5145.ABD6FC00C0.510

Description
Mains Power Connector, 6A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The power connector   
File Size1MB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

5145.ABD6FC00C0.510 Overview

Mains Power Connector, 6A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT

5145.ABD6FC00C0.510 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARDS: IEC/EN 60320-1; IEC/EN 60950; UL 94V-0; CSA; VDE; QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings6A, 250/125VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power entry modules with line filter
www.schurter.com/pg06
Inlet filter, front side mounting, circuit breaker TA45 2-pole
545
Standard- or Medical-Filter
Screw-On Version
C14
70° C
Description
- Panel Mount:
Screw-on from front side
- 3 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-
pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter 6145
- We recommend for new applications the new type DF12
Characteristics
- All single elements are already wired
Unwired versions available on request
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage release or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Weblinks
Approvals
Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check,
Distributor-Stock-Check
- VDE License Number: 117118
- UL License Number: E72928
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21acc. to, IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole non-illuminated or
illuminated acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
Circuit breaker
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
EMC products

Several common problems with infrared cameras (transferred)
Some small ideas about infrared have been around for a long time. Just as the May Day holiday is coming, I write casually. Some ideas have been around for a long time in the company, some are told by ...
clark Industrial Control Electronics
The McBSP interface of VC5509A can configure
[size=4] The McBSP interface of VC5509A can be configured in 4-wire SPI mode, so it can communicate directly with ADXL345. The DSP motherboard SDUST VC5509A V1.1 made in the laboratory is still used. ...
Jacktang DSP and ARM Processors
Is ADI technology still here?
I remember ADI technology was here before, and it was convenient to apply for samples. Is it still there? I want to do current output...
kangkls ADI Reference Circuit
Modelsim single step debugging
I have found a lot of information on the Internet, but there is not much information about single-step debugging. Can you recommend some information?When debugging in a single step, lines 17-19 are ex...
tianma123 FPGA/CPLD
WINCE is in the process of distributing.
ARM WINCE group welcomes everyone to join: 35526208...
lyang_c Embedded System
LM3S9L97 CAN module
Hey guys! I built a LM3S9L97 board by myself. Now I have some questions about the CAN module. Please help me. TX After initialization, set the ID and data.g_sCANMsgObject1.ulMsgID = 0x1001; //CAN mess...
轻轨002 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 784  2797  1341  814  1114  16  57  27  17  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号