max.
57
m3/h
AC axial fans
Series 8000 A
–
–
–
–
–
–
–
–
–
80 x 80 x 38 mm
AC fans with external rotor shaded-pole motor. Impedance protected against overloading.
Metal fan housing and impeller.
Air intake over struts. Direction of rotation clockwise, seen on rotor.
Electrical connection via 2 flat plugs 2.8 x 0.5 mm.
Fan housing with grounding lug and screw M4 x 8 (TORX).
Mass: 490 g.
Optionally available with electrical connection via leads.
Optionally available with air exhaust over struts and clockwise direction of rotation.
Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Sound pressure level
Sintec sleeve bearings
Ball bearings
Sound power level
Nominal voltage
Temperature range
Frequency
Nominal speed
Service life L10
at 40 °C
Power input
Air flow
Air flow
at T max
Nominal data
Type
8880 A
8850 A
8550 A
8556 A
8830 A
8800 A
8500 A
8506 A
m3/h
29
36
48
48
34
45
57
57
CFM
17,1
21,2
28,3
28,3
20,0
26,5
33,5
33,5
V
230
230
230
230
115
115
115
115
Hz
50
50
50
50
60
60
60
60
dB(A)
26
31
36
37
29
34
41
42
Bel(A)
4,1
4,6
5,0
5,1
4,3
4,8
5,5
5,7
/
Watts
9,0
12,5
12,0
12,0
8,0
11,0
11,0
11,0
RPM
1 750
2 150
2 700
2 800
1 950
2 500
3 200
3 300
°C
-10...+80
-10...+70
-10...+70
-40...+90
-10...+80
-10...+70
-10...+75
-40...+95
Hours
Hours
1
2
3
3
4
5
6
6
/
/
/
/
/
/
/
/
60 000 / 25 000
52 500 / 25 000
52 500 / 25 000
52 500 / 15 000
62 500 / 25 000
55 000 / 27 500
55 000 / 25 000
55 000 / 15 000
Series 8000 A with
reinforced flanges
0,15
40
[in H
2
O]
Pa
3
6
30
0,10
20
0,05
2
5
10
1
4
0
5
10
15
20
25
30
CFM
m³/h
60 Hz
10
20
30
40
50 Hz
50
144
HP
IP54
Û
S
P
Curve