Space saving with scoop proof connector for harsh and EMI applications.
A compact solution
Diameter up to 45% smaller than D38999 size 9.
Integrated backshell: up to 50% shorter.
A high density solution
With #26 contacts (according 39029).
6 layouts (size 3, 5 and 7 with #22 & #26).
Excellent features
Designed for D38999 requirements.
IP67 sealing when mated.
Ballseal (EMI).
RoHS and Cadmium free
Available in zinc nickel (RoHS) plating, as well
as nickel and olive drab cadmium.
Not QPL listed.
8BA Series
|
Break Away
Description
• A compact solution
- The smallest connector available on the
market (shell size 3)
- Break away: quick disconnect
- Integrated backshell:
. Easy to wire and handle
. Compatible with heat shrink boot and
braid retention band
. Compliant with overmolding
• A versatile solution
- 3 shells sizes: 3, 5, 7
- Plug; In line and jam nut receptacle
- Crimp & PC tails contacts (on request)
- Removable contacts #22D & #26
- 6 keyings
• Harsh environment-resistant solution
- Scoop Proof (when sockets mounted into
receptacle only)
- Cavity to cavity sealed with interfacial seal
and grommet
- Fluid resistant
Technical features
Mechanical
• Shell:
Aluminum alloy
• Shell plating:
Aluminum:
. Zinc nickel (RoHS)
. Nickel (RoHS)
. Olive drab cadmium
• Insulator:
Thermoplastic
• Contact body:
Copper alloy
• Contacts plating:
Gold over nickel plated
• Shell endurance:
Aluminum:
500 mating/unmating cycles
• Vibration:
30 grms ambiant, 2 axes during 8 hours
• Shock:
300g, 3 ms
Electrical
• Wire size
Layouts
03-05; 05-06;
07-09
03-35; 05-35;
07-35
Wire (AWG)
24-30
22-28
Environmental
• Temperature range:
-55°C to +175°C
• Water immersion:
IP 67 on mated connector
1 meter for 30 min minimum
> IP68 with appropriate cable termination
• Salt spray:
Zinc nickel: 500 hours
Nickel: 48 hours
Olive drab cadmium: 500 hours
• Test voltage (at sea level):
Size 22D: 1000 Vrms
Size 26: 400 Vrms
• Contact resistance:
Size 22D: <14.6 mΩ
• Contact rating:
Size 22D: 5A
Size 26: <16 mΩ
Resistance to fluids
• According to MIL-DTL-38999 standard
Gasoline: JP5 (OTAN F44)
Mineral hydraulic fluid: MIL-H-5606
(OTAN H515)
Synthetic hydraulic fluid: Skydrol 500 B4
• Compatible with de-icing fluids containing
potassium acetate
Size 26: 3A
• Contact retention:
Size 22D: 45N Size 26: 30N
• Shell to shell continuity (typical value)
Shell
size
3
5
7
Aluminum
version
10 mΩ
• EMI:
Aluminum: -70dB @ 1GHz
2
8BA Series
|
Break Away
Shell types
Plug
For other configuration or PC tail version, please consult us.
In line receptacle
Jam nut receptacle
Contact layouts
03
05
35
05
06
35
07
09
35
Size 3: Marking on shell.
Rear view of receptacle for male and
female insulator.
Opposite marking between plug and
receptacle.
Sizes 5 and 7: Marking on insulator.
Rear view of male insulator for plug
and receptacle.
Opposite marking between male and
female insulator.
5#26
3#22D
6#26
3#22D
9#26
5#22D
Ordering information
Basic Series
Shell type:
1:
In line receptacle
6:
Plug
7:
Jam nut receptacle
Shell size: 03, 05, 07
Plating :
Z:
Black zinc nickel
F:
Nickel
W:
Olive drab cadmium
Contact layouts:
See above
Contact type:
P:
Pin
S:
Socket (Scoop proof only when socket contacts mounted in Type 1 & Type 7)
Orientation: N, A, B, C, D, E
(see page 5)
8BA
1
03
W
05
P
N
3
8BA Series
|
Break Away
Dimensions
Plug - Shell type 6
B
B
Shell
size
D
A
A
D
3
5
C
Shell size 3 & 5
Shell size 7
C
7
A
10.3
12.2
14.3
B Max
18.4
19.4
24
C Max ØD Max
6.1
6.1
6.1
7.3
8.9
10
In line receptacle - Shell type 1
B
Shell size
3
A
D
5
7
C
A
11
12.8
14.3
B Max
17.7
19.1
24
C Max ØD Max
6.1
6.1
6.1
7.3
9
10
Jam nut receptacle - Shell type 7
B
D
B
D
G
A
A
F
F
H
E
C
Thread
Panel
thickness
Thread
E
C
Panel
thickness
Shell size 3
Shell size
3
5
7
Thread
7/16’’28 UNEF 2A
1/2’’28 UNEF 2A
9/16’’24 UNEF 2A
A Max
10.55
12.2
13.6
Shell size 5 & 7
B Max
17.7
22.5
24
C Max
3.2
3.2
3.2
D
1.75
±0.3
1.75
±0.3
1.75
±0.3
E Max ØF Max ØG Max
6.1
6.1
6.1
7.3
8.9
10
17.5
19.5
21
ØH
Panel cut out
J
11.3
±0.1
10.6
±0.05
12.8
±0.1
12.3
±0.05
14.5
±0.1
13.8
±0.05
Note: All dimensions are in millimeters (mm)
J
4
8BA Series
|
Break Away
Orientations
Shell size 3
Master Key
Shell sizes 5 & 7
Master Key
X°
Y°
Shell
size
3
5&7
Angles
X°
Y°
Z°
N
153
145
75
A
51
130
120
B
102
110
120
C
204
155
115
D
255
90
115
E
306
90
180
Z°
Viewed from front face of plug
Connector weights
Aluminum version -
in gram ±10 %
Shell size
& layout
3-05
5-06
7-09
Plug
Without contacts
1.7
2.6
4.3
With crimp contacts
1.8
2.8
4.7
In line receptacle
Without contacts
1.3
2.9
4.7
With crimp contacts
1.4
3.1
5.1
For further information contact us at
contactmilaero@souriau.com
or visit our web site
www.souriau.com
5
All information in this document presents only general particulars and shall not form part of any contract. All rights reserved to SOURIAU for changes without prior notification or public announcement. Any duplication is prohibited, unless approved in writing.
Brother Niu attended Vforum 2010 and listened to the speech of Smart IBM System - Intelligent Hardware Platform for Cloud Computing and the speech of INTEL Open Data Center - New Technology Trends to ...
There are many development directions for embedded systems, with different thresholds. Specifically: 1. Single-chip microcomputer: industrial control program (not running OS) - easy to get started, no...
The dry coupling ultrasonic testing method does not require the application of liquid coupling agents such as water or oil on the surface of the material to be tested. It is easy to operate and flexib...
I want to ask you guys, how are the 30-yuan fiber optic transceivers made? Even if they are assembled by yourself, don't you provide customer service? I heard from customers that some transceivers wil...
The control chip I use is S3C2410, and the network card chip is AX88796. The network card is on BANK2, with a base address of 0x200 and a logical address of 0x10000200. The register width of Ax88796 i...
Where can I download the IRMX operating system? It would be best if it supports Win98 or Win3.1! Thank you. It would be best if it is an installation version....
"Have you set your calendar reminder?"
On August 24, Nvidia Robotics' official account posted a photo of a black gift box on a social media platform, with an attached greeting card sig...[Details]
Is pure electric vehicles a false proposition for long-distance driving? At least from my personal perspective, based on current technological and infrastructure standards, I believe so. Below, I'l...[Details]
Topics: Bring Your Own Device (BYOD) trends; the impact of using employees' own mobile devices to control access to work facilities and equipment on information security; and ways to securely imple...[Details]
In recent years, with the application of the IEC61850 standard and the development and deployment of optoelectronic transformers, the concept of digital substations has been put into practical use ...[Details]
Current Development Status of DVR Market
A DVR, or digital video recorder, uses a hard disk for recording, unlike traditional analog video recorders. It's often called a DVR because it's a com...[Details]
When discussing autonomous driving technology, there are often two extremes: on the one hand, there's the vision of "fully autonomous driving," while on the other, there's concern about potential s...[Details]
Through AI connection technology supported by Qualcomm X85 5G modem and RF and Qualcomm FastConnect 7900 mobile connection system, seamless switching can be achieved between cellular net...[Details]
Coal mines typically contain gas and coal dust. When gas and coal dust reach a certain concentration, they can cause explosions. Electrical equipment generates arcs during normal operation or durin...[Details]
Bosch has released a new SoC series to support L2+ advanced driver assistance functions. The chip integrates high resolution and long-range detection capabilities, and has built-in support for neur...[Details]
The difference between a series inverter and a parallel inverter is that they use different oscillation circuits. A series inverter connects L, R, and C in series, while a parallel inverter connect...[Details]
Plug-in hybrid vehicles (PHEVs) utilize two powertrains. Their pure electric range is typically inferior to that of pure electric vehicles, often reaching less than half that. Currently, mainstream...[Details]
0 Introduction
With a rapidly aging population, a young couple is now required to care for an increasing number of elderly people, leading to a growing difficulty in providing care for them. E...[Details]
Blackfin® 16-/32-bit embedded processors offer high performance, low power consumption, flexible software features, and scalability, making them suitable for converged applications such as multi-fo...[Details]
The motor is a very important component for new energy vehicles. In terms of vehicle power, pure electric vehicles use electric motors instead of traditional diesel/gasoline engines. For electric v...[Details]
We know that the power output by the engine does not directly act on the wheels to drive the car, but needs to pass through a series of power transmission mechanisms. So how is the power transmitte...[Details]