DCM25-303

Description
Industrial Pressure Sensors FEMA
CategoryThe sensor   
File Size410KB,20 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

DCM25-303 Online Shopping

Suppliers Part Number Price MOQ In stock  
DCM25-303 - - View Buy Now

DCM25-303 Overview

Industrial Pressure Sensors FEMA

DCM25-303 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerHoneywell
Product CategoryIndustrial Pressure Sensors
ProductPressure Switches
Operating Pressure4 bar to 25 bar
Pressure TypeDifferential
Accuracy< 1 %
Port SizeG 1/2, G 1/4
Operating Supply Voltage250 VAC
PackagingBulk
Pressure PortPort
Mounting StylePanel
Maximum Operating Temperature+ 70 C
Minimum Operating Temperature- 25 C
Operating Supply Current8 A
Factory Pack Quantity1
40
Mechanical pressure switches
Liquids and gases
DCM/DNM
Pressure switches and pressure monitors for overpressure
This universal pressure switch can be used in
general mechanical engineering and the printing
machine industry, as well as in pneumatics and
hydraulics.
SIL 2 according IEC 61508-2
DCM25
Technical data
Pressure connection
External thread G 1/2 (pressure gauge
connection) according to DIN 16 288 and inter-
nal thread G 1/4 according to ISO 228 Part 1.
Switching device
Robust housing (200) made of seawater-
resistant diecast aluminium GD Al Si 12.
Protection class
IP 54, in vertical position.
Pressure sensor materials
DNM025…DCM63 Metal bellows: 1.4571
Sensor housing: 1.4104
DCM025 – DCM 1 Metal bellows: Cu Sensor
housing: Cu + Ms
DCM4016/
Diaphragm: Perbunan
DCM4025
Sensor housing: 1.4301
DCM1000
Diaphragm: Perbunan
Sensor housing: Brass
Mounting position
Vertically upright and horizontal. DCM4016
and 4025 vertically upright.
Ambient temp. at switching device
–25…+70 °C, except: DCM4016,
4025, 1000: –15…+60 °C
Max. medium temperature
The maximum medium temperature at the
pressure sensor must not exceed the
permitted ambient temperature at the
switching device. Temperatures may reach
85°C for short periods). Higher medium
temperatures are possible provided the above
limit values for the switching device are
ensured by suitable measures (e.g. siphon).
Mounting
Directly on the pressure line (pressure
gaugeconnection) or on a flat surface with two
4 mm Ø screws.
Switching pressure
Adjustable from outside with screwdriver.
Switching differential
Not adjustable with DCM and types. Adjustable
from outside with DCMV types. For values see
Product Summary.
Contact arrangement
Single-pole changeover switch.
Switching
capacity
Normal
250 VAC 250 VDC 24 VDC
(ohm) (ind) (ohm) (ohm)
8A 5A
0.3 A
8A
Type
Setting range
Switching
Max.
Materials in- Dimen-
differential
permissible contact with sioned
(mean values) pressure
medium
drawing
page 25 + 26
1 + 11
1 + 10
1 + 14
1 + 15
1 + 12
Sensor
housing
1.4104
+
Pressure
bellow
1.4571
1 + 18
1 + 17
Switching differential not adjustable
DCM4016
1…16 mbar
2
DCM4025
4…25 mbar
2
DCM1000
10…100 mbar
12
DCM025
0.04…0.25 bar
0.03
DCM06
0.1…0,6 bar
0.04
DCM1
0.2…1,6 bar
0.04
DNM025
0.04…0.25 bar
0.03
DCM506
15…60 mbar
10
DCM3
0.2…2.5 bar
0.1
DCM6
0.5…6 bar
0.15
DCM625
0.5…6 bar
0.25
DCM10
1…10 bar
0,3
DCM16
3…16 bar
0.5
DCM25
4…25 bar
1.0
DCM40
8…40 bar
1.3
DCM63
16…63 bar
2.0
mbar 1
mbar 1
mbar 10
bar
6
bar
6
bar
6
bar
6
mbar 12
bar 16
bar 16
bar 25
bar 25
bar 25
bar 60
bar 60
bar 130
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
Perbunan
+ 1.4301
Perbunan + MS
Cu + Ms
Cu + Ms
Cu + Ms
1 + 16
Switching differential adjustable
DCMV025
0.04…0.25 bar
0.03…0.4 bar
DCMV06
0.1…0.6 bar
0.04…0.5 bar
DCMV1
0.2…1.6 bar 0.07…0.55 bar
DCMV3
0.2…2.5 bar
0.15…1.5 bar
DCMV6
0.5…6 bar
0.25…2.0 bar
DCMV625
0.5…6 bar
0.25…2.0 bar
DCMV10
1…10 bar
0.5…2.8 bar
DCMV16
3…16 bar
0.7…3.5 bar
DCMV25
4…25 bar
1.3…6.0 bar
DCMV40
8…40 bar
2.6…6.6 bar
DCMV63
16…63 bar
3.0…10 bar
6
6
6
16
16
25
25
25
60
60
130
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
bar
Cu + Ms
Sensor
housing
1.4104
+
Pressure
bellow
1.4571
1 + 14
1 + 18
1 + 17
1 + 16
For smaller pressure ranges see also VCM, DGM, HCD and DPS sheets.
For additional functions refer page 30 – 32.
Calibration
The
DCM
series is calibrated for falling pressure. This means that the adjustable switching pressure on
the scale corresponds to the switching point at falling pressure. The reset point is higher by the amount
of the switching differential. (See also page 27, 1. Calibration at lower switching point).
-DCM/DNM
see page 65
s
Protection Class:
IP 54
[Introduction to M4 Development Board] EKK-LM4F232 explores the hibernate function of M4
Hibernation moduleThe Hibernation module provides a means of reducing power consumption by managing the removal and restoration of power. When the processor and peripherals are idle, power can be comp...
蓝雨夜 Microcontroller MCU
OEM batteries encounter "intellectual property gate"
[b]Special topic motivation[/b] Some scholars believe that Guangdong is facing many major problems that need to be solved in the process of modern industrial upgrading, among which the most prominent ...
songrisi Power technology
Does anyone know the principle of microcontroller reset (I mean inside the microcontroller)?
I was bored, so I thought about this question! I am not referring to the common RC reset and pulse reset. I want to know the internal situation of the microcontroller. After receiving the reset pulse,...
通宵敲代码 MCU
[TI millimeter wave radar evaluation]_6_AWR1843BOOST UART output data analysis 1
[i=s]This post was last edited by lbbook on 2020-1-1 14:03[/i]Series of posts: 1. AWR1843BOOST unboxing 2. Use of AWR1843BOOST 3. AWR1843BOOST corridor ranging value test environment 4. AWR1843BOOST c...
lbbook TI Technology Forum
"The timid ones will be frightened to death, and the brave ones will be fed to death"
"The timid will be scared to death, and the bold will die of their gluttony" - Complaints from Chinese small and medium-sized business owners A small and medium-sized business owner who has been makin...
babbage Automotive Electronics
【KW41 Design Competition】4. Task division of vibration monitor based on UCOS III
[i=s]This post was last edited by azhiking on 2017-7-20 22:03[/i] [b]Task division of vibration monitor based on UCOS III[/b][align=left]As shown in the figure below, the entire vibration monitor is d...
azhiking NXP MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 929  1791  1407  2128  601  19  37  29  43  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号