EEWORLDEEWORLDEEWORLD

Part Number

Search

5145.A34BFC00C0.811

Description
Mains Power Connector, 15A, 125VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The power connector   
File Size1MB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

5145.A34BFC00C0.811 Overview

Mains Power Connector, 15A, 125VAC, Male, Solder Terminal, ROHS COMPLIANT

5145.A34BFC00C0.811 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARDS: IEC/EN 60320-1; IEC/EN 60950; UL 94V-0; CSA; VDE; QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings15A, 125VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power entry modules with line filter
www.schurter.com/pg06
Inlet filter, front side mounting, circuit breaker TA45 2-pole
545
Standard- or Medical-Filter
Screw-On Version
C14
70° C
Description
- Panel Mount:
Screw-on from front side
- 3 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-
pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter 6145
- We recommend for new applications the new type DF12
Characteristics
- All single elements are already wired
Unwired versions available on request
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage release or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Weblinks
Approvals
Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check,
Distributor-Stock-Check
- VDE License Number: 117118
- UL License Number: E72928
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21acc. to, IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole non-illuminated or
illuminated acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
Circuit breaker
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
EMC products

[Questions and Answers on Purchasing Devices, Lucky Gain] Part 2 - When doing research and development, you need a small number of devices. Would you choose to apply for samples?
Previous issue [E-questions and answers on device purchase, lucky grab] - What would you do if you encounter a fake device? https://bbs.eeworld.com.cn/thread-200638-1-1.html Compressed file password: ...
EEWORLD社区 Buy&Sell
15. Beaglebone peripheral circuit design week 4: wireless data collection and display effects
The event is about to end! ! I feel like many things have not been realized yet! 1. I plan to add a Zigbee module to realize wireless communication! , but time is running out! So I chose the nRF24l01 ...
anananjjj DSP and ARM Processors
How to use the breakpoint function of PB5.0
As the title says, I have not used it much. This time I am using an X86 platform simulator. On this basis, I want to use breakpoints to track the program. Can an expert tell me how to use this functio...
elec2000 Embedded System
Homemade high brightness LED flashlight circuit
As shown in the following figure, capacitor C4 is a 473 monolithic capacitor!! D3 refers to two 1N5819 in parallel!!! High-power LED simple driver, which is used on the high-power white light, but it ...
qwqwqw2088 DIY/Open Source Hardware
What is the process of making a USB management software?
What is the process of making a USB management software?...
qwer1111 Embedded System
Signal Chain Basics - Op Amp
Signal Chain Basics - Op Amp...
linda_xia Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 374  149  2164  492  2730  8  3  44  10  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号