Description
COPPER ALLOY, TIN FINISH, WIRE TERMINAL
CategoryThe connector    terminals   
File Size127KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

406434134 Overview

COPPER ALLOY, TIN FINISH, WIRE TERMINAL

406434134 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
ECCN codeEAR99
Manufacturer's serial numberWP91412
terminal genderFEMALE
Terminal and terminal strip typesWIRE TERMINAL
Base Number Matches1
Data Sheet
August 2007
WP91412 Connectors
The WP91412 Connectors are one-hole or
two-hole, tubular compression-type
terminators. They are available in straight, 45°
bend, or 90° bend configurations and are
intended for use with copper power wire sizes
ranging from 14 AWG to 750 kCMil.
They can be used with flexible power wires
classified as Class I stranding and standard
Class B stranding.
High Conductivity
The connectors are fabricated using seamless,
electrolytic wrought copper for excellent
conductivity and reliability; electro-tin plating
helps preserve connector integrity and also
prevents corrosion.
In addition, the connectors are specified for
extra margins of safety to minimize the risk of
overheating.
Easy, Accurate Installation
Intended for use in power equipment and
central office power system installations,
WP91412 Connectors are designed to be
installed using UL*- or CSA†-approved
compression tools and dies (as necessary).
The economical, standard length barrel is ideal
for space-restrictive applications.
To help reduce the incidence of errors and
ensure proper installation, a color-coding
scheme matches terminal and die sets to
provide the correct number and location of
crimps. Color-coded barrels are matched with
Class I and Class B stranding, which are
UL-listed with tooling, as indicated by the
specification.
The reliable, high-strength WP91412 Connectors
are designed for use with standard and flexible
stranded power wire used in power equipment or
central office applications.
®
Benefits
Provides highly reliable electromechanical
connections for high-energy applications
Minimizes the risk of overheating
Designed for fast, simplified, error-free
installation
Ensures high quality through strict testing and
qualification procedures
Meets applicable Telcordia requirements
UL-listed with Tyco KS power wires for Class I
stranding and standard Class B stranding
Suited for limited-space applications
Compatible with UL- or CSA-approved crimp
compression tools
UL-listed with tooling identified in the power data
sheets of the WP91412 specification
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of the Canadian Standards
Association.
CC2541 sensortag newbie needs guidance
I am a computer science student in my 2nd year. I participated in TI competitions a few years ago and TI gave me a lot of instruments including the cc2541 sensortag. I just downloaded the sensortag so...
小丿狼 Wireless Connectivity
The entire process of automobile design and manufacturing
For most people, the appreciation of cars is basically the whole car. In addition to performance, the appearance and interior of the car are the most talked about topics, because this is the most intu...
26979746 Automotive Electronics
Can the output voltage of an LDO be equal to the input voltage?
For a 5V output LDO, such as TPS73501, if the input is 5V, will the output be 5V? If the input is less than 5V, such as 4.7V, will the output still be a stable 5V? I know this design is not acceptable...
sfcsdc Analog electronics
[EVK-NINA-B400 Evaluation Kit] Unboxing
On May Day, I received the EVK-NINA-B400 evaluation kit from EE. The development board comes from u-blox AG, which is the Nordic region of Switzerland's U-blox AG. Thanks to EE Forum and U-blox!The BL...
ly87802541 RF/Wirelessly
Oscilloscope usage tips you don't know
As an effective tool used by engineers almost every day, the importance of oscilloscopes is beyond doubt. Especially with the application of new devices, the development of new technologies, and the i...
EE大学堂 Training Edition
I am a junior who has just started to learn about single-chip microcomputers. Question F of NUEDC uses MSP430 LAUNCHPAD to make a sine wave frequency display.
The input sine wave becomes a pulse wave after passing through the zero-crossing detection circuit. What should I do? I am just starting to learn about microcontrollers and I only know a little bit. P...
无央天空 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2363  1876  1774  1126  1912  48  38  36  23  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号