EEWORLDEEWORLDEEWORLD

Part Number

Search

4303.2536.04

Description
Mains Power Connector, 10A, 250VAC, Male, Quick Connect Terminal
CategoryThe connector    The connector   
File Size122KB,3 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

4303.2536.04 Overview

Mains Power Connector, 10A, 250VAC, Male, Quick Connect Terminal

4303.2536.04 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARD: IEC 60320-1/C14, 94V-0
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings10A, 250VAC
Manufacturer's serial numberKEC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeQUICK CONNECT
Total number of contacts3
Base Number Matches1
POWER ENTRY MODULES /
GERÄTESTECKER-KOMBIELEMENTE
Power entry module Type KEC
– Panel mount: screw-on version, front or rear-side / snap-in
version, front-side
– 3 functions: appliance inlet, fuseholder with
interchangeable fuse drawer for 5 x 20 or 6,3 x 32 mm
fuses, with or without voltage selector (step switch)
– Version with line filter/shield see page 110
KEC
Fuse drawer
Standard or
Medical
Fuse drawer
50
75
100
Socket
Characteristics
• Versions available with or without internal connections
• The fuse drawer “Fingergrip” can be removed by hand
• For added safety “Extra-Safe” fuse drawers are available
Extra-safe fuse drawers satisfy international standards for medical
equipment. The drawer can only be removed with the aid of a tool
• The fuseholder is accessible from the equipment front
• Qualified for use in equipment according to IEC/EN 60950
Technical data
Rated voltage
Rated currents
250 VAC
10 A; VDE, SEV, Semko
13 A; UL
16 A; CSA 1-pole
10 A; CSA 2-pole
> 3 kV between L-N
> 4 kV between L/N-PE
Dielectric strength
(50 Hz, 1 Min.)
Allowable ambient air
temperatures T
a
–25 °C to + 70 ºC
Degree of protection (front side) IP40 acc. to IEC 60529
Protection class
suitable for equipment with prot. cl. l,
acc. to IEC 61140
Terminals
quick-connect 4,8 x 0,8 mm/tin-plated
Panel thickness s
screw-on: max. 8 mm
snap-in: 1,5/2/2,5 mm
Materials: Housing
Thermoplastic, black, UL94 V-0
Appliance-inlet
acc. to IEC/EN 60320-1/C14,
protection class I,
pin-temperature 70 °C
(cold condition)
1- or 2-pole, shocksafe category PC2
acc. to IEC/EN 60127-6, for
fuse-links 5 x 20 or 6,3 x 32 mm
5 x 20: 2,5 W (1-pole)/2 W (2-pole) per p.
6,3 x 32: 3,15 W (1-pole)/2,5 W (2-pole)
per pole
see derating curves. Take note of the
information on page 195
optional,
step switch, 2–4 positions
Fuseholder
Rated power acceptance at
ambient air temp. T
a
23 ºC
Admissible power acceptance
at higher T
a
Voltage selector
www.schurter.com
53
LM3S6911 serial port 1 can enter interrupt, but serial port 2 cannot? Is there something else to set for serial port 2? ?
I am experimenting with LM3S6911 serial port 1 and serial port 2. Serial port 1 can enter the interrupt, but serial port 2 cannot. I changed all USART1 in the program to USART2, enabled the correspond...
caoqing Microcontroller MCU
Simulation software selection
Dear experts, I want to use software to simulate the discrete device Mosfet circuit. I don't know if there is any software that can correspond to the actual device when selecting the device, or whethe...
solitary Discrete Device
EMI Control in Real-World Printed Circuit Board Design (First Six Chapters)
If you want to learn, you can read the first half....
hexinzhou PCB Design
μC/OS-II Reference Manual
μC/OS-II Reference Manual (English version)...
sssls2008 Embedded System
Drive circuit
Use DSP to generate PWM waveform (two complementary waveforms), use a boost circuit to drive KD301. As a result, the voltage of the waveform is completely pulled down as soon as it is connected. KD301...
doc Industrial Control Electronics
Analysis and Research on GSM Mobile Phone Radio Frequency System (I)
The GSM digital mobile communication system was designed by a standardization committee composed of major European telecom operators and manufacturers. It was developed on the basis of the cellular sy...
JasonYoo RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2453  1718  1067  2281  2297  50  35  22  46  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号