BLP30 AC-DC Series Data Sheet
30 Watts
Features
•
•
•
•
•
•
•
•
•
•
•
•
RoHS compliant for all six substances
2” x 4” footprint
Component height less than 1”
25 W rating with natural convection cooling
30 W rating with 10 CFM airflow
Compliance to EMI Class B
Universal AC input
Short-circuit protection
Overvoltage protection
CE marked to Low Voltage Directive (Pending)
Compliance to EN61000-4-2/-3/-4/-5/-6/-8/-11
Two-year warranty
Applications
•
•
•
•
•
•
•
Datacom (hubs, routers)
POS terminals
Industrial
Cable modems
External disk storage
Medical instrumentation
Computers
Description
The BLP30 Series’ economical and compact construction provides single or three-output AC to DC power
conversion to meet the requirements of most commercial and industrial applications.
Single-Output Model Selection
Model
Nominal
Output Voltage
(VDC)
5V
12V
24V
Min-Max Output
Current (Amps),
Convection
0–5
0 – 2.1
0 – 1.0
Min-Max Output
Current (Amps),
1
Forced Air
0–6
0 – 2.5
0 – 1.25
Peak Output
Current
(Amps)
2
7.2
3.0
1.5
Total
Regulation
3
(%)
±
2
±
2
±
2
Ripple &
Noise
4
pk-pk %
1
1
0.6
BLP30-1005G
BLP30-1012G
BLP30-1024G
Triple-Output Model Selection
Model
Nominal
Output Voltage
(VDC)
+5V
BLP30-3000G
+12V
-12V
1
Min-Max Output
Current (Amps),
Convection
0.2 – 2.5
0.1 – 1.2
0.0 – 0.3
Min-Max Output
Current (Amps),
Forced Air
1
0.2 – 3.5
0.1 – 2.0
0.0 – 0.5
Peak Output
Current
(Amps)
2
5
3
1
Total
Regulation
(%)
3
±2
±5
±5
Ripple &
Noise
4
pk-pk %
1%
1%
1%
2
3
4
10 CFM or 260 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm) cross-sectional area with
power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC input to the DC output.
Peak current duration for less than 30 seconds with a max duty cycle of 10%.
At 25
°C
ambient including voltage set point tolerance, line, and load regulation
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, measured with a twisted pair differentially
across a 10 µF E-cap and a 0.1 µF ceramic cap in parallel. The point of measurement is within 1 cm of the output connection.
JUL 05, 2006 revised to DEC 05, 2006
Page 1 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
ELECTRICAL SPECIFICATIONS
Input Specifications
Parameter
Input Voltage - AC
Input Voltage - DC
Input Frequency
Input Current
Inrush Surge Current
Input fuse
Efficiency
Switching Frequency
AC Input
At 90 VAC input., 30W
Internally limited. 115 VAC, Max Power, 25 °C
Internally limited. 230 VAC, Max Power, 25 °C
Non-user serviceable internally located AC
input line fuse is provided.
At maximum output power.
70
60
75
69
%
kHz
Conditions/Description
Single-phase continuous input range
Min.
90
127
47
Nom.
100 - 250
160/325
50 - 60
0.75
16
32
Max.
264
375
63
Units
VAC
VDC
Hz
A rms
A pk
A pk
Output Specifications
Parameter
Output power
Load transient
Turn on Delay
Rise Time
Hold-up Time
Overvoltage Protection
Conditions/Description
With convection cooling. See Model Selection.
With forced-air cooling. See Model Selection.
Vo1, Vo2, or Vo3 deviation due to a 50 to 100%
load change at a rate of 1A/µs.
Time required for outputs to be within regulation
after initial application of AC input.
Time required for output voltage to rise from
10% to 90%.
At 30W, 115 VAC, 60 Hz.
Main output.
5V:
12V:
24V:
20
5.6
14.0
29.0
6.9
16.7
34.2
Min.
Nom.
Max.
25
30
±5
1.5
20
Units
Watts
%
Sec
ms
Ms
V
Short-circuit Protection
Overshoot
Overshoot
Fully-protected against output short circuit.
Single-output models.
Triple-output models.
2
5
%
%
JUL 05, 2006 revised to DEC 05, 2006
Page 2 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Regulatory & Safety Approvals
Parameter
UL60950-1
CSA-C22.2,
No. 60950-1-03
EN 60950-1
/IEC 60950-1
CE Mark for LVD
CB Approval
Ground Continuity
Dielectric Withstand
Voltage
Conditions/Description
All models are approved.
All models are approved.
All models are approved.
All models are approved.
Completed.
At 12 VDC.
Input-to-Ground (Basic)
.
Input-to-Output (Reinforced). The primary to
secondary test is not performed on completed
assemblies.
Output-to-Ground (Functional).
FCC Part 15.
CISPR 22 and CISPR 11.
Per EN 61000-4-2, level 2.
Per EN 61000-4-3, level 3.
Per EN 61000-4-4, level 3.
Per EN 61000-4-5, class 3.
Per EN 61000-4-6, level 3.
Per EN 61000-4-8.
Per EN 61000-4-11
Per EN 60950
At 115 VAC:
At 230 VAC:
0.2
0.4
mA
Line-to-Line:
Line-to-Ground:
1
1
2
3
1
3
V/m
kV
kV
V/m
A/m
Conducted:
Conducted:
2121
4242
30
A
VDC
VDC
Min.
Nom.
Max.
Units
500
B
B
VDC
Class
Electromagnetic
Interference
ESD
Radiated Susceptibility
EFT/Burst
Input Transient
Protection
RF Immunity
Magnetic Fields
Voltage Interruptions
Leakage Current
JUL 05, 2006 revised to DEC 05, 2006
Page 3 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Environmental Specifications
Parameter
Altitude
Operating Temp
Conditions/Description
Operating.
Non-Operating.
0 ºC to 70 ºC with linear derating to 50% above
50 ºC. Unit will start-up at -20 ºC, but will not
meet all published specifications.
0
50
Min.
Nom.
Max.
10K
50K
70
Units
ASL ft
ASL ft
ºC
Storage Temp
Temperature
Coefficient
Relative Humidity
Shock
0 ºC to 70 ºC (after 15-minute warm-up).
95% relative humidity @ 40 ºC, non-condensing
Operating: half-sine, 11
±3
ms, 3-axis.
Non-Operating: half-sine, 11
±3
ms, 3-axis.
Vibration
Operating: Random vibration; 5 to 500 Hz
(10 minutes, each axis).
Non-Operating: Random vibration; 5 to 500 Hz
(10 minutes, each axis).
-40
±0.02
85
ºC
%/ ºC
95
15
40
2.4
%RH
G
G
Grms
6
Grms
JUL 05, 2006 revised to DEC 05, 2006
Page 4 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Mechanical Drawing – Single Output Models
All dimensions are in inches.
CN1 - AC CONN.
Pin 1
Pin 3
Pin 5
Ø 0.16 (4 places)
AC Neutral
AC Line
AC Ground
4.00 +/- 02
3.750
CN2 - DC CON
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
VOUT
DC COM
VOUT
DC COM
VOUT
TOP VIEW
CN1 input
connector
Pin #1
CN2 - DC output
connector
(see pin-out
table)
2.07
+/-.02
1.750
Pin #1
PCB AC Ground Connection
Point - Solder side
fastener
clearance area
0.25 DIA (4
places)
0.06
1.07
+/-.02
SIDE VIEW
0.91
END VIEW
Printed Circuit Board
0.1
RECOMMENDED MATING CONNECTORS
HOUSING
CN1 and CN2
MOLEX 22-01-2051
MOLEX 22-01-2057
MOLEX 22-01-3057
LEOCO 2530S05000
*
PIN
*
MOLEX 08-52-0123
MOLEX 08-52-0101
LEOCO 2533TPB0000
Equivalent housings and pins can also be used.
JUL 05, 2006 revised to DEC 05, 2006
Page 5 of 6
www.power-one.com