EEWORLDEEWORLDEEWORLD

Part Number

Search

800-020-CB2ZM6-4PD-48

Description
Interconnection Device
CategoryThe connector    The connector   
File Size501KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

800-020-CB2ZM6-4PD-48 Overview

Interconnection Device

800-020-CB2ZM6-4PD-48 Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
Series 802 Aqua Mouse Submersible
Overmolded Cordset Ordering Information
802-019, 802-022
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Series 802 Overmolded
Cordset
Two Cable Types
– Cordsets with
polyamide overmolds offer good chemical
resistance and are rated for one meter
immersion. For maximum chemical
resistance and 2500 PSI rating, choose
thermoset polyurethane overmolding.
Series 802 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing, or choose thermoset polyurethane overmold for superior strength, chemical resistance,
and 2500 PSI pressure rating.
Series 802 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
E
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
BAND-IT®
Shield Termination Band
Insulation Resistance
Operating Temperature
Immersion, Polyamide Overmold
Solvent Resistance, Polyamide Overmold
Immersion, Polyurethane Overmold
Solvent Resistance, Polyurethane Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, UL 94 V-0 Rated
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
200 megohms minimum
-30° C. to +105° C.
1 meter water immersion for 1 Hour per MIL-STD-810 Method 512
Excellent resistance to most solvents, fuels, and oils; poor resistance to Strong
acids and bipolar solvents (alcohol)
2500 psi
Excellent
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
E-19
Rev. 01-JANUARY-2010
Series 802
The values converted by STM32ADC multi-channel are not equal to the values converted by each single channel
The value of multi-channel conversion is about 0.2V smaller than that of single-channel conversion, and the more channels there are, the smaller the value is. When converting four channels, the value ...
tang_jun_001 stm32/stm8
PCB wiring question
I have a question for you seniors. Does the wiring on the PCB board have to be done according to the connection of the flying wire? Can I connect it according to my own ideas instead of following the ...
lym1210 PCB Design
Some kits on TI estore are discounted on "Black Friday"
Choros的手表29.99刀币免邮费 [table] [tr][td=4,1][color=rgb(17, 136, 153)][url=http://www.ti.com/tool/eZ430-Chronos]eZ430-Chronos[/url][/color] Options Available[/td][/tr] [tr][td]Part Number[/td][td][b]eZ430-...
wstt Microcontroller MCU
When the capacitor ages...
The life of a power supply often depends on the life of an electrolytic capacitor, but what changes occur in the characteristics of the capacitor as the electrolytic capacitor ages? Please feel free t...
leslie Discrete Device
Requirements for using IAR ETM Trace debugging features
In some cases, the application code may suddenly run away or generate an abnormal interrupt, and the cause of the problem may be difficult to find. When debugging such problems, you can consider using...
MamoYU Integrated technical exchanges
STC12C5A60S2 circuit diagram
Hope that helps!!...
lizhikui 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 493  1628  2816  1069  2363  10  33  57  22  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号