
trip release
Short circuit capacity Icn:
at In < 3 A / 240 VAC: 10 x In
at In
3 A / 240 VAC: 300 A
Line filter, standard and medical acc. to. IEC 60939, EN 133 200,
UL 1283, CSA C 22.2 no. 8
Technical details see page 202
Application note
The rated current of the line filter must be equal or higher than the
rated current of the circuit-breaker.
1)
126
www.schurter.com
[EasyARM-RT1052 Review] + Serial port idle reception to implement modbus host
[font=微软雅黑][size=4]The board does not have a 485 interface, so it can only be simulated through the serial port. The serial port resources are relatively rich, and the board has reserved several chann...
ID.LODA NXP MCU
Via Design
In ordinary PCB design, for 1-4 layer PCB design, it is generally better to use 0.36mm/0.16mm/1.02mm (drilling/pad/power isolation area) vias, but the problem is that such vias are too small and canno...
ckx提问 PCB Design
Command line parameters argc, argv in C language
main( int argc, char ** argv ) argv: pointer to pointer argc: integer char **argv or char *argv[] or char argv[][] In order to illustrate the meaning of these two parameters vividly, let us first use ...
jxb01033016 Programming Basics
How to write a very accurate delay program in C language
In the 51 series, when writing programs in assembly language, it is very convenient when a very accurate delay is required. But when using C language, it seems that you have to slowly try through the ...
heningbo MCU
Is there anyone who uses FPGA to implement framBuffer?
Embed a framebuffer similar to that in Linux in FPGA to control LCD. To let LCD display something, just fill in the corresponding unit of framebuffer with data. Has anyone done something similar?...
wonderglass FPGA/CPLD
wince6.0 mass storage device
[color=#FF0000]My USBFN is connected via ActiveSync without any problems[/color], but problems will occur when it is changed to mass storage. When USBFN is connected to the computer taskbar, the USB d...
pdh716 Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1997  97  917  508  1927  41  2  19  11  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号