EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS150AF5/J

Description
Switching Power Supplies 150W 5V 30A
CategoryPower/power management   
File Size535KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

ZWS150AF5/J Overview

Switching Power Supplies 150W 5V 30A

ZWS150AF5/J Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerTDK-LAMBDA
Product CategorySwitching Power Supplies
RoHSDetails
Output Voltage-Channel 15 VDC
Number of Outputs1 Output
Output Power150 W
Open Frame/EnclosedOpen Frame
Input Voltage85 VAC to 265 VAC
Output Current-Channel 130 A
IndustryCommercial
Length2 in
Width1 in
Height0.4 in
ApprovalsEN60950-1, UL60950-1
Factory Pack Quantity1
Unit Weight1 oz
ZWS-AF Series
50W to 150W Single Output Low Cost, Worldwide Use
Features
u
Universal Input (85 - 265VAC)
u
Power factor Corrected
u
Input transient protected
u
2 year warranty
u
High quality design
u
Peak Power capability
Key Market Segments & Applications
Specifications
Model
AC Input Voltage range
DC Input Voltage range
Input Current (Typ) (1)
Inrush Current
Power Factor (1)
Maximum Ripple and Noise
Temperature Coefficient
Overcurrent Protection (4)
Hold Up Time (Typ) (1)
Leakage Current
Remote On / Off
Operating Temperature
Storage Temperature
Humidity (non condensing)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (W x H x D)
Warranty
VAC
VDC
A
A
-
mV
-
-
ms
-
-
-
-
-
-
-
-
-
-
-
-
g
mm
yrs
ZWS75AF
ZWS100AF
ZWS150AF
85-265VAC (47-63Hz)
120-370VDC
0.8/0.4
1.2/0.6
1.4/0.7
2.0/1.0
14/28 25°C Ambient, Cold Start
Meets EN61000-3-2 (0.99/0.95)
3.3 & 5V: 120mV; 12 to 24V: 150mV; 36 & 48V: 200mV
<0.02%/°C
>105% of Peak Current Capability
20ms
0.5mA max 0.1mA (Typ) at 100VAC 0.16mA (Typ) at 230VAC
See installation manual (Not available with /A cover option)
Convection cooling - See table on page 2
0.7m/s air -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C (2)
-30° to +85°C
Operating: 30 - 90% RH, storage 10-95% RH
I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
designed to meet EN55011, EN55022-B, FCC Class B, VCCI-B
designed to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
210
290
380
500
55 x 26 x 195
55 x 32 x 222
62 x 35 x 222
75 x 40 x 222
Two Years
ZWS50AF
Notes:
(1) 100/200VAC
(2) ZWS150AF -10 to 60°C, derate linearly to 70% load from 50°C to 60°C
(3) The peak current draw must not exceed a 10 second duration with a duty cycle of 35%
(4) Constant current limit with automatic recovery. Do not operate in a over-load or shorted output condition for more than 30 seconds.
(5) An overvoltage condition on the output will shut down the power supply. The power supply must be re-set by cycling the AC input.
For New Designs, See ZWSBAF Series
1-800-526-2324 • www.us.tdk-lambda.com/lp/
1
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Desire: Single chip microcomputer stepper motor control
Ask the experts to ask for the C language source program of the stepper motor microcontroller control...
xujun0724 MCU
National Competition Evaluation Criteria
I want to ask, in many questions, it only says adjustable, controllable, but it doesn't say whether it is program controlled or manually adjusted (using potentiometer, manual jumper, etc.), how do the...
表妹酱 Electronics Design Contest
【Supply】Electronic components
Beijing Huaermei Technology Development Co., Ltd. is a professional component distributor and solution provider! For scale applications, we provide data acquisition A/D conversion chips, op amps, micr...
hua111 MCU
2020 Medtec China Exhibition and International Medical Device Design and Manufacturing Technology Exhibition invites you to participate!
The 2020 Medtec China Exhibition and International Medical Device Design and Manufacturing Technology Exhibition will be held at the Shanghai World Expo Exhibition and Convention Center from September...
eric_wang Medical Electronics
If an electronic engineer who studies microcontrollers wants to obtain a nationally recognized certificate, what positions and titles are there?
I want to take a national certificate, but I don't know what to take? How to register for the exam? What books and materials to buy? Can anyone help me?...
爱心 Talking about work
Share the problem of using LM3409
[size=4][b]Question 1: [color=#555555][font="]LM3409, 24V->7V is normal, 24V->7V is abnormal[/font][/color][/b][/size] [color=#555555][font="][size=4] [/size][/font][/color] [size=4][/size] [size=4] [...
qwqwqw2088 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1160  1781  2552  2921  1378  24  36  52  59  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号