DC - 3 WIRE-EXTENDED SENSING DISTANCE
Brass, Nickel Plated (BN), Cylindrical,
Threaded, 10-30V DC, 200mA,
LED for Output Energized
•
IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
•
Short Circuit Protection
•
Overload Protection
•
Reverse Polarity Protection
•
Wire Break Resistance
•
Transient Voltage Protection
•
Temperature Range: -25 to 70°C (-13 to 158°F)
PNP
NPN
Sensing Distance
Cable or Connector Style Cat. No.
Normally Open
Normally Open
Ripple Voltage
Voltage Range
AIS12F04AN024-2M
≤10%
10-30V
≤15mA
200 mA
≤2.5V
≤1µA
1000 Hz
≤0.4mm
≤±8µm/K
≤0.2mm
AIS12F04AP024-2M
Cable
M12 Flush Mount
4mm (.16 in.)
AIS12F04AN024-Q65
AIS12F04AP024-Q65
65
No Load Current
Max. Load Current
Voltage Drop Across Sensor
Max. Leakage Currrent
Switching Frequency
Hysterisis
Temperature Drift
Repeatability
Fixed Cable
PVC 2m (6ft. 6in.). For other cable
lengths and/or PUR cable, please
consult Altech. Supplied with brass,
nickel plated locknuts.
M12x1
A/F 17
40
60
80
65 Style Connector
4-pin, Micro style, 12mm (.47 in.).
Supplied with brass, nickel plated
locknuts.
M12x1
4
A/F 17
LED
M12x1
40
70
Not e: Sen s o r di men s i on s in m m.
12
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
ø9
ø4
LED
ø11
4
Metric/in. Conversion Table
1.5 mm
2.0 mm
4.0 mm
5.0 mm
6.0 mm
8.0 mm
10.0 mm
12.0 mm
15.0 mm
18.0 mm
=
=
=
=
=
=
=
=
=
=
.06 in.
.08 in.
.16 in
.20 in.
.23 in.
.31 in.
.39 in.
.47 in.
.59 in.
.70 in.
23.0 mm
28.0 mm
30.0 mm
32.0 mm
34.0 mm
40.0 mm
50.0 mm
51.0 mm
60.0 mm
80.0 mm
=
=
=
=
=
=
=
=
=
=
.08 in.
1.10 in
1.18 in.
1.26 in.
1.34 in.
1.57 in.
1.97 in.
2.01 in.
2.36 in.
3.12 in.
This table converts
millimeters to inches
in reference to the
illustrations included
on these pages.
If you do not see a
coverted dimension,
multiply mm by
0.03937 to convert to
inches.
AIS18F08AN024-2M
≤10%
10-30V
≤15
mA
200 mA
≤2.5V
≤1
µA
500 Hz
≤0.8mm
≤±12µm/K
≤0.4mm
AIS18F08AP024-2M
Cable
M18 Flush Mount
8mm (.31 in.)
AIS18F08AN024-Q65
AIS18F08AP024-Q65
65
Note: Wire colors are applicable on cables
purchased from Altech
Fixed Cable
Wiring Diagrams
PNP
BR
+
BK
Fixed Cable
NPN
BR
+
BK
•
Normally Open
•
BL
–
LOAD
LOAD
Normally Open
65 Connector
1
BL
–
65 Connector
1
4
BK
3
BR +
LOAD
2
Normally Open
•
4
BR
BL
–
2
Normally Open
3 BL
BK
•
LOAD
–
+
M8x1
60
80
100
4
M18x1
A/F 24
LED
M12x1
50
70
80
Not e: Sen s o r di men s i on s in m m.
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
ø11
ø5
LED
ø14
4
A/F 24
13