EEWORLDEEWORLDEEWORLD

Part Number

Search

55639A-13UL-CSAU1041/4

Description
Toggle Switch, SPDT, Latched, Solder Terminal, Lever Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size163KB,3 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

55639A-13UL-CSAU1041/4 Overview

Toggle Switch, SPDT, Latched, Solder Terminal, Lever Actuator, Panel Mount

55639A-13UL-CSAU1041/4 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerAPEM
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeLEVER
body width7 mm
body height13 mm
Body length or diameter13.2 mm
Contact (AC) maximum rated R load6A@125VAC
Maximum contact current (AC)6 A
Maximum contact voltage (AC)125 V
Manufacturer's serial number55000
Installation featuresPANEL MOUNT
sealEPOXY TERMINAL SEALED
surface mountNO
Switch actionLATCHED
switch functionSPDT
Switch typeTOGGLE SWITCH
Termination typeSOLDER
Base Number Matches1
55000 series
VDE approved toggle switches
• The switches described below are marked VDE as standard.
EN 61058-1
• UL and CSA agency approvals are also available. To order a switch marked
UL or CSA, please complete “Other agency approvals" box.
A
ELECTRICAL SPECIFICATIONS
MATERIALS
• Class I (normal insulation)
• Small contact opening : µ (< 3 mm (.118))
• Current/voltage rating with resistive load : 3A 250VAC - 6A 125VAC
• Dielectric strength :
2.000 Vrms 50 Hz min. between poles and between terminals and frame
1.000 Vrms 50 Hz min. between terminals
• Special body for increased creepage distance and air gap : 3 mm (.118)
GENERAL SPECIFICATIONS
• Contacts : silver
• Case : diallylphthalate (DAP)
• Actuator : brass, chrome plated
with insulating vinyl cap
• Bushing : brass, nickel plated
• Housing : stainless steel
• Terminal seal : epoxy
Further specifications, see 5000 series.
• Insulating cap, compulsory, supplied glued on the lever :
U270 for models 55600A, 55200A and 55200ZA
U1040 for models 55200WA and 55200WA X433
• Ground connector :
U721 compulsory if the panel is not metallic or not connected to ground
• Epoxy sealed terminals standard
MODEL
STRUCTURE
Solder lugs
III
2-3
5-6
Single pole Double pole
55636A
55639A
55646A
55649A
ON
ON
-
OFF
ON
ON
II
I
1-2
4-5
Keyway
Ø6.35-40UNS
(1/4-40UNS)
III
II
24˚
I
Ø4.00
(.157 DIA)
11.50
(.452)
8.00
(.314)
1.00
(.039)
12.00
(.472)
11.00
(.433)
7.00
(.275)
4.70
(.185)
13.20
(.519)
3.70
(.145)
1.80
(.070)
2.00
(.078)
1
2
3
12.00
(.472)
4.75
(.187)
EPOXY
Also available with Ø 6 mm (.236) bushing :
55500.
Straight PC terminals
III
2-3
5-6
Single pole Double pole
55236A
55239A
55246A
55249A
ON
ON
-
OFF
ON
ON
II
I
1-2
4-5
Keyway
4.70
(.185)
Ø1.60
(.062 DIA)
Ø6.35-40UNS
(1/4-40UNS)
III
II
24˚
I
Ø4.00
(.157 DIA)
11.50
(.452)
13.30
(.523)
8.00
(.314)
1.00
(.039)
4.00
(.157)
3.30
(.129)
14.00
(.551)
11.00
(.433)
2.00
(.078)
1
2
3
4.70
(.185)
4.75
(.187)
12.00
(.472)
1.10
(.043)
7.00
(.275)
EPOXY
13.20
(.519)
Also available with Ø 6 mm (.236") bushing :
55100.
A-52
www.apem.com
APEM
4.70
(.185)
4.75
(.187)
Ask a question about UCOS conditional compilation
#ifdef OS_GLOBALS #define OS_EXT #else #define OS_EXT extern #endif The question may be a bit naive, I don't know if this is possible. In a project, many C files call this program, some C files define...
zmsxhy Embedded System
The easiest way to achieve the LED breathing light gradually brightening and fading effect, without the need for single-chip control
Note: Dual color temperature dimming is mainly achieved by changing the capacitance of C1 and C2, which results in different delays in VDD power-on time. Multiple capacitors are increased in sequence ...
chengxl LED Zone
Why is the IRQ pin of PN532 useless?
Shouldn't the PN532's IRQ pin generate an interrupt when a card is received? I'm using the serial port mode, but why is it that even though I set the IRQ pin to be enabled, it doesn't work? I can read...
sky999 RF/Wirelessly
DC working state of amplifier circuit
This section is the key content of this chapter. In this section, we need to master the formula method and the graphical method to calculate the Q point.Before learning, let's first understand a conce...
rain Analog electronics
Garbled characters appear when converting serial port to USB
I don't know if you have ever encountered garbled characters in UBOOT when converting serial port to USB? I use the sbc2410 board, which works fine on Vivi, but garbled characters appear when starting...
pcbrf Embedded System
Looking for a job
I have been in the industry for more than four years and can use Verilog and C language proficiently; I have two years of experience in FPGA and ARM development; I am familiar with common EDA tools; M...
电子老人家 Recruitment

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2394  505  1935  1281  2058  49  11  39  26  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号