Max.
102
m /h
3
DC axial fans
92 x 25 mm
– Material:
–
–
–
–
Housing: GRP
1)
(PBT)
Impeller: GRP
1)
(PA)
Direction of air flow:
Exhaust over struts
Direction of rotation:
Counterclockwise,
looking towards rotor
Connection:
Via single wires AWG 24,
TR 64
Weight:
100 g
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Moisture protection
- Degree of protection: IP 54 / IP 68
1) Fiberglass-reinforced plastic
Sintec sleeve bearings
Ball bearings
Temperature range
Nominal voltage
Sound power level
Series 3400 N
Life expectancy
L
10IPC
(40 °C) see page 17
Sound pressure level
Service life L10 (40 °C)
ebm-papst standard
Power consumption
Nominal speed
Voltage range
Air flow
Air flow
Service life L10 (Tmax)
ebm-papst standard
Nominal data
Type
3412 NGLE
3412 NLE
3412 NGME
3412 NME
3412 NG
3412 N
3412 NGH
3412 NH
3412 NGHH
3412 NHH
3412 NHH-379
3414 NGL
3414 NL
3414 NGM
3414 NM
3414 NG
3414 N
3414 NGH
3414 NH
3414 NGHH
3414 NGHH-389
3414 NHH
3414 NHH-386
3418 N
m
3
/h
61
61
72
72
84
84
94
94
102
102
102
61
61
72
72
84
84
94
94
102
102
102
102
84
cfm
35.9
35.9
42.4
42.4
49.4
49.4
55.3
55.3
60.0
60.0
60.0
35.9
35.9
42.4
42.4
49.4
49.4
55.3
55.3
60.0
60.0
60.0
60.0
49.4
VDC
12
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
24
24
24
48
VDC
8...15
8...15
8...15
8...15
8...15
8...15
8...15
8...15
8...13.2
8...13.2
8...15
18...28
18...28
18...28
18...28
18...28
18...28
18...26
18...26
18...26
18...28
18...26
18...28
36...56
dB(A) Bel(A)
23
23
28
28
32
32
36
36
39
39
39
23
23
28
28
32
32
36
36
39
39
39
39
32
4.0
4.0
4.3
4.3
4.7
4.7
5.0
5.0
5.1
5.1
5.1
4.0
4.0
4.3
4.3
4.7
4.7
5.0
5.0
5.1
5.1
5.1
5.1
4.7
/
Watts
1.1
0.8
1.6
1.1
1.9
1.7
2.3
2.1
3.2
2.9
2.7
1.4
1.1
1.7
1.4
2.5
2.1
3.0
2.3
3.2
3.2
3.1
3.2
2.4
rpm
-1
1 950
1 950
2 300
2 300
2 700
2 700
3 000
3 000
3 250
3 250
3 250
1 950
1 950
2 300
2 300
2 700
2 700
3 000
3 000
3 250
3 250
3 250
3 250
2 700
°C
-20...+80
-20...+85
-20...+75
-20...+75
-20...+70
-20...+70
-20...+70
-20...+70
-20...+60
-20...+60
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
Hours
80 000 / 22 500
80 000 / 17 500
75 000 / 27 500
75 000 / 27 500
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 45 000
70 000 / 45 000
70 000 / 35 000
80 000 / 40 000
80 000 / 40 000
75 000 / 37 500
75 000 / 37 500
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
Hours
135 000
135 000
127 500
127 500
117 500
117 500
117 500
117 500
117 500
117 500
117 500
135 000
135 000
127 500
127 500
117 500
117 500
117 500
117 500
117 500
117 500
117 500
117 500
117 500
¿
¿
¡
¡
¬
¬
√
√
ƒ
ƒ
ƒ
¿
¿
¡
¡
¬
¬
√
√
ƒ
ƒ
ƒ
ƒ
¬
Other 48 VDC models on request.
Tin-p
la
ted
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L
W
A ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see