Switching Power Supplies 240W 3.3V 5V
CategoryPower/power management   
File Size682KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

ZWX240 Online Shopping

Suppliers Part Number Price MOQ In stock  
ZWX240 - - View Buy Now

ZWX240 Overview

Switching Power Supplies 240W 3.3V 5V

ZWX240 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerTDK-LAMBDA
Product CategorySwitching Power Supplies
RoHSDetails
Output Voltage-Channel 13.3 VDC
Output Voltage-Channel 25 VDC
Number of Outputs1 Output
Output Power240 W
Open Frame/EnclosedOpen Frame
Input Voltage85 VAC to 265 VAC
Output Current-Channel 17 A
Output Current-Channel 26 A
IndustryCommercial
Length8.86 in
Width4.17 in
Height1.42 in
Input Frequency47 Hz to 63 Hz
Load RegulationRegulated
Output Current-Channel 38 A
Output Current-Channel 41.4 A
Output Voltage-Channel 312 V
Factory Pack Quantity1
Unit Weight9.171230 oz
ZWX Series
180W to 300W Industrial ATX Power Supplies
Features
u
90 - 150W convection cooled ratings
u
1U high
u
Power factor corrected
u
Peak power ratings
u
No minimum loading required
Key Market Segments & Applications
Specifications
Model
ZWX180
ZWX240
ZWX300
Input Voltage
V
85-265VAC (47-63Hz)
Input Current (1)(2)
A
1.9 / 1.0
2.6 / 1.3
3.2 / 1.6
Inrush Current (2)
A
14 / 28 Cold start 25°C ambient
Power Factor
-
Meets EN61000-3-2
Leakage Current
mA
< 0.75mA
Temperature Coefficient
°C
<0.02%/°C
Overcurrent Protection (3)
-
>1.05% of forced air current rating (5s delay and manual reset on V1, 2 & 3)
Overvoltage Protection (4)
V
+3.3V: 3.76 - 4.3V, +5V: 5.74 - 7V, +12V: 13.4 - 15.6V
Hold Up Time (Typ) (1)
ms
20ms at 100VAC
Efficiency (1)(2)
%
81 / 84%
Remote On/Off PS_ON
-
High: Unit off, Low: Unit On (enabled). Meets SFX 12V
DC Good PWR_OK
-
High: Power supply is good. Meets SFX12V
Remote Sense
-
+3.3V Only
Output Voltage Setpoint Accuracy
-
±5% (all outputs)
Output Voltage Adjustment
-
None
Line Regulation
mV
3.3V: 20mV, 5V: 48mV, +12V: 48mV, -12V: 20mV, +5Vsb: 20mV
Load Regulation
mV
3.3V: 100mV, 5V: 300mV, +12V: 300mV, -12V: 100mV, +5Vsb: 100mV
Ripple & Noise
mV
3.3V: 120mV, 5V: 150mV, +12V: 150mV, -12V: 120mV, +5Vsb: 120mV
Operating Temperature
-
-10°C to +70°C, derate linearly to 20% load from 50°C to 70°C
Storage Temperature
°C
-30 to +85°C
Humidity (non condensing)
-
Operating: 30 - 90%RH, Non operating: 10 - 95% RH
Cooling
-
Convection or forced air cooled (30CFM, 0.85m3/min)
Withstand Voltage
-
I/P to Grnd 2kVAC (20mA), I/P to O/P 3kVAC (20mA), O/P to Grnd 500VAC (100mA) for 1 min.
Isolation Resistance
-
>100M at 25C & 70%RH, Output to Ground 500VDC
Vibration (non operating)
-
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
Shock (non operating)
-
< 392m/s
2
Safety Agency Approvals
-
UL60950-1, CSA60950-1, EN60950-1, EN50178 (OV II), CE Mark
Conducted & Radiated EMI
-
EN55011/EN55022-B, FCC Class B, VCCI-B
Immunity
-
EN61000-4-2, -3, -4, -5, -6, -8, -11
Weight (Typ)
g
500
650
800
Size (WxHxD)
in
3.7 x 1.42 x 8.27
4.17 x 1.42 x 8.86
4.65 x 1.42 x 9.84
Warranty
yrs
Three Years
(1) With output loading of:
ZWX180: V1=6.5A, V2=6.5A, V3=7.7A, V4=0.2A, V5=1A
ZWX240: V1=8.9A, V2=7.7A, V3=10.2A, V4=0.3A, V5=2A
ZWX300: V1=12A, V2=7A, V3-1=5A, V3-2=9.4A, V4=0.2A, V5=1A
(2) 100/200VAC
(3) Avoid prolonged operation in overload
(4) <5s operation at peak load
1-800-526-2324 • www.us.tdk-lambda.com/lp/
164
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Is it necessary to attend Altium's offline training?
As shown, if anyone has been there, please tell me about it....
sfcsdc PCB Design
Vocational and technical college group (collection of masters)
[i=s]This post was last edited by paulhyde on 2014-9-15 08:58[/i]Automatic resistance tester and waveform acquisition, storage and playback system should be very common topics.The waveform acquisition...
levelgod Electronics Design Contest
Post a post to earn points..
...
87136226 Embedded System
Ask for help ~ evc edit box text operation problem
There are two edit boxes IDC_EDT1 CString m_edt1 and IDC_EDT2 CString m_edt2. I want to subtract the values in these two edit boxes (now there are two numbers in them) and put them into the edit box I...
arkin Embedded System
Infrared thermometer development - interested friends please contact me
-50℃~110℃ (±.5℉) Infrared distance 2 meters Pen-shaped. Button battery 2-digit display...
品位人生 MCU
Ground Design Tips
[:)][:)][:)]   For analog circuits, the design of the ground wire is a critical link. Many circuits such as digital meters, AD/DA interface boards, etc. have a distinction between digital ground and a...
fighting Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1664  818  1084  2529  2651  34  17  22  51  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号