Packard Electric Metri-Pack 150 Series, M12 - 4 Pole *
G1/4A DIN 3852-E, G1/4A DIN 3852-A *
304 Stainless Steel (1.4301)
4 - 20 mA, 0.5 - 4.5 VDC, 0 - 5 VDC, 0 - 10 VDC
Attributes
Hermetically Sealed
Rugged & Durable
Compact & Light-weight
Resistant to Chemical Attack
Superior Long-Term Stability & Repeatability
Outstanding Shock & Vibration Performance
Typical Applications
Compressors
Hydraulic Systems
Agricultural Equipment
Construction Equipment
Heat Pumps
Wind Energy
HVAC Systems
Chemical Industry
Description
The PTE5000 utilizes Kavlico’s thin film strain gauge sensing technology, incorporating an hermetically
sealed design with no internal sealing required. Designed for harsh environments, a rugged 304 stainless
steel housing surrounds the PTE5000 transducer.
The PTE5000’s small, compact design as well as its low overall weight makes it ideal
for applications with spacing and weight limitations. This easy-to-use sensor is media
resistant, which allows it to be used for a broad range of liquid and gaseous media. It
can be used at high operating temperatures and has internal temperature compensation.
Highly reliable, the PTE5000 provides accurate, high pressure measurements every time.
www.kavlico.com
Technical Specifications
Pressure Ranges
from 0 to …
Proof pressure
Burst pressure
bar (gage)
bar (gage)
bar (gage)
6
12
60
10
20
100
16
32
160
25
50
200
40
80
320
60
120
480
100
200
600
160
320
960
250
500
1000
400
800
1600
600
1200
2400
Physical
Operating Life Cycle
Vibration Resistance
Shock Resistance
Drop Test
Weight
Ingress Protection
Medium Temperature
Storage Temperature
Media
*4
min. 10 million full pressure cycles over the full range
IEC 60068-2-64 (RANDOM) 20 PSD
25 g minimum according to DIN EN 60068-2-27
1 meter drop on concrete as per SAE J1455 / DIN EN 60068-2-3-1
≤
50 grams (without mating connector)
IP 65 or IP67 - depending on electrical connector
-30°C to + 120°C (others on request)
-30°C to + 100°C (dep. on electrical connector & external seal ring capability)
*4
All class II fluids and gases compatible with stainless steel 304 (1.4301)
Environmental Temperature
-30°C to + 100°C (dep. on electrical connector & external seal ring capability)
*4
For more details see How to Order
Performance
Accuracy
*1
Non-linearity
*2
Non-repeatability
1-year stability
Temp. Coefficients - Zero
Temp. Coefficients - Span
*1
*2
≤
0.5 % of span
*3
0.2 % of span
*3
0.1 % of span
*3
0.2 % of span
*3
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with pressure port down.
BFSL according to IEC 61298-2 reference conditions to EN 61298-1
Others on request
*3
www.kavlico.com
Data Sheet PTE5000
2
Electrical
0.5…4.5 VDC
ratiometric
5 VDC ± 5%
≤
25 mW
min. 6 VDC
Yes
*5
500 VDC
Yes
*6
Output Signal
Operating Supply Signal
Power Consumption
Overvoltage Protection
Short-circuit Proofness
Insulation Voltage
Load
Response Time
*5
4…20 mA
8-30 VDC
≤
600 mW
min. 33 VDC
not applicable
500 VDC
0…5 VDC
8-30 VDC
≤
600 mW
min. 33 VDC
Yes
*5
500 VDC
Yes
*6
≥
4.7 kΩ
0…10 VDC
14-30 VDC
≤
600 mW
min. 33 VDC
Yes
*5
500 VDC
Yes
*6
≥
4.7 kΩ
Reverse Polarity Protection
Yes
*6
≤
(Vsup-8 VDC)/(0.02 A) [Ω]
≥
4.7 kΩ
≤
5 ms max. to 63% of full scale pressure with step change on input
for min. 3 intervals at 5 minutes each
for min. 10 seconds on assigned pins
*6
Approvals & Certificates
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EEC, EN 61 326 Emission (Group 1, Class B)
and Immunity (industrial locations), EMI, ESD protected
Standard(s) for Safety: Electrical Equipment for Measurement, Control and
Laboratory Use - UL 61010-1
2011/65/EU ROHS Directive
CE Compliance
UL
ROHS
www.kavlico.com
Data Sheet PTE5000
3
Dimensions
Pressure Sensor with Electrical Connection
Dimensions in mm [Inch]
M12 Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
...
...
...
...
Pin 3
lout
Vout
Vout
Vout
Pin 4
...
GND
GND
GND
18 mm Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
lout
Vout
Vout
Vout
Pin 3
...
GND
GND
GND
Pin 4
...
...
...
...
Packard (metri-pack 150) Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
lout
GND
GND
GND
Pin 2
Vsup
Vsup
Vsup
Vsup
Pin 3
...
Vout
Vout
Vout
9.4 mm Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
lout
Vout
Vout
Vout
Pin 3
...
GND
GND
GND
Pin 4
...
...
...
...
www.kavlico.com
Data Sheet PTE5000
4
Pressure Connections and Recommended Installation Torque
Have you ever thought about doing something big and meaningful but worried that it would be hard to do? Then, when you finally get the courage to do it, you look back and are surprised at how easy it ...
[size=3]Previous reason: Two administrators discussed the download center function and wanted to add a user record function to download the resource, so as to facilitate communication between netizens...
http://shop60008893.taobao.com. All friends in this forum will enjoy discounts. Introduction to RF1020 module: Module features: (1) Frequency range is 402 MHz -470MHz (2) High sensitivity (up to -118d...
Using DAC0832 to generate a sine waveform generator, the waveform cannot be designed. I don't know what is wrong. My circuit diagramProgram #include
#include
#define uchar unsigned char #define uint u...
After AD conversion, we get 4 groups of word type AD values, which are stored in 4 arrays a0[8], a1[8], a2[8], and a3[8] respectively. Now we want to get the average value of a0[8], a1[8], a2[8], and ...
Emergency hand-held lamps powered by 6V maintenance-free batteries are widely used in rural areas. The charger used is a transformer step-down and single diode half-wave rectifier, and the charging...[Details]
Microchip's PIC18F46J50 is a low-power, high-performance 8-bit USB microcontroller (MCU) using nanoWatt XLP technology. The current in deep sleep mode can be as low as 13nA, the operating voltage i...[Details]
No matter which processor you are learning, the first thing you need to understand is the registers and working mode of the processor.
ARM has 37 registers, including 31 general registers and ...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
Two simple circuits are implemented to drive two LEDs from a battery powered microprocessor.
This design is based on a circuit that uses three resistors and a microprocessor I/O pin as an input h...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
Microcalorimetry
is used to determine energy relationships. Microcalorimetry techniques are often required when performing calorimetric experiments with small sample sizes or slow heating rat...[Details]
1. Introduction to CIF Board
Fieldbus integration based on PC system
Whether it is a master or a slave, fieldbus has won unanimous praise in the field of PC-based automation. For more...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
Printed circuit boards ( PCBs
)
are used in most electrical products
. If a PCB has low
insulation resistance
(IR), the performance of the circuits on the PCB will be greatly reduced...[Details]
With the rapid development of cities and the improvement of citizens' living standards, the number of various vehicles in cities is growing, and the demand for parking spaces in major commercial an...[Details]
store
To prevent moisture, LEDs should be stored in a dry and ventilated environment with a storage temperature of -40°C to +100°C and a relative humidity below 85%.
The LED should be use...[Details]
Electric bicycles have long been a means of transportation for lower-income groups due to their affordability. The largest concentrated expense in the use of electric vehicles is the cost of replac...[Details]
Portable power applications are broad and varied. Products range from wireless sensor nodes with average power consumption of only a few microwatts to in-vehicle medical or data acquisition systems...[Details]
0 Introduction
In the design and construction of communication systems,
communication power supply
is called the heart of the communication system. The power supply system will dire...[Details]