3412NG

Description
DC Fans DC Tubeaxial Fan, 92x92x25mm, 12VDC, 49.4CFM, 32dBA, 2.2W, 2700RPM, Sleeve Bearing, Sensor Signal
CategoryThermal management products    Heat resisting bracing   
File Size127KB,1 Pages
Manufacturerebm-papst
Websitehttp://www.ebmpapst.com
Environmental Compliance
Download Datasheet Parametric View All

3412NG Online Shopping

Suppliers Part Number Price MOQ In stock  
3412NG - - View Buy Now

3412NG Overview

DC Fans DC Tubeaxial Fan, 92x92x25mm, 12VDC, 49.4CFM, 32dBA, 2.2W, 2700RPM, Sleeve Bearing, Sensor Signal

3412NG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompliant
air flow volume49.44 CFM
Bearing typeSLEEVE
structureAXIAL
high92 mm
length92 mm
life expectancy140000 h
noise32 dB
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
rated power2.2 W
Rated voltage12 V
speed2700 rpm
Heat Resistant Support Device TypeDC FAN
weight100 g
width25 mm
Base Number Matches1
Max.
102
m /h
3
DC axial fans
92 x 25 mm
– Material:
Housing: GRP
1)
(PBT)
Impeller: GRP
1)
(PA)
Direction of air flow:
Exhaust over struts
Direction of rotation:
Counterclockwise,
looking towards rotor
Connection:
Via single wires AWG 24,
TR 64
Weight:
100 g
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Moisture protection
- Degree of protection: IP 54 / IP 68
1) Fiberglass-reinforced plastic
Sintec sleeve bearings
Ball bearings
Temperature range
Nominal voltage
Sound power level
Series 3400 N
Life expectancy
L
10IPC
(40 °C) see page 17
Sound pressure level
Service life L10 (40 °C)
ebm-papst standard
Power consumption
Nominal speed
Voltage range
Air flow
Air flow
Service life L10 (Tmax)
ebm-papst standard
Nominal data
Type
3412 NGLE
3412 NLE
3412 NGME
3412 NME
3412 NG
3412 N
3412 NGH
3412 NH
3412 NGHH
3412 NHH
3412 NHH-379
3414 NGL
3414 NL
3414 NGM
3414 NM
3414 NG
3414 N
3414 NGH
3414 NH
3414 NGHH
3414 NGHH-389
3414 NHH
3414 NHH-386
3418 N
m
3
/h
61
61
72
72
84
84
94
94
102
102
102
61
61
72
72
84
84
94
94
102
102
102
102
84
cfm
35.9
35.9
42.4
42.4
49.4
49.4
55.3
55.3
60.0
60.0
60.0
35.9
35.9
42.4
42.4
49.4
49.4
55.3
55.3
60.0
60.0
60.0
60.0
49.4
VDC
12
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
24
24
24
48
VDC
8...15
8...15
8...15
8...15
8...15
8...15
8...15
8...15
8...13.2
8...13.2
8...15
18...28
18...28
18...28
18...28
18...28
18...28
18...26
18...26
18...26
18...28
18...26
18...28
36...56
dB(A) Bel(A)
23
23
28
28
32
32
36
36
39
39
39
23
23
28
28
32
32
36
36
39
39
39
39
32
4.0
4.0
4.3
4.3
4.7
4.7
5.0
5.0
5.1
5.1
5.1
4.0
4.0
4.3
4.3
4.7
4.7
5.0
5.0
5.1
5.1
5.1
5.1
4.7
/
Watts
1.1
0.8
1.6
1.1
1.9
1.7
2.3
2.1
3.2
2.9
2.7
1.4
1.1
1.7
1.4
2.5
2.1
3.0
2.3
3.2
3.2
3.1
3.2
2.4
rpm
-1
1 950
1 950
2 300
2 300
2 700
2 700
3 000
3 000
3 250
3 250
3 250
1 950
1 950
2 300
2 300
2 700
2 700
3 000
3 000
3 250
3 250
3 250
3 250
2 700
°C
-20...+80
-20...+85
-20...+75
-20...+75
-20...+70
-20...+70
-20...+70
-20...+70
-20...+60
-20...+60
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
Hours
80 000 / 22 500
80 000 / 17 500
75 000 / 27 500
75 000 / 27 500
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 45 000
70 000 / 45 000
70 000 / 35 000
80 000 / 40 000
80 000 / 40 000
75 000 / 37 500
75 000 / 37 500
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
70 000 / 35 000
Hours
135 000
135 000
127 500
127 500
117 500
117 500
117 500
117 500
117 500
117 500
117 500
135 000
135 000
127 500
127 500
117 500
117 500
117 500
117 500
117 500
117 500
117 500
117 500
117 500
¿
¿
¡
¡
¬
¬
ƒ
ƒ
ƒ
¿
¿
¡
¡
¬
¬
ƒ
ƒ
ƒ
ƒ
¬
Other 48 VDC models on request.
Tin-p
la
ted
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L
W
A ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
2016-01
48
Finger guards
from p. 242
Curve
About the keyboard driver under PXA270
I would like to ask you all, we are using PXA270 platform + wince5.0. The customer gave us a hardware board and asked us to develop a driver. Originally, PXa270 has a keyboard interface, but the custo...
bluemoon Embedded System
Unveiling the ADI chip of the new Meizu PRO 6 Plus
[align=left][font=宋体]The following content is transferred from[/font]ADI[font=宋体]Chinese community:[/font][url=https://ezchina.analog.com/thread/14789]https://ezchina.analog.com/thread/14789[/url][/al...
新人不新 Analog electronics
Signals and Systems (3rd Edition)
Signals and Systems is a national key textbook for general higher education in the "Ninth Five-Year Plan" published by Higher Education Press. The editor is Zheng Junli, professor of the Department of...
arui1999 Download Centre
Can a 100A current flow through a PCB? Tips for setting up high current paths
The current of a normal PCB design will not exceed 10 A, or even 5 A. Especially in home and consumer electronics, the continuous working current on the PCB usually does not exceed 2 A. However, I rec...
btty038 PCB Design
Just saw this, I'll save it for later use of volatile
volatile is equivalent to telling the compiler that the things declared by it are changeable and uncertain, and may be changed by external programs (such as interrupt programs), and prohibiting the co...
yjch2009 Microcontroller MCU
hcnr201 isolation circuit problem
As shown in the picture, the simulation is good, giving a 0-5V sine wave, but after the actual board is powered on, the first op amp becomes hot and the power is also very high. What is the problem?...
关尔郑 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 93  2181  2052  874  1512  2  44  42  18  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号