Operating/Storage: 35% to 95% (with no condensation)
±10%
max. of sensing distance at 23°C in the temperature range of
−25
to 70°C
±2.5%
max. of sensing distance at rated voltage in the rated voltage
±15%
range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
2
3 times each in X, Y, and Z directions
IEC 60529 IP67, in-house standards: oil-resistant
*2
Pre-wired Models (Standard cable length: 2 m)
Approx. 80 g
Heat-resistant ABS
Instruction manual
*1. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.
2
TL-W
DC 3-Wire Models
Item
Set distance
Differential travel
Detectable object
Standard sensing
object
Response
frequency
Model
TL-W1R5MC1
TL-W1R5MB1
1.5 mm
±10%
0 to 1.2 mm
TL-W3MC@
TL-W3MB@
3 mm
±10%
0 to 2.4 mm
TL-W5MC@
TL-W5MB@
5 mm
±10%
0 to 4 mm
TL-W5E1, TL-W5E2
TL-W5F1, TL-W5F2
TL-W20ME1
TL-W20ME2
20 mm
±10%
0 to 16 mm
1% to 15% of sensing
distance
Iron, 18
×
18
×
1 mm
500 Hz min.
300 Hz min.
12 to 24 VDC (10 to 30
VDC), ripple (p-p): 20%
max.
15 mA max.
at 24 VDC (no-load)
Iron, 50
×
50
×
1 mm
40 Hz min.
12 to 24 VDC (10 to 30
VDC), ripple (p-p): 10%
max.
8 mA at 12 VDC,
15 mA at 24 VDC
Sensing distance
10% max. of sensing distance
Iron,
8
×
8
×
1 mm
1 kHz min.
Iron,
12
×
12
×
1 mm
600 Hz min.
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data
on page 5.)
Power supply volt-
age (operating
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
voltage range)
Current
consumption
15 mA max. at 24 VDC (no-load)
10 mA max.
at 24 VDC (no-load)
Control
output
Load
current
TL-W1R5MC1:
NPN open collector
100 mA max. at 30 VDC max.
TL-W1R5MC1/-W3MB@:
PNP open collector
100 mA max. at 30 VDC max.
TL-W5MC@:
NPN open collector
50 mA max. at 12 VDC
(30 VDC max.)
100 mA max. at 24 VDC
(30 VDC max.)
200 mA
TL-W5MB@:
PNP open collector
50 mA max. at 12 VDC
(30 VDC max.)
100 mA max. at 24 VDC
(30 VDC max.)
2 V max. (under load cur-
rent of 200 mA with cable
length of 2 m)
E1/F1 Models: NO
E2/F2 Models: NC
100 mA max. at 12 VDC
200 mA max. at 24 VDC
Residual
1 V max. (under load current of 100 mA with cable length of 2 m)
voltage
Indicators
Operation mode
(with sensing ob-
ject approaching)
Detection indicator (red)
NO
B1/C1 Models: NO
B2/C2 Models: NC
1 V max. (under load
current of 200 mA with
cable length of 2 m)
Refer to the timing charts under
I/O Circuit Diagrams
on page 6 for details.
Protection circuits
Reverse polarity protection, Surge suppressor
Ambient
Operating/Storage:
−25
to 70°C (with no icing or condensation)
*
temperature range
Ambient
humidity range
Temperature
influence
Voltage influence
Insulation
resistance
Vibration
resistance
Shock resistance
Degree of
protection
Connection
method
Weight
(packed state)
Materi-
als
Case
Sensing
surface
Operating/Storage: 35% to 95% (with no condensation)
±10%
max. of sensing distance at 23°C in the temperature range of
−25
to 70°C
±2.5%
max. of sensing distance at rated
voltage in the rated voltage
±10%
range
±2.5%
max. of sensing
distance at rated volt-
age in the rated voltage
±20%
range
±2.5%
max. of sensing distance at rated voltage in
the rated voltage
±10%
range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s 3 times each in X, Y, and Z directions
IEC 60529 IP67, in-house standards: oil-resistant
*
Pre-wired Models (Standard cable length: 2 m)
Approx. 70 g
Heat-resistant ABS
Heat-resistant ABS
Mounting Bracket, Instruction manual
Instruction manual
Approx. 80 g
Approx. 100 g
Aluminum die-cast
Approx. 210 g
Heat-resistant ABS
2
Destruction: 500 m/s
2
10 times each in X, Y,
and Z directions
Accessories
* For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.
As a newcomer in the workplace, you rack your brains to perform well so as to get the affirmation and praise from your superiors, and thus you fall into the "performance trap" accidentally. "Active pe...
According to the IC industry salary survey report by China Human Resources Management Consulting Co., Ltd., the demand for talent in the IC industry has increased dramatically in recent years, with sa...
[table=98%][tr][td] [align=center] [/align] [size=16px] 1. Naming of 5% accuracy: RS-05K102JT 2. Naming of 1% accuracy: RS-05K1002FT R - indicates resistance S - indicates power 0402 is 1/16W, 0603 is...
The car starts from point A. The longitude and latitude of point A are known (obtained from GPS). There is no GPS signal during the driving process, but the mileage (in kilometers) and the turning ang...
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
Abstract:
With the increasing complexity of smart vehicle electrical and electronic architectures, the full lifecycle management of vehicle electronic control components faces multiple challe...[Details]
Nios II is a configurable 16-/32-bit RISC processor. Combined with a rich set of peripheral-specific instructions and hardware acceleration units, it provides a highly flexible and powerful SOPC sy...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
introduction
The concept of the smart home is gradually developing and gaining market acceptance. We believe its ultimate form lies in the interconnection of all home appliances through open i...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
On August 22, the Wall Street Journal reported on the 21st local time that the new US government does not plan to acquire equity in semiconductor wafer foundry giant TSMC and Micron, one of the thr...[Details]
Inverter power supplies on the market can generally be divided into two categories: sine wave inverters and square wave inverters. Some engineers also like to categorize pure sine wave inverters as...[Details]
Methods of DC motor speed regulation:
1. The voltage regulator can be used to change the input voltage and speed directly, which is often used for large kilowatt-level motors.
2. Thyristo...[Details]
A pure sine wave inverter has a good output waveform with very low distortion, and its output waveform is essentially the same as the AC waveform of the mains power grid. In fact, the AC power prov...[Details]
introduction
As core electronic components used in vastly different fields, automotive-grade chips and mobile/consumer-grade chips exhibit significant differences in their...[Details]
Hair dryer structure and working principle: It is mainly used for drying and shaping hair, but it can also be used for local drying, heating and treatment in laboratories, physiotherapy rooms, ind...[Details]
In this final installment of a five-part blog series, I will discuss noise in op amps driving headphone loads and some techniques for reducing it. Previous posts have discussed headphone load power...[Details]
Silicon Labs (also known as "Silicon Labs"), an innovative leader in low-power wireless connectivity, will showcase its cutting-edge artificial intelligence (AI) and Internet of Things (IoT) solu...[Details]