EEWORLDEEWORLDEEWORLD

Part Number

Search

64-32329-74-03001

Description
Cable Assembly
CategoryConnector bracket   
File Size566KB,1 Pages
ManufacturerGould Fiber Optics
Download Datasheet Parametric View All

64-32329-74-03001 Overview

Cable Assembly

64-32329-74-03001 Parametric

Parameter NameAttribute value
MakerGould Fiber Optics
Reach Compliance Codeunknown
applicationTELECOM; INSTRUMENTATION; MEDICAL
CertificationUL
ConnectorSide1SC/APC
ConnectorSide2SC/UPC
Connector bracket typeCABLE ASSEMBLY
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
shieldNO
Base Number Matches1
PATCH CORDS
Gould optical cable assemblies feature quality parts and guaranteed performance specifications.
•Length tolerance is ±10% (minimum tolerance is ±5cm)
•Specifications are per mated pair at both 1310nm and 1550nm
Connector Insertion/Return Loss
Specifications for SMF-28 Fiber
End
Number
2
3
4
5
6
7
Connector
Insertion
Loss (dB)
≤ 0.5
≤ 0.25
≤ 0.25
< 0.25
≤ 0.25
≤ 0.25
Typical
Return
Loss (dB)
> 40
> 50
> 50
> 40
> 60
> 60
Features
Low Optical Loss
Low Polarization
Dependent Loss
Applications
Telecom
Instrumentation
Medical
ST
FC
SC
LC
FC/APC
SC/APC
PATCH CORDS
Product #:
6
-
-
Connector
End A
2
3
4
5
6
7
ST/UPC
FC/UPC
SC/UPC
LC/UPC
FC/APC
SC/APC
0
2
3
4
5
6
7
-
Connector
End B
Pigtail
assembly
ST/UPC
FC/UPC
SC/UPC
LC/UPC
FC/APC
SC/APC
Buffer Type
Length in
meters xxxx
0300
0350
3m
3.5m
etc
1
Patchcord Type
2
4
singlemode
multimode
Testing Requirements
0
1
2
3
insertion loss testing data only
insertion loss and return loss testing data
insertion loss and endface geometry data
insertion loss, return loss and endface
geometry data
Fiber Type
03
06
11
12
22
23
25
27
32
54
Corning SMF-28
TM
, 100kpsi proof test on fiber
Corning Flexcore (5/125)
50/125 Graded Index (Corning)
62.5/125 Graded Index (Corning)
200/230/500, 0.37NA SI MM HCS (Lucent)
200/230/500, 0.48NA SI MM HCS (Lucent)
100/140/250 Step Index (Lucent)
Corning Flecore (7/125)
Corning SMF-28
TM
, 200 kspi proof test on fiber
Corning Flecore (7/125), 200 kspi proof test on fiber
10
21
22
23
24
25
26
27
28
29
31
32
33
34
No buffering ( not recommended)
900 micron, white, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, orange, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, blue, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, red, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, green, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, black, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, brown, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, gray/slate, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, yellow, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
2.9mm x 0.4mm, Kevlar reinforced tubing, yellow
2.9mm x 0.4mm, Kevlar reinforced tubing, orange
2.9mm x 0.9mm, Kevlar reinforced tubing, orange
2.9mm x 0.45mm, Kevlar reinforced tubing, black
Specifications are based on non-connectorized products. For connectorized specifications, please call
sales for details. Custom optical & mechanical configurations are available upon request.
46
Call Toll Free: 1-800-544-6853 • FAX: 410-987-1201 • E-mail: info@gouldfo.com
The fir filter waveform is incorrect? Why?
The input and output waveforms of the low-pass FIR filter are as follows. Why does the output become six frequencies? There should still be only the middle two....
骑士番茄 DSP and ARM Processors
SQLCE RDA synchronization SQL2000 strange things (extremely urgent)
I use RDA synchronization method to synchronize SQLCE3.0 and SQL2000. Situation: 1. Local deployment with VS2005 is completely OK, and it can also connect, and there is no problem. 2. However, when I ...
xw99 Embedded System
It is recommended to set up a separate IoT section
It is not reasonable to put ESP8266 in RF/wireless...
ericdai Suggestions & Announcements
Help: MCU ADC acquisition problem
[i=s]This post was last edited by chenzhouyu on 2018-7-4 17:38[/i] I have a previous project on hand. During production, I found that the ADC was too small. I used a multimeter to measure the voltage ...
chenzhouyu Analog electronics
Read and learn about Keysight's oscilloscope and calibration services, answer questions and win prizes!
[b][font=微软雅黑][size=3][url=https://www.eeworld.com.cn/huodong/KEYSIGHT_ZT_20170628/HDDT/index.html]Read and learn about Keysight's oscilloscope and calibration services, answer questions and win prize...
EEWORLD社区 Test/Measurement
Why are all the packages on the generated PCB green?
As shown in the picture. And my AD6 will get stuck when I click on the automatic routing. I don't know what's going on....
zxpla PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2703  2077  2268  1035  464  55  42  46  21  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号