76575-00000031-01 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerHoneywell
Product CategoryIndustrial Pressure Sensors
ProductPressure Switches
Factory Pack Quantity1
Set Points from 0.5 to 150 psi
5000 Series
Extended Duty Pressure Switch With Direct Action Blade Contacts
The 5000 Series switch is specifically
designed to stand up to extended duty
applications. This switch is factory set
but capable of field adjustment. It
features a Kapton diaphragm for
compatibility with a wide variety of
fluids, and various terminations
including a Metri-Pack connector that
forms a tight seal when connected.
Among the outstanding design benefits
are its durable construction, compact
size, and enhanced set point integrity.
Standard Specifications
Type:
Direct action
blade contact
Contacts:
Silver alloy,
gold plated
Set Point:
Factory set
from 0.5 to 150 PSI
Operating Pressure:
150 PSI for 0.5-24 PSI set point range,
250 PSI for 25-150 PSI set point range
Proof Pressure:
500 PSI
Burst Pressure:
750 PSI for 0.5-24 PSI
set point range
1250 PSI for 25-150 PSI
set point range.
Ratings:
Resistive:
15
8
4
Inductive:
1
0.5
AMP-
AMP-
AMP-
AMP-
AMP-
6
12
24
120
240
VDC
VDC
VDC
VAC
VAC
Switch Boot P/N 79380
for Vacuum and Pressure
2.9” REF.
Diaphragm:
Polyimide film
2.3” REF.
Temperature
Range:
Connector:
Terminals:
-40° F to + 250° F
1/8
-27 NPT male thread
#8-32 screws,
1/4” blade,
280 Series Metri-Pack
Circuitry:
SPST-N.O., N.C.,
1 circuit adjustable dual
circuit, or 2 circuits
adjustable dual circuit.
Also available are
N.O./N.O. dual circuit
and N.C./N.C. dual circuit.
5000 Series Switch
with Metri-Pack Terminal
1.47” REF.
1.47” REF.
5000 Series Switch
with Screw Terminals
Base:
Cover:
Options:
Plated Steel
Glass reinforced polyester
Brass, plastic or stainless
steel base; various base
connector thread sizes;
wire leads (potted & sealed).
NOTE:
OPERATING MEDIA (PRESSURE SWITCH)
The pressure switch is designed to operate with air,
motor oils, transmission oils, jet fuels and other similar
hydrocarbon media.
4

76575-00000031-01 Related Products

76575-00000031-01 76575-00000060-01 76575-B00000060-01 76575-00000050-05 76575-B00000070-05 76575-B00000070-01 76575-B00000040-01 76575-00000040-05
Description Industrial Pressure Sensors PRESSURE SWITCH Industrial Pressure Sensors PRESSURE SWITCH Industrial Pressure Sensors PRESSURE SWITCH Industrial Pressure Sensors PRESSURE SWITCH Industrial Pressure Sensors PRESSURE SWITCH Industrial Pressure Sensors PRESSURE SWITCH Industrial Pressure Sensors PRESSURE SWITCH Industrial Pressure Sensors PRESSURE SWITCH
Product Attribute Attribute Value Attribute Value Attribute Value Attribute Value Attribute Value Attribute Value Attribute Value Attribute Value
Manufacturer Honeywell Honeywell Honeywell Honeywell Honeywell Honeywell Honeywell Honeywell
Product Category Industrial Pressure Sensors Industrial Pressure Sensors Industrial Pressure Sensors Industrial Pressure Sensors Industrial Pressure Sensors Industrial Pressure Sensors Industrial Pressure Sensors Industrial Pressure Sensors
Product Pressure Switches Pressure Switches Pressure Switches Pressure Switches Pressure Switches Pressure Switches Pressure Switches Pressure Switches
Factory Pack Quantity 1 1 1 1 1 1 1 1
Printing issues under EVC
I created a single-document project with printing function using EVC. I want to implement the direct printing function, that is, to print directly by pressing the print button without popping up the s...
yunfei1019 Embedded System
Show off the engraving machine that is about to be completed
[i=s]This post was last edited by deweyled on 2014-5-3 21:49[/i] I started working overtime after the Chinese New Year, and I still made some things bit by bit. I finally had time to do a complete wel...
deweyled Creative Market
What is the problem with Tornado when downloading?
I installed tornado2.2 and wrote a simple helloworld program, but an error occurred during download: error: image specified cannot be run as a vxworks simulator with processor number 0. What is going ...
ydq850524 Embedded System
Need a part-time Linux programmer in Beijing
We need a part-time Linux programmer in Beijing who can independently complete the following development. If you do not meet the requirements, please do not disturb us to avoid wasting our time. We ar...
wanglicha Linux and Android
SHP Selection for ADC
SHP 0 The sampling signal comes from the sampling trigger input signal; 1 The sampling signal comes from the sampling timer. Is there any difference between the two? ? In what circumstances should we ...
s364147694 Microcontroller MCU
Analog Circuit
The action mode of the components (devices) in the circuit belongs to the circuit with linear change. Usually the emphasis is on the amplification factor, signal-to-noise ratio, operating frequency an...
fighting Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1170  1279  2227  2405  1885  24  26  45  49  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号