14-Pin SO (derate 8.3mW/°C above +70°C)..............667mW
Operating Temperature Range .........................-40°C to +125°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
µMAX is a registered trademark of Maxim Integrated products, Inc.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
DC ELECTRICAL CHARACTERISTICS
(V
CC
= +5V, V
EE
= -5V, R
L
= 100kΩ to ground, T
A
= -40°C to +125°C. Typical values are at T
A
= +25°C, unless otherwise noted.)
(Note 1)
PARAMETER
Operating Supply Voltage
Range
Quiescent Supply Current per
Amplifier
Input Offset Voltage
Input Offset Voltage Drift
Input Offset Voltage Channel
Matching
Input Bias Current
Input Offset Current
Input Resistance
Common-Mode Input Voltage
Range
Common-Mode Rejection Ratio
Power-Supply Rejection Ratio
Large-Signal Voltage Gain
I
B
I
OS
Differential mode (-1V
≤
V
IN
≤
+1V)
R
IN
Common mode (V
EE
- 0.2V
≤
V
CM
≤
V
CC
-
1.5V)
Guaranteed by CMRR test
V
EE
- 0.2V
≤
V
CM
≤
V
CC
- 1.5V
V
S
=
±2.25V
to
±5.5V
R
L
= 100kΩ, V
EE
+ 0.25V
≤
V
OUT
≤
V
CC
-
0.25V
R
L
= 1kΩ, V
EE
+ 0.5V
≤
V
OUT
≤
V
CC
- 0.5V
Output Voltage Swing
Output Short-Circuit Current
V
OUT
I
SC
R
L
= 100kΩ, V
CC
- V
OH
and V
OL
- V
EE
R
L
= 1kΩ, V
CC
- V
OH
and V
OL
- V
EE
Sourcing or sinking
V
EE
-
0.2V
65
65
85
65
90
80
110
90
10
200
15
150
450
mV
mA
SYMBOL
V
S
I
S
V
OS
TCV
OS
MAX4494 and MAX4495
T
A
= +25°C
T
A
= T
MIN
to T
MAX
3
1
0.2
5
250
110
V
CC
-
1.5V
1
300
CONDITIONS
Guaranteed by PSRR test
MIN
±2.25
770
0.3
TYP
MAX
±5.5
1100
5
10
UNITS
V
µA
mV
µV/°C
mV
µA
nA
kΩ
MΩ
V
dB
dB
dB
V
CM
CMRR
PSRR
A
VOL
Note 1:
All devices are 100% production tested at T
A
= +25°C. Limits over the operating temperature range are guaranteed by
==S 投票==E 投票
S 文章(这部分加style只是为了看效果,基本上表现都受编辑器设置控制)RC charging calculation method
Reprinted from: http://hi.baidu.com/cumtsun/blog/item/b8ee5f16561cae4e20a4e93c.htmlExample 1 : As shown in the figure, ...
Whether it is high or low, the relay will work. When it is high, the voltage difference between the 3rd and 4th pins of the optocoupler is 10V, and the relay is 24V. Shouldn't it be 0 when it is high?...
Hello everyone, I have a few questions to ask you. I am studying the Bluetooth device of embedded system recently. The CPU used is s3c2443, and the OS is WinCE Platform Builder 5.0. I want to build a ...
Now I have a large constant array const int testdata[1000]. In order to save memory, I want to put it in the code segment. How do I declare it? In the past, in the microcontroller, the bytes were simp...
The problem of HPS accessing the i/o port of FPGA through the HPS-to-FPGA bridge. It is not a lightweight bridge. Has anyone done it before? I have been working on it for two days, but it doesn't work...
Dear heroes, the clock of the crystal oscillator is main_clk. After dividing the clock, we get the AD clock AD_clk. However, in the actual circuit diagram, I connected AD_clk to the pin corresponding ...
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
Power management solutions for today's portable application processors are becoming increasingly integrated. Total power consumption, standby and sleep current consumption affect battery size, bill...[Details]
The data collector of the automatic weather station is generally designed based on a single-chip microcomputer or a PC/104 bus controller. It has the characteristics of good compatibility with PC, low...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
Capacitance Measurement
Used to verify that capacitors meet the manufacturer's specifications. For quality control, a group of capacitors may be placed in an environmental chamber and the cap...[Details]
Introduction
Automakers are working to reduce vehicle weight to reduce CO2 emissions and improve fuel efficiency. Designers are therefore seeking new technologies and design techniques that can...[Details]
To understand how and why OLED power supply affects display image quality, you must first understand OLED display technology and power supply requirements. This article will explain the latest OLED...[Details]
introduction
Incandescent bulbs can emit a variety of light, but in specific applications, only green, red, and yellow light are usually needed - such as traffic lights. If an incand...[Details]
0 Introduction
Under normal circumstances, the three-phase power in the power system is symmetrical, and they meet certain amplitude and phase conditions; but when the load changes, the syst...[Details]
The above is to use MB1404 as a stereo composite signal transmitter. You can use the internal high-frequency amplifier and oscillator or not! According to my experience, I still recommend beginners...[Details]
The invention of the steam engine ushered in the first conversion of internal energy and mechanical energy for mankind, and the birth of the internal combustion engine at the end of the 19th centur...[Details]
1 What is an LED floodlight?
LED downlights are also called spotlights, projection lamps, and spotlights. They are mainly used for architectural decorative lighting and commercial space lighti...[Details]
store
To prevent moisture, LEDs should be stored in a dry and ventilated environment with a storage temperature of -40°C to +100°C and a relative humidity below 85%.
The LED should be use...[Details]