EEWORLDEEWORLDEEWORLD

Part Number

Search
 PDF

342A138-4-0

Description
342A138-4-0
CategoryWire/cable   
File Size856KB,17 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

342A138-4-0 Online Shopping

Suppliers Part Number Price MOQ In stock  
342A138-4-0 - - View Buy Now

342A138-4-0 Overview

342A138-4-0

342A138-4-0 Parametric

Parameter NameAttribute value
Molded part shape45° side dividing line point
Molded Part Typetransfer
size code38
Number of branches/legs2
Material system code10
Adhesive pre-coatedno
colorblack
Transfer typeY-shaped transfer
MaterialPolyolefin elastic modification
SoftnessFlexible
Material code4
Inner diameter range (body) (mm)25.4 – 55.6
Inside diameter range (body) (in)1 – 2.19, 1 – 2.19
Inner diameter range (foot 1)12.4 – 26.9 mm [ .49 – 1.06 in ]
Inner diameter range (foot 2)12.4 – 26.9 mm [ .49 – 1.06 in ]
range of working temperature-55 – 135 °C [ -67 – 275 °F ]
Power cable accessoriesno
Meet government qualificationsno
Cable outer diameter (mm)7, 8, 9
Cable outer diameter (in).28, .31, .35
Cable main branch outer diameter (mm)3.5, 4, 4.5
Cable main branch outer diameter (in).14, .16, .18
Cable small branch outer diameter (mm)3.5, 4, 4.5
Cable small branch outer diameter (in).14, .16, .18
Fluid/Chemical Resistanceoccasional exposure to liquids
special requirementsflame retardant
Adhesive optionsS1017 separate application adhesive, S1048 separate application adhesive
Adhesive typeAdhesive purchased separately
tap angle45
CommentPlease contact Raychem for more information on adhesives and/or cut-off guard lengths
Adhesive codeS1125
c# DDE (Dynamic Data Exchange) client program, how to set up Server and Topic
As the title says. Since DDE is a very old technology, it has been replaced by OPC. But some things still need DDE. .net no longer supports DDE. Fortunately, I found a packaged API. The following is a...
ziyangcao Embedded System
LPC800-mini does not seem to be able to use Mbed
I tried to compile an Mbed program for LPC812 and changed the CPU to LPC810. The error message after compilation is as follows:It seems that there is not enough space to put the compiled code....
dcexpert NXP MCU
Will the simple setting cause assignment errors?
As the title says, in the ADS1.2 project settings, I set linktype to simple, RO Base: 0x30008000 (I checked, this address should be correct), but when assigning values to structure variables, errors a...
gwqnet Embedded System
The difference between a programmer and an emulator
I am a beginner in microcontrollers and I don't really understand the programmer's simulator. I want to know if the simulator downloads the program to the microcontroller during simulation. Is there a...
征服 DSP and ARM Processors
MSP432 MCU realizes speech recognition technology
In a world where everything is connected, more and more electronic devices that can understand speech are coming into our sight. In devices such as smartphones, tablets and laptops with Siri or Cortan...
Jacktang Microcontroller MCU
Single button control start/stop in S7-200 programming
Single button control start/stop Normally, the external device controlled by PLC must have at least one start and one stop button as input signals to control the running and stopping of the program, s...
bianpinqi Industrial Control Electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2299  2697  2886  635  1204  47  55  59  13  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号