DP4R60D20

Description
Solid State Relays - Industrial Mount PM DC H Bridge 48V 20A 15V CNT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size1MB,7 Pages
ManufacturerSensata
Environmental Compliance
Download Datasheet Parametric View All

DP4R60D20 Online Shopping

Suppliers Part Number Price MOQ In stock  
DP4R60D20 - - View Buy Now

DP4R60D20 Overview

Solid State Relays - Industrial Mount PM DC H Bridge 48V 20A 15V CNT

DP4R60D20 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerSensata
Product CategorySolid State Relays - Industrial Mount
RoHSDetails
Control Voltage Range4.5 VDC to 15 VDC
Mounting StylePanel
Relay Contact Form3 Form A (3PST-NO)
Load Voltage Rating1 VDC to 48 VDC
Load Current Rating20 A
Input Current16 mA to 20 mA
Output TypeSCR
Contact Form3PST (3 Form A)
ProductSSR - Solid State Relays
Termination StyleScrew
TypeHeavy Duty
Factory Pack Quantity5
Unit Weight10.879991 oz
DataSheet
DP Series
DC Reversing Solid State Contactor
Ratings of 20, 40 & 60 Amps
Load voltage ratings of 1-48 VDC
Optional Soft Start w/Brake, Soft Start/Soft Stop no Brake
LED input status indicator. Green (Forward), Yellow (Reverse)
DC control
cULus Recognized, IEC Rated, CE & RoHS Compliant
Control Relays
PRODUCT SELECTION
Control Voltage
4-15 VDC
18-32 VDC
20 A
DP4R60D20
DP4R60E20
40 A
DP4R60D40
DP4R60E40
60 A
DP4R60D60
DP4R60E60
AVAILABLE OPTIONS
Start Mode
Blank:
Start
SA:
Soft Start/Ramp
Up, 0.2 sec
SB:
Soft Start/Ramp
Up, 0.5 sec
SC:
Soft Start/Ramp
Up, 1 sec
Stop Mode
Blank:
Stop Mode matches Start Mode
B2:
Dynamic Brake, 0.2 sec
B5:
Dynamic Brake, 0.5 sec
B8:
Dynamic Brake, 0.2 sec
B:
Dynamic Brake, Continuous
Series
Control Voltage:
D:
4.5-15 VDC
E:
18-32 VDC
DP
4R
Function
4R:
4 Channel DC
Reversing
SB
60
D
40
B
H
Thermal Pad
Blank:
Not Included
H:
Included
Rated Operating Voltage Operating Current
60:
1-48 VDC
20:
20 Amps
40:
40 Amps
60:
60 Amps
Required for valid part number
For options only and not required for valid part number
OUTPUT SPECIFICATIONS
(1)
Description
Operating Voltage [VDC]
UL 508 Resistive Load, IEC 60947-4-1 DC-1 [Adc]
UL 508 Motor Controller, IEC 60947-4-1 DC-3 [FLA]
Minimum Load Current [A]
Maximum Surge Current (10ms) [Adc]
Maximum Off-State Leakage Current @ Rated Voltage [µA]
Maximum On-State Voltage Drop @ Rated Current [Vdc]
Combined Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum On-State Resistance, per switch, (RDS-ON) [Ohms]
Total Power Dissipation per module, 2 switches conducting, Tj=100° C [Watts]
Internal PWM For Soft Start/Stop Ve rsions [Duty Cycle 10-100%] [Hz]
Output Terminal Screw size
Screw Torque Range [in lbs/Nm]
Maximum Wire Size
Weight (typical)
20 A
1-48
20
13
0.10
80
20
0.28
0.40
0.014
20
200
10-32 Combo Head
15-20 / 1.7-2.3
10 AWG
10.9 oz (310g)
40 A
1-48
40
14
0.10
140
20
0.28
0.20
0.007
40
200
1/4-20 Hex
20-25 / 2.3-2.8
8 AWG
12.2 oz (345g)
60 A
1-48
60
15
0.10
240
20
0.30
0.13
0.005
60
200
1/4-20 Hex
20-25 / 2.3-2.8
6 AWG
12.2 oz (345g)
FDE-07-01 REV. A
Do not forget to visit us at:
www.crydom.com
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.
What is the unity gain bandwidth of LF357?
Can anyone tell me what the unity gain bandwidth of LF357 can achieve? Thank you very much!...
小巷 Analog electronics
Professor Zhang Yueping: 5G brings about the trend of Antenna in Package (AiP) technology
In the 5G and post-5G mobile world, packaged antenna (AiP) will be everywhere. It will be embedded in your mobile phone as shown in Figure 1, providing you with a new and extraordinary high-quality us...
ohahaha RF/Wirelessly
The difference between ds18b20 and ds1820
I only have the ds1820 sensor and I don't know what the difference is between this sensor and the ds18b20 when writing programs. I used the ds18b20 program I had adjusted before, but it doesn't displa...
melodyooo MCU
[Xiaomeige SOPC Learning Notes] Several settings that need to be paid attention to in the software after switching the main memory of NIOS II CPU
[b][align=center][b][size=5]Sometimes, we may face such a situation:[/color][/size] [size=4][color=#000]1. We create a SOPC system and set the reset address and exception address of NIOS II to SRAM in...
芯航线跑堂 FPGA/CPLD
AECQ Op Amp Cost Issues
Recently, something like this happened to me. The quad op amps LM2904 and LM2902 that we often use are very mature in technology, have a large output, and are relatively cheap. In the design, the volt...
yulzhu Analog electronics
Is it necessary to use a synchronization signal to generate three-phase PWM by 28335?
I still don't understand why the synchronization signal is only needed when the epwm of different DSPs work together. The epwm of the same DSP all use the same system clock. They should be synchronize...
jonny0811 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 980  2020  376  460  909  20  41  8  10  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号