MPB125 Multiple-Output AC-DC Series Data Sheet
Features
RoHS lead free and lead-solder-exempt products are available
High power density in an industry-standard 3" x 5" footprint
Power Factor Correction (PFC) meets EN61000-3-2
Main output remote sense
Power Good signals
CE marked to Low Voltage Directive
Input transient & ESD compliance to
EN61000-4-2/-3/-4/-5
• MTBF In excess of 1M hours based upon field data
• Optional remote on/off with 5V standby
•
•
•
•
•
•
•
Description
(See page 4 for ordering information)
The MPB125 Series incorporates patented high efficiency circuitry, high power density and active Power Factor Correction (PFC)
to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations.
Dual output units deliver a regulated main output plus a second 12V output for fans or other system functions. Multiple output models
provide tightly regulated DC power in a variety of configurations. The MPB125 is rated for convection as well as forced-air cooling.
Full output power is available with as few as 5 Cubic Feet per Minute (CFM) forced-air cooling with the exception of the MPB125-
2003 and -2003D which need only 10 CFM for full power. Optional remote on/off with standby power is also provided (see Options).
The MPB125 product line is approved to the latest international regulatory standards, and displays the CE Mark.
Multiple Output Model Selection
MODEL
OUTPUT
VOLTAGE
(VOLTS)
MAXIMUM OUTPUT
CURRENT (AMPS),
130 LFM
TOTAL
REGULATION
%
RIPPLE & NOISE
1
% pk-pk
REGULATION RANGE
MPB125-2003
2
MPB125-2005
3, 4
MPB125-2012
3, 4, 5
MPB125-2015
3, 4, 5
MPB125-2024
3, 4, 5
MPB125-2048
3, 4, 5
6
MPB125-3000
MPB125-4250
6
MPB125-4350
6
+3.3V
+12V
+5V
+12V
+12V
12V
+15V
12V
+24V
12V
+48V
12V
+5V
+12V
-12V
+2.5V
+5V
+12V
-12V
+3.3V
+5V
+12V
-12V
30A
0.5A
25A
0.5A
10.5A
0.5A
8.3A
0.5A
5.2A
0.5A
2.6A
0.5A
16.5A
5A/9Apk
0.5A
12A
7
15A
7
5A/9Apk
0.5A
10A
7
15A
7
5A/9Apk
0.5A
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±4%
±5%
±5%
±3%
±4%
±5%
±5%
±3%
±4%
±5%
±5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
8
1%
1%
2%
1%
8
1%
1%
1.5%
1%
8
1%
1%
3.20V to 3.40V
11.80V to 12.60V
4.85V to 5.15V
10.80V to 12.60V
11.64V to 12.36V
11.40V to 12.60V
14.54V to 15.45V
11.40V to 12.60V
23.28V to 24.72V
11.40V to 12.60V
46.56V to 49.44V
11.40V to 12.60V
4.85V to 5.25V
11.40V to 12.60V
-11.40V to -12.60V
2.42V to 2.58V
4.85V to 5.25V
11.40V to 12.60V
-11.40V to -12.60V
3.20V to 3.40V
4.85V to 5.25V
11.40V to 12.60V
-11.40V to -12.60V
NOTES:
1
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2
For MPB125-2003 and -2003D, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1.
V1 current can be as high as 25A with a minimum airflow of 5 CFM.
3
Maximum forced-air output power is 125 watts with 5 CFM airflow.
4
Maximum convection output power is 70 watts.
5
V2 is isolated from V1 and can be used as a negative or positive output.
6
12V output’s peak load maximum duration is 30 seconds. Average current must not exceed 5A.
7
Maximum power of 80 watts from V1 + V2 with 5 CFM forced-air cooling. See Application Note #M3 for details.
8
For loads less than 10 watts on V1 + V2 + V3, ripple and noise on the +5V output is Max. 2% peak-to-peak.
OCT 24, 2005 revised to JUN 05, 2006
Page 1 of 9
www.power-one.com
MPB125 Multiple-Output AC-DC Series Data Sheet
Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage- AC
Input Frequency
Brownout Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor Circuitry
Operating Frequency
Continuous input range.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Over full AC input voltage range at full rated load.
90 VAC at full rated load.
Non-user serviceable internally located AC input line fuse, 250 VAC, 3.15A.
Internally limited by thermistor,
110VAC:
one cycle, 25° C.
220VAC:
Active PFC meets requirements of EN61000-3-2.
Switching frequency of main transformer.
90
47
90
17
264
63
1.8
23
46
45
VAC
Hz
VAC
ms
A
RMS
A
PK
kHz
Output Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Minimum Loads
Ripple and Noise
Output Power (Note 1)
Overshoot /Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
Full Load, 230VAC. Varies with distribution of loads among outputs.
(Minimum efficiency reflects that of MPB125-2003D and -2005D models.)
V1 + V2 + V3 for MPB125-4XXX and -3000.
V1 for MPB125-2XXX for full regulation on V2. All models operate
at no load without any damage and meet all specs on V1 above 0 amps.
Full load, 20 MHz bandwidth.
At 5 CFM forced-air cooling. See Application Note #M3 for details.
Convection: Consult Factory
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes from 85-132 VAC
or 170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Maximum deviation due to a 25% load change with unit at 75% load.
All models except MPB125-2005 and -2005D.
Model MPB125-2005 and -2005D.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90% except for MPB125-2005
and -2005D.
MPB125-2005 and MPB125-2005D.
73
5
5
80
85
%
Watts
See Model Selection Chart
125
10
See Model Selection Chart
3
5
0.2
0.2
1
1.5
20
100
Watts
%
%
Sec
ms
ms
Interface Signals and Internal Protection
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
V1 of dual and triple output models; V1 & V2 outputs of 4-output models.
MPB125-2003 and -2003D
3.67
4.80
MPB125-4250 (V1)
3.20
4.00
MPB125-4350 (V1)
3.76
4.80
5V Output of MPB125-2005 and -2005D, MPB125-3000, or MPB125-4X50
5.74
7.00
VDC
MPB125-2012
13.5
16.5
MPB125-2015
17.0
19.0
MPB125-2024
26.9
31.1
MPB125-2048
57.6
62.4
Overload Protection
Fully protected against output short circuit or overload. Automatic recovery upon
removal of overload condition. MPB125-2003, -2003D -2005, and -2005D latch OFF if
overload occurs on V1 which requires an AC reset.
Remote Sense (Note 2)
Total (+sense and -sense) voltage compensation for cable losses on
Dual Output Models
dual output models.
500
mV
Remote Sense (Note 2)
On models MPB125-4250 and -4350 remote sense is provided on
Triple & Quad Output Models
the 2.5 and 3.3V outputs, respectively.
MPB125-3000 does not have positive remote sense.
Total voltage compensation for cable losses on +Sense.
200
mV
Total voltage compensation for cable losses on -Sense.
100
NOTES:
1) For MPB125-2003, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1. V1 current can be as high as 25A with a
minimum airflow of 5 CFM.
2) -Sense must be connected to output common or load common for proper power supply operation.
OCT 24, 2005 revised to JUN 05, 2006
Page 2 of 9
www.power-one.com
MPB125 Multiple-Output AC-DC Series Data Sheet
Interface Signals and Internal Protection (Cont.)
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Power Good Signal
AC/DC indicator - This signal indicates the status of the AC input or DC outputs.
When there is sufficient AC voltage and the outputs are operating normally, an
open collector signal is provided.
Turn-On delay time from application of AC:
50
Warning time before outputs go out of regulation:
5
Warning time before outputs deviate ±10% from the nominal value:
15
Sync Current
Pull-up Voltage
Provided on dual-output models. Open collector signal intended to drive an LED.
Closed collector occurs when the Power Good Signal is in its open collector state.
Sync Current
Pull-up Voltage
Protected against overtemperature conditions.
Unit recovers when overtemperature condition is removed.
Provided on dual-output models. Up to 4 units can be connected in parallel.
There are some limits for parallel operation. See MPB125 Applications Note.
N+1 redundancy is provided. V2 needs an external isolation diode for N+1 operation.
An external diode is required on MPB125-2003 and MPB125-2005 models for
redundancy on both V1 and V2, or when ordering, you can specify MPB125-2003D or
-2005D which have an internal isolation diode.
Internal isolation diode is provided on V1 for all dual-output models except the
MPB125-2003 and MPB125-2005. Specify MPB125-2003D or MPB125-2005D,
respectively, if an internal isolation diode is required for these models.
500
ms
20
30
mA
V
Power Supply OK Signal
20
30
mA
V
Thermal Shutdown
Current Share
Isolation Diode
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference
ESD Susceptibility
Flicker
Radiated Susceptibility
EFT/Burst
Input Transient Protection
RF Immunity
Magnetic Fields
Voltage Dips
Insulation Resistance
Leakage Current
UL60950-1.
CSA 22.2 No. 60950-1.
EN60950 (TÜV).
IEC60950-1.
AC to chassis.
1500
Input to output.
3000
EN55022 Conducted.
B
Per EN61000-4-2, Level 4
8
Per EN61000-3-3.
Per EN61000-4-3.
Per EN61000-4-4.
1
Per EN61000-4-5, Level 3, 2 kV (Line-to-Gnd) minimum, 1 kV (Line-to-Line) minimum.
Per EN61000-4-6. 0.15 to 80 MHz (1 kHz sinewave)
Per EN61000-4-8.
Per EN61000-4-11.
Input to output.
Per EN60950 (264 VAC)
VAC
VDC
Class
kV
3
V/m
kV
V/m
A/m
M
mA
3
1
10
1.0
OCT 24, 2005 revised to JUN 05, 2006
Page 3 of 9
www.power-one.com
MPB125 Multiple-Output AC-DC Series Data Sheet
Environmental Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating Temperature
Storage Temperature
Forced-Air Cooling
1
Operating
Non-Operating
Derate linearly from 50 to 70°C to 50% power at 70°C.
At 100% load:
MPB125 models will operate at -20°C, but will not meet all specifications.
Forced-air cooling of 5 CFM is required for full output power except for
MPB125-2003 and -2003D. Air velocity is measured with power supply mounted on
0.375" (9.5mm) standoffs. Airflow direction is from the input section to
the output section. See Application Note #M3 for details.
Included in total regulation of outputs.
Non-Condensing.
Operating: 11 ±3ms, 3 axes, Half Sine.
Non-operating: 11 ±3ms, 3 axes, Half Sine.
Operating:
Random vibration, 5-500 Hz, 10 minutes each axis.
Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis.
0
-40
10K
50K
50
85
ASL Feet
°C
°C
Temperature Coefficient
Relative Humidity
Shock
Vibration
5
95
15
40
2.4
6.0
%RH
Gpk
G
RMS
G
RMS
Options
DESCRIPTION
NOTES
Remote On/Off
Standby Output
(Option R)
Remote On/Off is a TTL-comatible signal. A logic “high” or open circuit turns the unit on. Reverse inhibit logic can be achieved
by changing the position of the J6 connector. A logic “low” inhibits all outputs except the 5V standby. At remote off, the Power
Good signal will warn the host equipment 2 milliseconds before the main output goes out of regulation. The rating of the
standby output is +5V @ 0.2 Amps. Total regulation is ±5 %. Maximum noise and ripple is 50 mV peak-to-peak @ a 20 MHz
bandwidth.
NOTE: The addition of Option “R” increases the supply width from 3.0 to 3.8 inches. Consult factory for availability.
NOTES:
1
For MPB125-2003 and -2003D, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1. V1 current can be as high as
25A with a minimum airflow of 5 CFM.
Ordering Information:
OPTIONS
SUFFIXES TO ADD TO PART NUMBER
RoHS lead solder exempt 1
RoHS compliant for all 6 substances
1 The solder exemption refers to all the restricted materials except lead in solder.
No RoHS suffix character required.
Add “G” as the last character of the part number.
OCT 24, 2005 revised to JUN 05, 2006
Page 4 of 9
www.power-one.com
MPB125 Multiple-Output AC-DC Series Data Sheet
Mechanical Drawing (-2012, -2015, -2024, & -2048 Models)
WEIGHT:
J 1 - A C INPUT CONNECTOR
Pin 1
Pin 2
Pin 3
NEUTRAL
N O PIN
LINE
5.00"
(127.0)
4.55"
(115.57)
Ø 0.16" (4 PL)
(4.06)
0.63 lb. (0.3 kg)
J2 -
Pin
Pin
Pin
Pin
Pin
Pin
J3 -
Pin
Pin
Pin
Pin
Pin
Pin
J4 -
Pin 1
Pin 2
1
2
3
4
5
6
1
2
3
4
5
6
J 2 - V 1 DC OUTPUT
CONNECTOR
TOP VIEW
PIN #1
MPB125
-2012
+12V
+12V
+12V
RTN
RTN
RTN
-2015
+15V
+15V
+15V
RTN
RTN
RTN
-2024
+24V
+24V
+24V
RTN
RTN
RTN
-2048
+48V
+48V
+48V
RTN
RTN
RTN
3.00" 2.78"
(76.2) (70.6)
2.56"
(65.02)
PIN #1
PIN #1
J3- SIGNAL
CONNECTOR
PIN #1
J4- V2 DC OUTPUT
CONNECTOR
FASTENER
CLEARANCE
AREA (4 PL)
RTN
- SENSE
+ SENSE
CURRENT SHARE
POWER GOOD
POWER SUPPLY OK
SAFETY GROUND
CONNECTION POINT
SCREWS SHOWN
FOR REFERENCE
ONLY
0.06"
(1.5)
+12V
+12V RTN
1.25"
(31.75)
1.00"
(25.4)
PRINTED
CIRCUIT
BOARD
SIDE VIEW
0.19"
(4.8)
END VIEW
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB125
-2012
-2015
-2024
-2048
09-50-8031
08-52-0113
09-50-8061
08-52-0113
22-01-3067
08-50-0114
22-01-3027
08-50-0114
J1
J2
J3
J4
Housing
Pins
Housing
Pins
Housing
Pins
Housing
Pins
OCT 24, 2005 revised to JUN 05, 2006
Page 5 of 9
www.power-one.com