Packard Electric Metri-Pack 150 Series, M12 - 4 Pole *
G1/4A DIN 3852-E, G1/4A DIN 3852-A *
304 Stainless Steel (1.4301)
4 - 20 mA, 0.5 - 4.5 VDC, 0 - 5 VDC, 0 - 10 VDC
Attributes
Hermetically Sealed
Rugged & Durable
Compact & Light-weight
Resistant to Chemical Attack
Superior Long-Term Stability & Repeatability
Outstanding Shock & Vibration Performance
Typical Applications
Compressors
Hydraulic Systems
Agricultural Equipment
Construction Equipment
Heat Pumps
Wind Energy
HVAC Systems
Chemical Industry
Description
The PTE5000 utilizes Kavlico’s thin film strain gauge sensing technology, incorporating an hermetically
sealed design with no internal sealing required. Designed for harsh environments, a rugged 304 stainless
steel housing surrounds the PTE5000 transducer.
The PTE5000’s small, compact design as well as its low overall weight makes it ideal
for applications with spacing and weight limitations. This easy-to-use sensor is media
resistant, which allows it to be used for a broad range of liquid and gaseous media. It
can be used at high operating temperatures and has internal temperature compensation.
Highly reliable, the PTE5000 provides accurate, high pressure measurements every time.
www.kavlico.com
Technical Specifications
Pressure Ranges
from 0 to …
Proof pressure
Burst pressure
bar (gage)
bar (gage)
bar (gage)
6
12
60
10
20
100
16
32
160
25
50
200
40
80
320
60
120
480
100
200
600
160
320
960
250
500
1000
400
800
1600
600
1200
2400
Physical
Operating Life Cycle
Vibration Resistance
Shock Resistance
Drop Test
Weight
Ingress Protection
Medium Temperature
Storage Temperature
Media
*4
min. 10 million full pressure cycles over the full range
IEC 60068-2-64 (RANDOM) 20 PSD
25 g minimum according to DIN EN 60068-2-27
1 meter drop on concrete as per SAE J1455 / DIN EN 60068-2-3-1
≤
50 grams (without mating connector)
IP 65 or IP67 - depending on electrical connector
-30°C to + 120°C (others on request)
-30°C to + 100°C (dep. on electrical connector & external seal ring capability)
*4
All class II fluids and gases compatible with stainless steel 304 (1.4301)
Environmental Temperature
-30°C to + 100°C (dep. on electrical connector & external seal ring capability)
*4
For more details see How to Order
Performance
Accuracy
*1
Non-linearity
*2
Non-repeatability
1-year stability
Temp. Coefficients - Zero
Temp. Coefficients - Span
*1
*2
≤
0.5 % of span
*3
0.2 % of span
*3
0.1 % of span
*3
0.2 % of span
*3
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with pressure port down.
BFSL according to IEC 61298-2 reference conditions to EN 61298-1
Others on request
*3
www.kavlico.com
Data Sheet PTE5000
2
Electrical
0.5…4.5 VDC
ratiometric
5 VDC ± 5%
≤
25 mW
min. 6 VDC
Yes
*5
500 VDC
Yes
*6
Output Signal
Operating Supply Signal
Power Consumption
Overvoltage Protection
Short-circuit Proofness
Insulation Voltage
Load
Response Time
*5
4…20 mA
8-30 VDC
≤
600 mW
min. 33 VDC
not applicable
500 VDC
0…5 VDC
8-30 VDC
≤
600 mW
min. 33 VDC
Yes
*5
500 VDC
Yes
*6
≥
4.7 kΩ
0…10 VDC
14-30 VDC
≤
600 mW
min. 33 VDC
Yes
*5
500 VDC
Yes
*6
≥
4.7 kΩ
Reverse Polarity Protection
Yes
*6
≤
(Vsup-8 VDC)/(0.02 A) [Ω]
≥
4.7 kΩ
≤
5 ms max. to 63% of full scale pressure with step change on input
for min. 3 intervals at 5 minutes each
for min. 10 seconds on assigned pins
*6
Approvals & Certificates
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EEC, EN 61 326 Emission (Group 1, Class B)
and Immunity (industrial locations), EMI, ESD protected
Standard(s) for Safety: Electrical Equipment for Measurement, Control and
Laboratory Use - UL 61010-1
2011/65/EU ROHS Directive
CE Compliance
UL
ROHS
www.kavlico.com
Data Sheet PTE5000
3
Dimensions
Pressure Sensor with Electrical Connection
Dimensions in mm [Inch]
M12 Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
...
...
...
...
Pin 3
lout
Vout
Vout
Vout
Pin 4
...
GND
GND
GND
18 mm Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
lout
Vout
Vout
Vout
Pin 3
...
GND
GND
GND
Pin 4
...
...
...
...
Packard (metri-pack 150) Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
lout
GND
GND
GND
Pin 2
Vsup
Vsup
Vsup
Vsup
Pin 3
...
Vout
Vout
Vout
9.4 mm Pin Call Outs
Output
4-20 mA
0.5-4.5 VDC ratiometric
0-5 VDC
0-10 VDC
Pin 1
Vsup
Vsup
Vsup
Vsup
Pin 2
lout
Vout
Vout
Vout
Pin 3
...
GND
GND
GND
Pin 4
...
...
...
...
www.kavlico.com
Data Sheet PTE5000
4
Pressure Connections and Recommended Installation Torque
When sampling the ADC module of a 3.3v dsp, what is the bias voltage used for the AC voltage sampling signal? I want to use 1.5v, but I can't find any device that generates a 1.5v reference voltage. M...
When tracking the wince serial port driver, a cxx0017 error appears in the watch window. Some variables cannot be found, and the prompt "symbol "pSerialHead" not found, and several other variables can...
I have been working on the Wince5.0 SD card driver recently. After half a month of tinkering, the driver is ready. There are no problems with writing and reading files. I originally planned to end the...
Dongle and Cloud Authorization
In China, encryption locks are still the dominant software protection method. In the past 30 years, computer hardware has been updated for countless generations, and sof...
The C8051F microcontroller that our company represents can be debugged, simulated and downloaded online through JTAG. In terms of debugging, it has good encryption! Contact: 021-61202632 Ms. Yue...
Assume that data is read from 8-bit AD (if it is a higher-bit AD, the data type can be defined as int), the subroutine is get_ad();
1. Limited secondary filtering
/* A value can be adjust...[Details]
Microchip's PIC18F46J50 is a low-power, high-performance 8-bit USB microcontroller (MCU) using nanoWatt XLP technology. The current in deep sleep mode can be as low as 13nA, the operating voltage i...[Details]
Floating-point digital signal processing has become a constant requirement for precision technology, often in applications requiring high accuracy in areas such as aviation, industrial machinery, a...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
1 Introduction
Solar street lights are mainly composed of four parts: solar photovoltaic cell components, batteries, charge and discharge controllers, and lighting fixtures. The bo...[Details]
Two simple circuits are implemented to drive two LEDs from a battery powered microprocessor.
This design is based on a circuit that uses three resistors and a microprocessor I/O pin as an input h...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
Microcalorimetry
is used to determine energy relationships. Microcalorimetry techniques are often required when performing calorimetric experiments with small sample sizes or slow heating rat...[Details]
1. With the development of modern industry and the continuous improvement of automation, some medium and large control systems have been greatly facilitated, which not only makes control easier, bu...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
The potentiometer is an adjustable electronic component. The main functions of the potentiometer in the circuit are as follows:
1. Used as a voltage divider
A potentiometer is a continuou...[Details]
In recent years, with the rapid development of the information industry, dot matrix LED display screens have been widely used in various advertising and information display systems such as the fina...[Details]
Overview
In spectral measurement, photomultiplier tubes (PMT) and charge-coupled devices (CCD) are often used as photoelectric converters. PMT is used in slow-changing, high-precision spectral...[Details]
Investment in
the
medical device
industry has been on the rise in recent years. In the past two years, venture capital for medical devices has almost doubled, reaching $4 billion in 2007. Fr...[Details]
Today, the value of electronic components in cars accounts for 15-20% of the total vehicle. In the future, this proportion may be as high as 30-40% as more safety electronics, fuel consumption and ...[Details]