EEWORLDEEWORLDEEWORLD

Part Number

Search

88974152

Description
Controllers M3CUSTOM XB26
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size124KB,5 Pages
ManufacturerCrouzet
Environmental Compliance
Download Datasheet Parametric View All

88974152 Online Shopping

Suppliers Part Number Price MOQ In stock  
88974152 - - View Buy Now

88974152 Overview

Controllers M3CUSTOM XB26

88974152 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerCrouzet
Product CategoryControllers
RoHSDetails
Analog / DigitalDigital
TypeExpandable Range
Display TypeLCD Display
Operating Supply Voltage24 VDC
MountingDIN Rail
Size124.6 mm x 90 mm x 57.5 mm
FeaturesMemory back-up using EEPROM or battery
Number of Outputs10
Output TypeRelay
Number of Inputs16
Factory Pack Quantity1
02/11/2015
www.crouzet.com
Smart "Expandable" range without display XB26 Smart Part number 88974152
Efficient and economical version, without display or keys setting
Allow the use of the entire library of specific functions blocs of the software workshop
Extended temperature range (-30 °C →+70 °C) 
Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters)
Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions
Part numbers
Type
88974152
XB26 Smart
Inputs
16 digital (including 6 analogue)
Outputs
10 solid state 0.5 A (including 4 PWM)
Supply
24 V DC
Specifications
General environment characteristics for CB, CD, XD, XB, XR and XE product types
Certifications
Conformity to standards (with the low voltage directive
and EMC directive)
CE, UL, CSA, GL
IEC/EN 61131-2 (Open equipment)
IEC/EN 61131-2 (Zone B)
IEC/EN 61000-6-2,
IEC/EN 61000-6-3 (*)
IEC/EN 61000-6-4
(*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Not included
In accordance with IEC/EN 60529 :
IP40 on front panel
IP20 on terminal block
3 in accordance with IEC/EN 60664-1
Degree : 2 in accordance with IEC/EN 61131-2
Operation : 2000 m
Transport : 3048 m
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Immunity to ESD
IEC/EN 61000-4-2, level 3
Immunity to radiated electrostatic fields
IEC/EN 61000-4-3
Immunity to fast transients (burst immunity)
IEC/EN 61000-4-4, level 3
Immunity to shock waves
IEC/EN 61000-4-5
Radio frequency in common mode
IEC/EN 61000-4-6, level 3
Voltage dips and breaks (AC)
IEC/EN 61000-4-11
Immunity to damped oscillatory waves
IEC/EN 61000-4-12
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1
(*) Except configuration (88 970 1.1 or 88 970 1.2) +
(88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
-20 →+70 °C 
except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure)
in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
-40 →+80 °C in accordance with IEC/EN 60068-2-1 and
IEC/EN 60068-2-2
95 % max. (no condensation or dripping water) in accordance with
IEC/EN 60068-2-30
On symmetrical DIN rail, 35 x 7.5 mm and 35 x 15 mm, or on panel (2 x Ø 4 mm)
Flexible wire with ferrule =
1 conductor : 0.25 to 2.5 mm
2
(AWG 24...AWG 14)
2 conductors 0.25 to 0.75 mm
2
(AWG 24...AWG 18)
Semi-rigid wire =
1 conductor : 0.2 to 2.5 mm
2
(AWG 25...AWG 14)
Rigid wire =
1 conductor : 0.2 to 2.5 mm
2
(AWG 25...AWG 14)
2 conductors 0.2 to 1.5 mm
2
(AWG 25...AWG 16)
Tightening torque =
0.5 N.m (4.5 lb-in) (tighten using screwdriver diam. 3.5 mm)
Also valid for spring cage connectors (ref 88 970 313 and 88 970 317 for the RBT range)
Earthing
Protection rating
Overvoltage category
Pollution
Max operating Altitude
Mechanical resistance
Resistance to electrostatic discharge
Resistance to HF interference
Conducted and radiated emissions
Operating temperature
Storage temperature
Relative humidity
Mounting
Screw terminals connection capacity
General characteristics
Operating temperature
-30 →+70 °C (DC)  ; -20 →+70 °C (AC)
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
Passthru network card data acquisition problem
Hello everyone, I have a question! I installed two network cards on a machine and installed the passthru program I rewrote. I know that passthru will automatically bind to the two network cards. The p...
qw12345 Embedded System
Why choose stm32 and allegro instead of 51 and protel?
This is for the future consideration of the participants. 51 is not worth the money. Those who can find 1500 are just paying a lot of money. Moreover, they must do both software and hardware. STM32 is...
wangkj stm32/stm8
【MXCHIP MX1081】My WiFi controlled LED
[media=x,800,600]http://v.youku.com/v_show/id_XODQzODYxOTI4.html[/media]...
90houyidai RF/Wirelessly
Anyone has a book on how to use ModeSim? Please share it with me.
I haven't seen Altera's FPGA for a long time. I wanted to simulate it recently, but found that the new version can only be simulated using ModeSim. Do you have an e-book on how to use it? Please share...
jixfjixf FPGA/CPLD
synplify calls IP core
Can I use synplify to call Altera's IP core? If so, how can I do it?...
火箭_1991 FPGA/CPLD
Help: Atmel 89c51ed2 microcontroller needs to click start application in FLIP to run
As the title says. After the program is copied in, it cannot run. Only by clicking start application in the downloaded software FLIP can the program run. Note: Even if you copy in the simplest program...
cl640400 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1427  2506  1272  2869  1093  29  51  26  58  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号