M Series Data Sheet
50-Watt AC-DC Cassette Converters
Features
• RoHS lead-solder-exempt compliant
1
• Rugged electrical and mechanical design
• Outputs individually controlled with excellent dynamic
properties
• Operating ambient temperature range of –40 to 71 °C
with convection cooling
1 The solder exemption refers to all the restricted materials except lead in solder.
Description
The M Series of AC-DC cassettes represents a broad and flexible range of power supplies for use in advanced industrial electronic
systems. Features include high efficiency, reliability, low output voltage noise, and excellent dynamic response to load/line changes
due to individual regulation of each output.
Model Selection
Output 1
Vo
nom
[VDC]
5.1
12
15
24
48
12
15
5.1
5.1
Output 2
Vo
nom
[VDC]
-
-
-
-
-
12
15
12
15
Output 3
Vo
nom
[VDC]
-
-
-
-
-
-
-
12
15
Io
nom
[A]
8
4
3.4
2
1
2
1.7
5
5
Io
nom
[A]
-
-
-
-
-
2
1.7
0.7
0.6
Io
nom
[A]
-
-
-
-
-
-
-
0.7
0.6
Nom. Input
Voltage
Vi [VAC]
100 - 240
100 - 240
100 - 240
100 - 240
100 - 240
100 - 240
100 - 240
100 - 240
100 - 240
Model
Options
LM1001-7R
LM1301-7R
LM1501-7R
LM1601-7R
LM1901-7R
LM2320-7
LM2540-7
LM3020-7
LM3040-7
-9, E, P, D, V, A, F
-9, E, P, D, A, F
-9, E, P, D, A, F
-9, E, P, D, A, F
-9, E, P, D, A, F
-9, E, P, D, A, F
-9, E, P, D, A, F
-9, E, P, D, V, A, F
-9, E, P, D, V, A, F
JUN 20, 2006 revised to JUL 21, 2006
Page 1 of 4
www.power-one.com
M Series Data Sheet
50-Watt AC-DC Cassette Converters
Input
Nom. voltage and frequency
Operating voltage and frequency
Inrush current limitation
Output
Efficiency
Output voltage setting accuracy
Output voltage switching noise
Line regulation
Load regulation
Minimum load
Current limitation main output
Current limitation aux. output(s)
Operation in parallel
Hold-up time
Protection
Input fuse
Input undervoltage lockout
Input overvoltage lockout
Input transient protection
Output
Output overvoltage
Overtemperature protection
Control
Output voltage adjustment
Inhibit
Status indication
Safety
Approvals
Protection degree
Electric strength test voltage
continuous range
continuous range
by thermistor
100 - 240 VAC, 50 - 60, 440 Hz
85 - 264 VAC, 47 - 440 Hz
Io nom
Io nom
IEC/EN 61204, total
Vi min - Vi max, Io nom, each output regulated
Vi nom, 0 - Io nom, each output regulated
not required
rectangular V/I characteristic
rectangular V/I characteristic
by current limitation, only main outputs
Vi = 230 V AC, Io nom
Vi nom,
Vi nom,
up to 81%
better than ±1% Vo nom
typ. 50 mVpp
typ. ±0.2% Vo nom
typ. 0.15% Vo nom
0A
typ. 110% Io nom
typ. 120% Io nom
typ. 90 ms
built-in
T 2.5 A, 250 V AC
typ. 80% Vi min
typ. 110% Vi max
varistor or suppressor diode
no-load, overload, and short-circuit proof
suppressor diode in each output
switch-off with auto restart
typ. 150% Vo nom
TC typ. 100 °C
single output types
TTL input, output(s) disabled if open circuit
3 LEDs: OK, inhibit, overload
0 - 110% Vo1 nom
EN 60950, UL 1950, CSAC22.2 No. 950
units without options
Input against (case + outputs)
Class I equipment
IP 40
2 kV AC
JUN 20, 2006 revised to JUL 21, 2006
Page 2 of 4
www.power-one.com
M Series Data Sheet
50-Watt AC-DC Cassette Converters
EMC
Electrostatic discharge
Electromagnetic field
Electr. fast transients/bursts
Surge
Conducted disturbances
Electromagnetic emissions
Environmental
Operating ambient temperature
Operating case temperature TC
Storage temperature
Damp heat
Vibration, sinusoidal
Shock
Bump
Random vibration
MTBF
IEC/EN 61000-4-2, level 4 (8/15 kV)
IEC/EN 61000-4-3, level x (20 V/m)
IEC/EN 61000-4-4, input, level 3/4 (2/4 kV)
IEC/EN 61000-4-5, input, level 3/4 (2/4 kV)
IEC/EN 61000-4-6, level 3 (10 V)
CISPR 22/EN 55022, class I, conducted
criterion A
criterion A/B
criterion A/B
criterion A
criterion B
class B
Vi nom, Io nom, convection cooled
Vi nom, Io nom
non operational
IEC/EN 60068-2-78, 93%, 40 °C
IEC/EN 60068-2-6, 10 - 60/60 - 2000 Hz
IEC/EN 60068-2-27, 6 ms
IEC/EN 60068-2-29, 6 ms
IEC/EN 60068-2-64, 20 to 500 Hz
MIL-HDBK-217E, GB, 40 °C, single output models
–25 to 71 °C
–25 to 95 °C
–40 to 100 °C
56 days
0.35 mm/5 gn
100 gn
40 gn
4.9 gn rms
320 000 h
Options
Extended temperature range
–40 to 71 °C, ambient, operating
Electronic inrush current limitation
Output voltage adjustment
95 - 105% Vo nom, excludes feature R
Input and/or output undervoltage monitoring, excludes option V
Input and/or output undervoltage monitoring (VME), excludes option D
Test sockets for check of output voltage
Fuse not user-accessible
-9
E
P
D0 - D9
V1 - V3
A
F
Pin Allocation
Pin
2
5
8
11
14
17
14
17
20
23
26
29
32
Electrical determination
Inhibit control input
Data safe or ACFAIL
Output positive
Output negative
Control input +
Control input –
Output positive
Output negative
Output positive
Output negative
Protective earth PE
AC input neutral
AC input phase
LM1000
i
D or V
Vo+
Vo–
R
G
LM2000
i
D or V
LM3000
i
D or V
Vo3+
Vo3–
Vo+
Vo–
N
L
Vo2+
Vo2–
Vo1+
Vo1–
N
L
Vo2+
Vo2–
Vo1+
Vo1–
N
L
JUN 20, 2006 revised to JUL 21, 2006
Page 3 of 4
www.power-one.com
M Series Data Sheet
50-Watt AC-DC Cassette Converters
Mechanical Data
Dimensions in mm. The power supplies are designed to be inserted into a 19” rack, 160 mm long, according to IEC 60297-3.
26
23
11
14
17
20
29
32
2
5
8
09012
6TE
28.6
12.1
Mounting holes for retaining clips (HZZ01209)
3.27
15
20.5
Male connector H11 according to DIN 41 612
(Gold plated contacts on customer's request)
European
Projection
2TE
100
34
1.6
Front plate
103
20
M 3; depth = 4 mm
(chassis mount)
Main
face
Rear
face
168.5
159.4
173.7
127
22
Measuring point for
case temperatureT
C
68
Mounting plane of
connector H11
(11.6)
88
111.2 (3U)
94.5
95
30.48
25.40
20.32
15.24
10.16
5.08
0
4
38.7
Back plate
ø 3.5
22.30
17.25
12.17
7.09
0
OK (LED
green)
Inhibit i (LED red)
Potentiometer (option D or V)
I
oL
(LED red)
Test sockets (option A)
Potentiometer(s) (option P)
Accessories
Front panels 19” (Schroff/Intermas)
Mating H11 connectors with screw, solder, fast-on or press-fit terminals
Connector retention facilities and code key system for connector coding
Flexible PCB for connecting the converter via an H11 connector, if mounted on a PCB
Chassis or wall mounting plates for frontal access
Universal mounting brackets for chassis or DIN-rail mounting
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
JUN 20, 2006 revised to JUL 21, 2006
Page 4 of 4
31.5
ø 4.0
www.power-one.com