EEWORLDEEWORLDEEWORLD

Part Number

Search

8218JN

Description
DC Fans DC Tubeaxial Fan, 80x80x38mm, 48VDC, 77.7CFM, 11W, 8400RPM, 55dBA, Ball Bearing
CategoryThermal management products    Heat resisting bracing   
File Size193KB,1 Pages
Manufacturerebm-papst
Websitehttp://www.ebmpapst.com
Download Datasheet Parametric View All

8218JN Online Shopping

Suppliers Part Number Price MOQ In stock  
8218JN - - View Buy Now

8218JN Overview

DC Fans DC Tubeaxial Fan, 80x80x38mm, 48VDC, 77.7CFM, 11W, 8400RPM, 55dBA, Ball Bearing

8218JN Parametric

Parameter NameAttribute value
Makerebm-papst
Reach Compliance Codecompliant
Heat Resistant Support Device TypeDC FAN
Base Number Matches1
Max.
222
m /h
3
DC axial fans
80 x 38 mm
– Material:
Housing: GRP
1)
(PBT)
Impeller: GRP
1)
(PA)
Direction of air flow:
Exhaust over struts
Direction of rotation:
Counterclockwise,
looking towards rotor
Connection:
Via single wires AWG 24
(H3 and H4: AWG 22), TR 64
Weight:
160 g (H3 and H4: 200 g)
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Moisture protection
- Degree of protection:IP 54
1) Fiberglass-reinforced plastic
Sintec sleeve bearings
Ball bearings
Temperature range
Nominal voltage
Sound power level
Series 8200 J
Life expectancy
L
10IPC
(40 °C) see page 17
Sound pressure level
Service life L10 (40 °C)
ebm-papst standard
Service life L10 (Tmax)
ebm-papst standard
Power consumption
Nominal speed
Voltage range
Air flow
Air flow
Type
8212 JN
8212 JH3
8212 JH4
8214 JN
8214 JH3
8214 JH4
8218 JN
8218 JH3
8218 JH4
Subject to change
m
3
/h
132
190
222
132
190
222
132
190
222
cfm
78
112
131
78
112
131
78
112
131
VDC
12
12
12
24
24
24
48
48
48
VDC
7...13.8
6...13.8
6...13.8
18...26.4
12...27.6
12...27.6
36...53
36...53
20...58
dB(A) Bel(A)
55
66
71
55
66
71
55
66
71
6.6
7.3
7.8
6.6
7.3
7.8
6.6
7.3
7.8
/
Watts
10
26*
39*
11
26*
38*
11
25*
36*
rpm
-1
8 400
12 000
14 000
8 400
12 000
14 000
8 400
12 000
14 000
°C
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
Hours
62 500 / 32 500
55 000 / 27 500
50 000 / 25 000
62 500 / 32 500
55 000 / 27 500
50 000 / 25 000
62 500 / 32 500
55 000 / 27 500
50 000 / 25 000
Hours
105 000
92 500
85 000
105 000
92 500
85 000
105 000
92 500
85 000
¿
¡
¬
¿
¡
¬
¿
¡
¬
47
2016-01
Finger guards
from p. 242
Representatives
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L
W
A ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance from
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Tin-p
la
ted
Accessories
AC centrifugal fans
AC axial fans
8200 JH3 and JH4 also available as standard with PWM control input and speed signal.
Speed control range from 2000 rpm
-1
up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted.
* Power consumption at free air flow. These values can be significantly higher in the operating point.
ACmaxx / EC fans
DC fans - specials
Nominal data
Curve
DC centrifugal fans
DC axial fans
Information
Inspection Basis for Type Approval Testing of Radio Transmitter Equipment (including reference standards)
Inspection Basis for Type Approval Testing of Radio Transmitter Equipment (including reference standards)...
xtss RF/Wirelessly
Clock made of digital tube: It seems that it is impossible to add an alarm!
Clock made with digital tubes: It seems that the alarm function cannot be added! The reason is: it conflicts with the display! Is this true? Has anyone made one?...
89cpu MCU
Ask questions + discuss the problem of op amp clamping diode
[i=s]This post was last edited by dontium on 2015-1-23 11:39[/i] When using an op amp, if the op amp input does not have a clamping diode, many people like to add an external clamping diode as shown i...
jishuaihu Analogue and Mixed Signal
TI application engineers show you how to use smart sockets! ! ! (multiple pictures)
[flash]http://player.youku.com/player.php/sid/XMjg3MzExMzcy/v.swf[/flash] It is said that laptops consume less power? But is it really less? No one has carefully measured it. This time, let's take a l...
EEWORLD社区 Microcontroller MCU
Zigbee Zigbee purchases from Texas, which category should I choose when entering China?
[size=5]When buying Zigbee from Texas, which category should I choose for customs clearance to enter China? [/size]...
kuangdg Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1822  2528  500  1516  360  37  51  11  31  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号