EEWORLDEEWORLDEEWORLD

Part Number

Search

81080-600C07-RB

Description
80 CONTACT(S), MALE, STRAIGHT TWO PART BOARD CONNECTOR, SURFACE MOUNT, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size1MB,8 Pages
Manufacturer3M
Websitehttp://3M.com/esd
Environmental Compliance
Download Datasheet Parametric View All

81080-600C07-RB Overview

80 CONTACT(S), MALE, STRAIGHT TWO PART BOARD CONNECTOR, SURFACE MOUNT, ROHS COMPLIANT

81080-600C07-RB Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Maker3M
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresPOLARIZED
Connector typeBOARD CONNECTOR
Contact to complete cooperationGOLD (30) OVER NICKEL (100)
Contact completed and terminatedMATTE TIN (250) OVER NICKEL (100)
Contact point genderMALE
Contact materialCOPPER ALLOY
DIN complianceNO
Filter functionNO
IEC complianceNO
JESD-609 codee3
MIL complianceNO
Manufacturer's serial number810
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of rows loaded2
OptionsGENERAL PURPOSE
Terminal pitch1.27 mm
Termination typeSURFACE MOUNT
Total number of contacts80
UL Flammability Code94V-0
Base Number Matches1
3M
4-Wall, Tripolarized Header
.050" × .100" Latch/Ejector, PTH & SMT Straight, PTH Right Angle
810 Series
• Tripolarized for robust alignment when mating to 820
series socket
• 50 mil × 100 mil halves the connector length vs. traditional
100 mil x 100 mil products
• Latching Ejector for rugged high performance applications
• Available for through hole or surfacemount attachment
• High temperature plastic for lead free surfacemount or
Paste-in-Hole soldering methods
• Four-wall shroud provides contact protection
• Contacts: 20, 26, 36, 40, 50, 60, 68, 80 and 100
• See the Regulatory Information Appendix (RIA)
in the “RoHS compliance” section of
www.3Mconnectors.com for compliance information
Date Modified: April 2, 2013
TS-0253-K
Sheet 1 of 7
Physical
Insulation:
Material: High Temperature Plastic (LCP)
Flammability: UL 94V-0
Color: Black
Contact:
Plating:
Material: Copper Alloy
Underplating: 100 µ" [2.54 mm] Nickel
Wiping Area: 30 µ" [0.76 mm] Gold
Solder Tails: Matte Tin or Tin Lead (See Ordering Information)
Marking:
3M Logo, Part Number and Orientation Triangle
Mating Compatibility: 820 Series (TS-0254)
Electrical
2.00 A, 4 Contacts Powered
0.75 A, All Contacts powered
Rating Conditions: EIA-364-070 Method 2, 30 degrees C maximum temperature
rise, 20% derated. Reference appropriate 3M Product Specification for detailed
current derating curves.
Insulation Resistance:
> 1 × 10
9
Ω at 500 V
DC
Withstanding Voltage:
500 V
RMS
at Sea Level
Current Rating:
3.00 A, 1 Contact Powered
Environmental
Temperature Rating:
-55°C to +105°C
Process Rating:
Maximum 260°C (Profile per J-STD-020C)
Moisture Sensitivity Level:
1 (per J-STD-020C)
UL File No.: E68080
3
Electronic Solutions Division
Interconnect Solutions
http://www.3Mconnectors.com
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373
What is the value after AD temperature conversion?
I am using the temperature sensor built into the S3C2410. After A/D conversion, the output is a decimal number, like 0270. I want to know how many degrees this is? How do I convert it?...
liuxing200 Embedded System
I would like to ask a question about C embedded assembly
1:Define two variables in C language:char age;int count;How to embed a section of assembly code in the program to assign values to these two variables? I am using STM8S103F.2:How to use the program to...
halien stm32/stm8
Remote video monitoring system based on A8
Remote video monitoring system based on A8...
keaaron DSP and ARM Processors
The MCU generates a sine wave through D/A. How to achieve frequency stepping? Please help!
My microcontroller is STC89C516RD+ (crystal oscillator 24MHZ). After D/A (8-bit) conversion, I get a fixed frequency sinusoidal signal, but I want it to achieve stepping. My idea is to change the dela...
shamuwhale Embedded System
Experts from eeworld, can you solve this problem?
I have simulated this circuit, and it is basically consistent with the actual test, but the problem is that the expressions of the voltage output Vo and voltage Vi that I calculated now do not seem to...
zhuxl Analog electronics
PSoC Bootloader Understanding (Refer to PSoC3), Continuously Updated...
There are two ways to implement firmware update: burning in system program and resident update program; System program burning is the tool used by managers to directly update the firmware. Flash burni...
wuyanyanke MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 244  1401  1546  2672  2376  5  29  32  54  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号