Description
Circular Connector, 4 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,
CategoryThe connector   
File Size380KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

804-004-07M8-4SA Overview

Circular Connector, 4 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,

804-004-07M8-4SA Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialALUMINUM ALLOY
Housing size8
Termination typeCRIMP
Total number of contacts4
Base Number Matches1
A
B
C
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
Series 805
Series 805 “Mighty Mouse”
Triple-Start
Series 805 Receptacles
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, square flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose
integral
band platform
for direct attachment
of a cable shield. Install a boot,
or overmold a boot over the band
platform.
Gold-Plated Crimp Contacts
are held in place with beryllium
copper retention clips. Contacts are
removable.
Series 805 Triple-Start
Jam Nut Connector
An
accessory thread
is available
for attaching strain reliefs and
backshells.
HOW TO ORDER
Sample Part Number
80 5- 0 0 4
Series
-02
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
9-10
Shell Size- Insert
Arrangement
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
15-37
37 #23 Contacts
18-55
55 #23 Contacts
19-85
85 #23 Contacts
Size #23 contacts are
supplied with connectors.
Other contact sizes are
ordered separately.
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
A
Shell Key
Position
A
Position A
(Normal)
M
-01
805-003
Receptacle with
Banding Platform
In-Line
Aluminum / Electroless
Nickel
NF
Aluminum / Cadmium
with Olive Drab
Chromate
8-1
8-4
8-7
9-1
9-10
10-13
11-4
11-19
12-26
15-2
B
Position B
P
Pin
C
Position C
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
D
Position D
ZN
-02
Square Flange
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
805-004
Receptacle with
Accessory Thread
-07
Jam Nut for Rear
Panel Mounting
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
H-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
How can I isolate the analog signal front and back?
I want to use the on-chip AD to measure the standard signal (0-5V, 4-20mA) from the field.Without an isolation module, I want to ensure that the 430 will not be burned by the overcurrent and overvolta...
sje251 Microcontroller MCU
Moderator: Why does the RTC alarm function sometimes not enter an interrupt?
As the title says: My configuration is as follows. Sometimes when the program is downloaded, the flag is there but the RTC interrupt is not entered. The picture shows the value of the RTC register whe...
cfly stm32/stm8
Street Light Monitoring System "Photo Exhibition"
Why did the government purchase these things? I don't understand! Do you have engineering experience? I don't have such a small tool! How can I connect it on site! Damn. It also has an air switch, and...
1233211234567 Industrial Control Electronics
TMS320F28335 IO Control Timing Operation
IO Settings   2.1 Setting function   GPXMUX1/2: Function selection register     Each IO group of GPXMUX1/2generally has 32 IO ports that can be configured. GPXMUX1 corresponds to the lower 16 IO ports...
fish001 DSP and ARM Processors
A newbie asks for help! Ideas for a simple character drawing system and technical shortcomings
[i=s]This post was last edited by paulhyde on 2014-9-15 03:29[/i] As the title...
一条小菜鸟 Electronics Design Contest
Upgrading the constant temperature soldering station based on R7F0C80X microcontroller
[i=s]This post was last edited by zjw5000 on 2014-9-24 23:15[/i] [p=null, 2, center][size=6][b]Upgrading the Constant Temperature Soldering Station Based on R7F0C80X Microcontroller[/b][/size][/p] [fo...
zjw5000 Renesas Electronics MCUs

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2541  14  15  1432  2537  52  1  29  21  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号