Angle Bracket, Angle Bracket Tapped, Without Angle Bracket
38330, 38336
p. 2-3
38540
p. 16-17
Shallow Bracket
38330
38542
Deep Bracket
38330, 38336
38540
p. 4-5
p. 18-19
p. 6-7
p. 20-21
Cable Mount Plugs and Sockets
Cable Clamp End
38331, 38336
38541
p. 8-9
p. 22-23
Cable Clamp Top, Cable Clamp Top with Keeper, Cable Clamp Top with Latch
38330, 38331, 38336
p. 10-11
p. 24-25
38541
Flared Hole End
38330, 38336
38540
Flared Hole Top
38330, 38331, 38336
38540
p. 12-13
p. 26-27
p. 14-15
p. 28-29
FEATURES AND SPECIFICATIONS
Features and Benefits
n
Sizes 2 to 33 circuits
n
Robust blade contacts resist damage from
improper mating
n
Large surface area of dual wipe female
contact produces maximum current
capacity
n
No de-rating required. All circuits rated for
full current load
n
Extra long pre-grounding contact engages
before any other contacts for greater safety.
Electrical
Voltage: 250V
Maximum Current:
10 Amp
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
Mechanical
Operating Temperature:
150
o
C
38330, 38336
Angled Bracket (AB)
Angle Bracket Tapped (ABT)
Less Angle Bracket (LAB)
Physical
Base Insulator: High-grade phenolic, black
Plug Contact: Brass
Plug Contact Plating: Tin
Socket Contact: Phosphor bronze
Socket Contact Plating: Tin
Pre-grounding Contact: Heavy-duty plated brass
SUGGESTED PANEL MOUNTING DIMENSIONS
CONTACT TAILS
Molex offers a wide selection of contact tails. Consult factory for
availablility and part numbers of other styles
Fig. D
Diameter
.156”
(3,96)
Reference Information
UL :
CSA:
File E34763
File 22156
.66”
(16,8)
38330-XX02
Diameter
.156”
(3,96)
.020”
(0,51)
Fig. E
.031”
(0,80)
Diameter
.156”
(3,96)
P Solder Eye (Standard)
.07” x .10”
(1,78 x 2,54)
.30”
(7,62)
.38”
(9,65)
P
7
Printed Circuit and
Wire Wrap, Short
.25”
(6,35)
.045” square
(1,14)
.97”
(24,6)
.078”
(1,98)
.44”
(11,1)
Diameter
.672”
(17,1)
38330-XX03-15
S
1
Quick Connect
.22”
(5,59)
Diameter
.156”
(3,96)
.06”
(1,59)
.44”
(11,1)
.110” x .020
(2,79 x 0,51)
P
1
Quick Connect
.39”
(9,91)
.110” x .020
(2,79 x 0,51)
Fig. F
Fig. G
Diameter
.156”
(3,96)
S Solder Eye (Standard)
.22”
(5,59)
1.015”
(25,8)
.07” x .10”
(1,78 x 2,54)
.25”
(6,35)
S
6
Printed Circuit
.10”
(2,54)
.03” x .04”
(0,76 x 1,02)
1.38”
(34,9)
38330-XX18-33
.06”
(1,59)
.032”
(0,81)
Diameter
.156”
(3,96)
1.375”
(34,9)
P
4
Wire Wrap, Long
.75” .63”
(19,1) (16,0)
.045” square
(1,14)
Diameter
.156”
(3,96)
Contact Orientation
The polarization arrangement numbers shown below are for sockets, as viewed from the wiring side. Plug numbering is the opposite. A heavy-duty polarizing/ground contact is in position 14 for Nos. 3324, 3327,
3330 and in position 17 for No. 3333. * Indicates location of pre-grounding contact. † Pregrounding contact is standard.
38330-XX02
38330-XX03
38330-XX04
38330-XX06
38336-8XXX
38330-XX08
38330-XX10
38330-XX12
38330-XX15 to 38330-XX21
38330-XX24 to 38330-XX30
38330-XX33
ORDERING INFORMATION AND DIMENSIONS
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
38330, 38336
Part #
in
3302*
3303
3304
3306
3306-8
3308
3310
3312
3315
3318
3321
3324
3327
3330
3333
0.66
1.00
0.75
1.00
1.00
1.25
1.56
1.25
1.63
1.94
2.25
2.56
2.88
3.19
3.50
T
mm
16,7
25,4
19,1
25,4
25,4
31,8
39,7
31,8
41,3
49,2
57,2
65,1
73,0
81,0
88,9
U
in
--
.44
.69
.69
.69
.69
.69
.94
1.00
1.00
1.00
1.00
1.00
1.00
1.00
V
mm
--
11,1
17,5
17,5
17,5
17,5
17,5
23,8
25,4
25,4
25,4
25,4
25,4
25,4
25,4
Part #
mm
32,1
27,0
33,3
33,3
33,3
33,3
33,3
39,7
42,9
42,9
42,9
42,9
42,9
42,9
42,9
3302*
3303
3304
3306
3306-8
3308
3310
3312
3315
3318
3321
3324
3327
3330
3333
Fig. #
in
D
E
F
E
E
F
F
F
F
G
G
G
G
G
G
.969
.750
1.000
1.000
1.000
1.000
1.000
1.250
1.375
1.250
.938
1.250
1.562
1.875
2.188
A
mm
24,6
19,1
25,4
25,4
25,4
25,4
25,4
31,8
34,9
31,8
23,8
31,8
39,7
47,6
55,6
B
in
--
1.016
.781
1.031
1.031
1.281
1.578
1.266
1.640
1.953
2.265
2.578
2.890
3.203
3.515
C
mm
--
25,8
19,8
26,2
26,2
32,5
40,1
32,2
41,7
49,6
57,5
65,5
73,4
81,4
89,3
in
1.27
1.06
1.31
1.31
1.31
1.31
1.31
1.56
1.69
1.69
1.69
1.69
1.69
1.69
1.69
in
--
.453
.719
.719
.719
.719
.719
.953
1.016
--
--
--
--
--
--
mm
--
11,5
18,3
18,3
18,3
18,3
18,3
24,2
25,8
--
--
--
--
--
--
PLUGS
Angle Bracket (-AB)
Order #
38330-0102
38330-0103
38330-0104
38330-0106
38336-8001
38330-0108
38330-0110
38330-0112
38330-0115
38330-0118
38330-0121
38330-0124
38330-0127
38330-0130
38330-0133
Engineering #
P-3302-AB
P-3303-AB
P-3304-AB
P-3306-AB
P-3306-8-AB
P-3308-AB
P-3310-AB
P-3312-AB
P-3315-AB
P-3318-AB
P-3321-AB
P-3324-AB
P-3327-AB
P-3330-AB
P-3333-AB
Angle Bracket Tapped (-ABT)
Order #
38330-1502
38330-1503
38330-1504
38330-1506
38336-8015
38330-1508
38330-1510
38330-1512
38330-1515
38330-1518
38330-1521
38330-1524
38330-1527
38330-1530
38330-1533
Engineering #
P-3302-ABT
P-3303-ABT
P-3304-ABT
P-3306-ABT
P-3306-8-ABT
P-3308-ABT
P-3310-ABT
P-3312-ABT
P-3315-ABT
P-3318-ABT
P-3321-ABT
P-3324-ABT
P-3327-ABT
P-3330-ABT
P-3333-ABT
Less Angle Bracket (-LAB)
Order #
38330-2202
38330-2203
38330-2204
38330-2206
38336-8022
38330-2208
38330-2210
38330-2212
38330-2215
38330-2218
38330-2221
38330-2224
38330-2227
38330-2230
38330-2233
Engineering #
P-3302-LAB
P-3303-LAB
P-3304-LAB
P-3306-LAB
P-3306-8-LAB
P-3308-LAB
P-3310-LAB
P-3312-LAB
P-3315-LAB
P-3318-LAB
P-3321-LAB
P-3324-LAB
P-3327-LAB
P-3330-LAB
P-3333-LAB
SOCKETS
Angle Bracket (-AB)
Order #
38330-0502
38330-0503
38330-0504
38330-0506
38336-8005
38330-0508
38330-0510
38330-0512
38330-0515
38330-0518
38330-0521
38330-0524
38330-0527
38330-0530
38330-0533
Engineering #
S-3302-AB
S-3303-AB
S-3304-AB
S-3306-AB
S-3306-8-AB
S-3308-AB
S-3310-AB
S-3312-AB
S-3315-AB
S-3318-AB
S-3321-AB
S-3324-AB
S-3327-AB
S-3330-AB
S-3333-AB
Angle Bracket Tapped (-ABT)
Order #
38330-1902
38330-1903
38330-1904
38330-1906
38336-8019
38330-1908
38330-1910
38330-1912
38330-1915
38330-1918
38330-1921
38330-1924
38330-1927
38330-1930
38330-1933
Engineering #
S-3302-ABT
S-3303-ABT
S-3304-ABT
S-3306-ABT
S-3306-8-ABT
S-3308-ABT
S-3310-ABT
S-3312-ABT
S-3315-ABT
S-3318-ABT
S-3321-ABT
S-3324-ABT
S-3327-ABT
S-3330-ABT
S-3333-ABT
Less Angle Bracket (-LAB)
Order #
38330-2602
38330-2603
38330-2604
38330-2606
38336-8026
38330-2608
38330-2610
38330-2612
38330-2615
38330-2618
38330-2621
38330-2624
38330-2627
38330-2630
38330-2633
Engineering #
S-3302-LAB
S-3303-LAB
S-3304-LAB
S-3306-LAB
S-3306-8-LAB
S-3308-LAB
S-3310-LAB
S-3312-LAB
S-3315-LAB
S-3318-LAB
S-3321-LAB
S-3324-LAB
S-3327-LAB
S-3330-LAB
S-3333-LAB
FEATURES AND SPECIFICATIONS
Features and Benefits
n
Sizes 15 to 33 circuits
n
Robust blade contacts resist damage
fromimproper mating
n
Large surface area of dual wipe female
contact produces maximum current
capacity
n
No de-rating required. All circuits rated
for full current load
n
Extra long pre-grounding contact
engages before any other contacts for
greater safety.
Electrical
Voltage: 250V
Maximum Current: 10 Amp
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
Mechanical
Operating Temperature:
150
o
C
38330
Shallow Bracket (SB)
Physical
Base Insulator:High-grade phenolic, black
Plug Contact: Brass
Plug Contact Plating: Tin
Socket Contact: Phosphor bronze
Socket Contact Plating: Tin
Pre-grounding Contact: Heavy-duty plated brass
SUGGESTED PANEL MOUNTING DIMENSIONS
CONTACT TAILS
Molex offers a wide selection of contact tails. Consult factory for
availablility and part numbers of other styles
Reference Information
UL :
CSA:
File E34763
File 22156
.032”
(0,81)
Fig. K
1.08”
(27.4)
P Solder Eye (Standard)
.07” x .10”
(1,78 x 2,54)
.30”
(7,62)
P
7
Printed Circuit and
Wire Wrap, Short
.25”
(6,35)
.38”
(9,65)
.045” square
(1,14)
1.38”
(34.9)
.44”
(11,1)
Diameter
.187”
(4,75)
S
1
Quick Connect
.22”
(5,59)
.110” x .020
(2,79 x 0,51)
P
1
Quick Connect
.39”
(9,91)
.110” x .020
(2,79 x 0,51)
S Solder Eye (Standard)
.22”
(5,59)
Diameter
.190”
(4.83)
.07” x .10”
(1,78 x 2,54)
.25”
(6,35)
S
6
Printed Circuit
.10”
(2,54)
.03” x .04”
(0,76 x 1,02)
P
4
Wire Wrap, Long
.75” .63”
(19,1) (16,0)
.045” square
(1,14)
Contact Orientation
The polarization arrangement numbers shown below are for sockets, as viewed from the wiring side. Plug numbering is the opposite. A heavy-duty polarizing/ground contact is in position 14 for Nos. 3324, 3327,
I want to use MSP430G2231 to control a DAC through SPI bus, but I can't program it successfully. The main reason is that I don't know how to configure the USI register. Please help me....
Although the M3 issue has been discussed for a long time, our company’s delivery time was originally normal, but it has become tight recently. I wonder if other friends have encountered such a problem...
The mouse I got as a prize from EE in the early years has a little bit of key binding these days. I'm a bit annoyed recently and I'm too lazy to change the keys, so I just use the E coins to buy a big...
Mu is a cross-platform editor suitable for developers who like simplicity. It only has the most basic core functions, no complicated interface and settings, and no various plug-ins. It is optimized fo...
The TIA Portal software's shift instructions shift the contents of an accumulator bit by bit to the left or right. The number of bits shifted is determined by N. A left shift of N bits multiplies t...[Details]
On August 24th, Tesla CEO Elon
Musk
revealed information about the upcoming FSD V14, claiming it will outperform human drivers. Tesla FSD lead Ashok stated last year that FSD version 12.5, ...[Details]
The intelligent driving community has its own rhythm. Some are busy pushing new versions and focusing on R&D, others are busy with publicity and promotion, and still others are immersed in mass pro...[Details]
New energy vehicles are increasingly popular with consumers due to policies and energy conservation. Once you've purchased your vehicle, maintenance is essential. However, due to the different powe...[Details]
On August 25th, TSMC, the world's leading contract chip manufacturer, attracted significant attention for its decision to build a chip manufacturing facility in Arizona. TSMC primarily manufactures...[Details]
On August 25th, Apple's expansion in India encountered new troubles. According to Bloomberg, Foxconn Technology Group has recalled approximately 300 Chinese engineers from India, further hindering ...[Details]
According to foreign media reports, secondary battery materials company POSCO Future M announced that it has successfully developed two experimental (prototype) positive electrode materials for the...[Details]
For autonomous vehicles to safely navigate the road, they must identify far more complex objects than just traffic lights, pedestrians, and other familiar objects. Among these obstacles is a crucia...[Details]
This paper proposes a temperature real-time transmission and display solution based on LED optical data transmission, with Jingwei Yager low-power FPGA HR (Yellow River) series as the main controll...[Details]
The digital TV set-top box consists of a tuner, QAM demodulator, TS demultiplexer, MPEG-2 decoder, PAUNTSC video encoder, embedded CPU system and peripheral interfaces, CA module, and uplink data m...[Details]
Keysight Technologies is combining its electromagnetic simulator with Synopsys' AI-driven RF design migration flow to create an integrated design flow for migrating from TSMC's N6RF+ process techno...[Details]
1. Ease of Use: The HMI module should be designed to be simple and clear, allowing users to easily operate and configure the energy storage device.
2. Ease of Maintenance: The HMI module should...[Details]
On August 22, according to CNBC's report today, the National Highway Traffic Safety Administration (NHTSA) is launching an investigation into Tesla, and the latter is questioned whether it has fail...[Details]
Plessey Semiconductors has been acquired by Haylo Labs, which was established in March last year with a $100 million, five-year loan from Chinese technology company Goertek.
Haylo Labs w...[Details]
The difference between a series inverter and a parallel inverter is that they use different oscillation circuits. A series inverter connects L, R, and C in series, while a parallel inverter connect...[Details]