DC Fans DCFan200.87CFM21.12W 24V 120x120x38 AR/TS
CategoryThermal management products   
File Size709KB,6 Pages
ManufacturerCUI Inc.
Environmental Compliance
Download Datasheet Parametric View All

CFM-A238-23-20 Online Shopping

Suppliers Part Number Price MOQ In stock  
CFM-A238-23-20 - - View Buy Now

CFM-A238-23-20 Overview

DC Fans DCFan200.87CFM21.12W 24V 120x120x38 AR/TS

CFM-A238-23-20 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerCUI Inc.
Product CategoryDC Fans
RoHSDetails
Operating Supply Voltage24 VDC
Airflow200.9 CFM
Speed4600 RPM
Pressure Type19.8 mm H2O
Bearing TypeBall
Noise61.5 dBA
FeaturesAuto restart protection
Height38 mm
Length120 mm
ProductDC Fans
Width120 mm
Current TypeDC
Height - in1.496
Height - mm38
Length - in4.724
Length - mm120
Factory Pack Quantity10
Width - in4.724
Width - mm120
Unit Weight10.007223 oz
For more information, please visit the
product page.
date
page
07/27/2017
1 of 6
SERIES:
CFM-120
DESCRIPTION:
DC AXIAL FAN
FEATURES
• 120 x 120 mm frame
• high fan speed for greater air flow
• dual ball bearing construction
• auto restart protection standard on all models
MODEL
rated
(Vdc)
input
voltage
range
(Vdc)
typ
(A)
input
current
max
(A)
input
power
max
(W)
rated
speed
typ
(RPM)
air
flow
1
(CFM)
static
pressure
2
(inch H
2
O)
noise
max
(dBA)
CFM-A225-13
CFM-A225-23
CFM-A225-43
CFM-A238-13
CFM-A238-23
CFM-A238-43
Notes:
12
24
48
12
24
48
6~13.8
16~27.6
30~55.2
6~13.8
16~27.6
30~55.2
0.59
0.31
0.17
1.40
0.77
0.36
0.79
0.39
0.23
1.75
0.88
0.48
9.48
9.36
11.04
21
21.12
23.04
4,100
4,100
4,100
4,600
4,600
4,600
126.89
126.89
126.89
200.9
200.9
200.9
0.49
0.49
0.49
0.78
0.78
0.78
53.5
53.5
53.5
61.5
61.5
61.5
1. At 0 inch H
2
0 static pressure.
2. At 0 CFM airflow.
PART NUMBER KEY
CFM-A2
XX
-
X
3 -
XX
-
CXX
Base Number
Depth
25 = 25 mm
38 = 38 mm
Reserved for Custom
Configurations
Input Voltage
1 = 12 Vdc
2 = 24 Vdc
4 = 48 Vdc
Fan Signals
10 = no signals
11 = rotation detector signal
20 = tachometer signal
22 = tachometer signal / PWM control signal
cui.com
Research on battery charging method
Abstract: According to the characteristics of batteries, the polarization phenomenon during the charging and discharging process of batteries is studied, several charging methods are proposed and anal...
zbz0529 Embedded System
What does the statement move=(move<<1)|0x01 mean?
I am new to C language, and I am asking a question on behalf of my classmates. Haha, the question is as the title says.I would like to ask forum friends to explain it! ! Thank you...
lalaone MCU
Can anyone tell me about the research on FPGA chip EPCS4?
[i=s] This post was last edited by paulhyde on 2014-9-15 04:22 [/i] How does his active configuration method work?...
sonic1007 Electronics Design Contest
Controllable Paper Plane--PowerUp
Earlier this year, a very cool toy "accessory" called PowerUp was exhibited at the American International Toy Fair. You can control the paper airplane to fly freely in the sky directly using your smar...
qinkaiabc Creative Market
2440 LCD Problem
The LCD model is LTV250QV-F05, which uses IO port to simulate SPI bus. Through serial port printing, we can see that the system is up, but the screen is white. There is no problem with the hardware. T...
z4126 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2607  2016  2720  826  2092  53  41  55  17  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号