Part Number

Search

800-011-07C12-37GY

Description
Circular Connector, 37 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,
CategoryThe connector   
File Size214KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance  
Download Datasheet Parametric View All

800-011-07C12-37GY Overview

Circular Connector, 37 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,

800-011-07C12-37GY Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceANODIZED BLACK
Shell materialALUMINUM ALLOY
Housing size12
Termination typeCRIMP
Total number of contacts37
Base Number Matches1
A
B
C
In-Line
Rear Panel Jam Nut Mount
Square Flange Mount
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
Series 800
Series 800 “Mighty Mouse”
Original UNF Threaded Coupling
Series 800 Receptacles – Crimp Termination
Integral Band Platform
for direct attachment of a cable
shield using a
BAND-IT®
strap. Install a boot, or overmold
onto the band platform. An accessory thread is available
for attaching strain reliefs and backshells.
Three Shell Options:
Jam nut with o-ring for rear panel
mounting, square flange or in-line receptacle for free-hanging
cables.
HOW TO ORDER
Sample Part Number
80 0- 0 11
Series
-0 1
Shell Style
M
Shell Material /
Finish
C
6-4
Shell Size- Insert
Arrangement
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contacts
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
N
Shell Key
Position
N
Normal
-01
In-Line
800-010
Receptacle with
Banding Platform
-02
Square Flange
for Front or Rear
Mounting
5-3
Aluminum / Black
6-1
Anodize
6-4
M
6-7
Aluminum / Electroless
7-1
Nickel
7-10
NF
8-13
Aluminum / Cadmium
9-4
with Olive Drab
9-19
Chromate
10-26
ZN
12-2
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
12-37
X
Pos. X
P
Pin
Y
Pos. Y
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
Z
Pos. Z
800-011
Receptacle with
Accessory Thread
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
-07
Jam Nut for Rear
Panel Mounting
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
C-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
COM Port
I am using the YLS3C2440 development board recently and I am going to use a GPRS module. This module is a USB to serial port. I connected it to the development board through the USB port and connected...
yynan Embedded System
New: TI's code-free, sensorless FOC 70W BLDC motor drive solution
I am curious. There is no code. Can it adapt to motors with different parameters? I plan to learn more at the TI live on September 26.TI launches the industry's first codeless, sensorless FOC 70W BLDC...
nmg Motor Drive Control(Motor Control)
How can the ST BlueNRG-LP, as a slave, prohibit pairing requests initiated by the Bluetooth host and only allow the slave to initiate pairing requests?
Currently, ST BlueNRG -LP has realized the pairing function as a slave, in which pairing can be initiated by both the host and the slave. How can I prohibit the host from initiating pairing?...
fx427103 ST - Low Power RF
Easy Power Supply Practical Experience
According to my weekly plan, I have to build a circuit to power the microcontroller. Then I designed a 5V circuit diagram last time. I found a few resistors that are closest to the voltage. I soldered...
ddllxxrr Analogue and Mixed Signal
Problem sending strings through the serial port
I would like to ask, when writing a 430 program in C, how to output an int or longer variable to the serial port? There is no relevant code in the example, thank you! !...
jclhp Microcontroller MCU
Will the sleep time and working time under the sleep mechanism affect the sending of large data packets?
Will the sleep time and working time in the sleep mechanism affect the sending of large data packets? How to send large data packets?...
wlg125600 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 111  2233  2346  1486  2354  3  45  48  30  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号