EEWORLDEEWORLDEEWORLD

Part Number

Search

9G0824G1D011

Description
DC Fans Fan, 80x38mm, 24VDC Ribless, Lock Sensor
CategoryThermal management products   
File Size165KB,3 Pages
ManufacturerSanyo Denki
Environmental Compliance
Download Datasheet Parametric View All

9G0824G1D011 Online Shopping

Suppliers Part Number Price MOQ In stock  
9G0824G1D011 - - View Buy Now

9G0824G1D011 Overview

DC Fans Fan, 80x38mm, 24VDC Ribless, Lock Sensor

9G0824G1D011 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerSanyo Denki
Product CategoryDC Fans
RoHSDetails
TypeAxial
Frame Dimensions - mm80 mm L x 38 mm W x 80 mm H
Operating Supply Voltage24 VDC
Airflow90.04 CFM
Speed6300 RPM
Pressure Type21 mmAq
Noise51 dBA
Housing MaterialPlastic
Termination StyleWire Leads
PackagingBulk
Height80 mm
Length80 mm
ProductDC Fans
Size80 mm
Width38 mm
Current TypeDC
ComplianceCSA; TUV; UL
Factory Pack Quantity27
DC Fan
80
×
80
×
38
mm
San Ace 80 9G
type
General Specifications
Material
…………………………………………
Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0)
Expected life
……………………………………
See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C,
Motor protection function
…………………
Dielectric strength
……………………………
Insulation resistance
…………………………
Sound pressure level (SPL)
………………
Storage temperature
………………………
Lead wire
………………………………………
rated voltage)
Locked rotor burnout protection, Reverse polarity protection
For details, please refer to p. 529.
50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
At 1 m away from the air inlet
-30 to +70˚C (Non-condensing)
Black
Sensor
Red
Mass
………………………………………………
170 g
Yellow
Specifications
The models listed below
have ribs and pulse sensors.
For models without ribs, append "1" to the end of model numbers.
Model no.
Rated voltage Operating voltage range Rated current Rated input
[V]
[V]
[A]
[W]
Rated speed
[min
-1
]
Max. airflow
[m³/min]
[CFM]
Max. static pressure
[Pa]
SPL
[dB (A)]
Operating temperature Expected life
[˚C]
[h]
9G0812K101
9G0812G101
9G0812H101
9G0824G101
9G0824H101
9G0848G101
9G0848H101
10.8 to 13.2
12
24
48
7 to 13.8
20.4 to 27.6
40.8 to 55.2
1.8
1.1
0.9
0.56
0.42
0.27
0.2
21.6
13.2
10.8
13.4
10.1
13.0
9.6
7800
6300
5700
6300
5700
6300
5700
3.1
2.55
2.28
2.55
2.28
2.55
2.28
107.3
90
80
90
80
90
80
310
211
171
211
171
211
171
[inchH²O]
1.285
0.847
0.687
0.847
0.687
0.847
0.687
58
51
49
51
49
51
49
-
20 to
+
60
-
20 to
+
70
40000/60˚C
Other sensor specifications are available as options. Refer to the index (p. 549).
Airflow - Static Pressure Characteristics
9G0812K101
With pulse sensor
9G0812G101
With pulse sensor
9G0812H101
With pulse sensor
Operating voltage range
(inch H
2
O) (Pa)
Operating voltage range
(inch H
2
O) (Pa)
Operating voltage range
(inch H
2
O) (Pa)
1.4
1.2
350
300
250
200
150
100
50
0
0
0.5 1 1.5 2.0 2.5 3.0 3.5
(m
3
/min)
20 40 60 80 100 120
Static
静圧
pressure
1.0
0.8
0.6
0.4
0.2
0
Static
静圧
pressure
静圧
Static pressure
13.2 V
12 V
10.8 V
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.5 1.0 1.5 2.0 2.5 3.0
20
(m
3
/min)
13.8 V
12 V
7V
0
220
200
180
160
140
120
100
80
60
40
20
0
0
13.8 V
12 V
7V
0.5 1.0 1.5 2.0 2.5 3.0
(m
3
/min)
20
Airflow
風量
(CFM)
Airflow
風量
40
60
80 100 120
(CFM)
Airflow
風量
40
60
80 100
(CFM)
138
【MSP430 Sharing】MSP430 binary disassembly tool
Interested friends can share how to use it and their experience.......
hangsky Microcontroller MCU
The company is recruiting LAYOUT hardware engineers. Not an agency.
The company is hiringJob content:1. Schematic design2. PCB layout3. Sample debuggingJob requirements:1. Love your job, be dedicated, and be serious and careful.2. Have an electronic foundation and be ...
薇薇安雪雪 Talking about work
I want to use a single-chip microcomputer to make a remote control curtain, but I don't have any ideas. Experts, please give me some advice.
I want to use a single-chip microcomputer to make a remote control curtain, but I don't have any ideas. Experts, please give me some advice. Thank you....
lonely_boy MCU
Measuring the tilt angle of a pendulum
I hope you can give me some suggestions: I want to measure the tilt angle of a vertical pendulum and alarm when it tilts to a certain angle. How should I design it?...
洗了八吨水 Embedded System
Is it necessary to take a postgraduate entrance examination to work in embedded systems?
I am a junior in electronic information engineering. I have read some information about embedded systems online and plan to work in this field. I have not yet decided which level I will work in. Do yo...
gina Embedded System
Design of a single bus single chip multi-machine communication system
Traditional multi-machine communication systems generally require four wires: 1. Power line; 2. Ground line; 3. Send signal line; 4. Receive signal line. However, for systems with a long distance betw...
clj2004000 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 184  415  618  957  624  4  9  13  20  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号