EEWORLDEEWORLDEEWORLD

Part Number

Search

HWS150A-24/A

Description
Switching Power Supplies 24V 6.5A 156W
CategoryPower/power management    The power supply circuit   
File Size482KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

HWS150A-24/A Overview

Switching Power Supplies 24V 6.5A 156W

HWS150A-24/A Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTDK-LAMBDA
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresIT ALSO OPERATES DC VOLTAGE 120 TO 370
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Maximum input voltage265 V
Minimum input voltage85 V
Nominal input voltage100 V
JESD-30 codeR-XXMA-X
Number of functions1
Output times1
Maximum operating temperature50 °C
Minimum operating temperature-10 °C
Maximum output voltage28.8 V
Minimum output voltage19.2 V
Nominal output voltage24 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output150 W
Fine-tuning/adjustable outputYES
HWS15A-150A/A Series
50-150W Single Output Industrial Power Supplies
Features
Limited Lifetime Warranty
UL508 approved
SEMI F47 Compliant (high line AC)
Universal Input (85 - 265VAC)
Higher Efficiency Than HWS series
Key Market Segments & Applications
Specifications
Model
Input Voltage Range
Input Current (Typ) (1)
Inrush Current (1)
-
A
A
-
Power Factor (1)
-
Temperature Coefficient
%/°C
Overcurrent Protection
%
Overvoltage Protection
V
Hold Up Time (Typ)
ms
Leakage Current (max)
mA
Remote Sense
-
Indicator
-
Operating Temperature (with cover) °C
Storage Temperature
°C
Humidity (non condensing)
%RH
Cooling
-
Withstand Voltage
VAC
Isolation Resistance
M Ohms
Vibration (non operating)
-
Shock
m/s
2
Safety Agency Approvals
-
Line Dip
-
Conducted & Radiated EMI
-
Immunity
-
Weight (Typ)
g
Size (WxHxD) (with cover)
Inches
mm
MTBF - Telcordia SR-332 issue 3**
Hours
Warranty
-
HWS15A/A
HWS30A/A
HWS50A/A
HWS100A/A
HWS150A/A
85 - 265VAC (47 - 63Hz) or 120 - 370VDC* (Withstands 300VAC for 5s)
0.35 / 0.2
0.65 / 0.4
0.65 / 0.35
1.3 / 0.65
1.9 / 0.95
14 / 28
Meets EN61000-3-2
-
-
0.97/0.91
0.98/0.93
0.98/0.93
<0.02%/°C
>105%
Yes
20
>0.5mA (Typ 0.2mA at 100VAC, 0.4mA at 230VAC)
No
Yes
Green LED = ON
-10°C to +70°C, derate linearly to 20% load from 50°C to 70°C (2)
-30 to +85°C
Operating: 30 - 90%RH, Non operating 10 - 95%RH
Convection
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
Complies with SEMI F47 (200VAC line only)
EN55011 / EN55022-B, FCC-B, VCCI-B
IEC61000-4-2, -3, -4, -5, -6, -8, -11; IEC61000-6-2
190
240
300
470
520
1.24x3.23x3.15 1.24x3.23x3.74 1.24x3.23x4.72
1.3x3.23x6.3
1.65x3.23x6.3
31.5x82x80
31.5x82x95
31.5x82x120
33x82x160
42x82x160
12,116,851
8,169,868
3,726,622
2,963,512
2,676,081
Limited lifetime warranty (See website for terms & conditions)
* Safety certified for AC input only ** 24V output model, 25°C ambiient, full load, 230VAC input
(1) 100/200VAC
(2) HWS15A/A derates linearly to 50% load from 50 to 70°C
1-800-526-2324 • www.us.tdk-lambda.com/lp/
14
Disclaimer: us.tdk-lambda.com/lp/legal.htm
STM32F072 program for serial port 12864
[i=s] This post was last edited by wawaw on 2015-1-19 19:52 [/i] The LCD is 5V...
wawaw stm32/stm8
Why doesn't his AD conversion need to be multiplied by the resolution?
Program of Puzhong Technology: temp = Read_AD_Data(0x94); //Initialize AD, read the value of AIN0 (001) channel. Shouldn't the AD value reading be vin=read_ad()*500.0/1024; similar to this? The chip u...
1535225922 51mcu
How to operate an oscilloscope without an instruction manual
There are many types of oscilloscopes, and a large proportion of them do not have instruction manuals, which is very inconvenient for beginners who use oscilloscopes for the first time. Based on pract...
songbo Test/Measurement
Please send me a cracker for DSPbuilder9.1sp2
I have not found the cracker for DSPbuilder9.1sp2. Please help me. Thanks....
cherishzxg FPGA/CPLD
PCB Export – Ansoft Intermediate File
PCB Export – Ansoft Intermediate FileFor more details, please see the PDF file:...
520spxiong PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1550  1144  1078  2918  697  32  24  22  59  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号