EEWORLDEEWORLDEEWORLD

Part Number

Search

DGM525-513

Description
Industrial Pressure Sensors FEMA
CategoryThe sensor   
File Size449KB,22 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

DGM525-513 Online Shopping

Suppliers Part Number Price MOQ In stock  
DGM525-513 - - View Buy Now

DGM525-513 Overview

Industrial Pressure Sensors FEMA

DGM525-513 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerHoneywell
Product CategoryIndustrial Pressure Sensors
ProductPressure Switches
Operating Pressure100 mbar to 250 mbar
Pressure TypeDifferential
Accuracy< 1 %
Port SizeG 1/2, G 1/4
Operating Supply Voltage250 VAC
PackagingBulk
Pressure PortPort
Mounting StylePanel
Maximum Operating Temperature+ 60 C
Minimum Operating Temperature- 25 C
Operating Supply Current8 A
Factory Pack Quantity1
58
Mechanical pressure switches
Tested to PE Directive 97/23/EC
DGM
Pressure monitors for fuel gases
DVGW tested to DIN EN1854
Gas pressure monitors are suitable
for all gases in accordance with DVGW
Worksheet G260 and for air.
SIL 2 according IEC 61508-2
DGM310A
Technical data
Pressure connection
External thread G 1/2 to DIN 16 288 and
internal thread G 1/4 to ISO 228 Part 1
(permissible up to 4 bar).
Switching device
Seawater-resistant diecast aluminium
GD AI Si 12.
Protection class
IP 54 for vertical installation position.
Pressure sensor materials
See Product Summary
Ambient temperature
–25 to +60°C.
At ambient temperatures below 0°C, ensure
that condensation cannot occur in the sensor
or in the switching device.
Maximum working pressure
See Product Summary
Mounting
Either directly on the pipe or with
two 4 mm ø screws on the wall surface.
Mounting position
Vertically upright and horizontal.
Setting
Continuously adjustable via the setting spindle
with a screwdriver. The set switching pressure
is visible in the scale window.
Sealing P2
On request (can be fitted later).
Switching differentials
Largely independent of the set switching
pressure. Not adjustable. For values see
Product Summary.
Switching
capacity
Normal
250 VAC 250 VDC 24 VDC
(ohm) (ind) (ohm) (ohm)
8A 5A
0.3 A
8A
Component tested for
Testing basis
Function
Fuel gases according to DVGW Worksheet G 260
DIN EN1854
Pressure monitor
Direction of action
For maximum and minimum
pressure monitoring
Product Summary
Type
Setting range
Switching
Max.
differential
working
(mean values) pressure
Materials
Dimen-
in contact
sioned
with medium drawing
p. 25 + 26
DGM306A
DGM310A
DGM325A
DGM06A
DGM1A
DGM506
DGM516
DGM525
15…60
20…100
40…250
100…600
0.2…1.6
15…60
40…160
100…250
mbar
mbar
mbar
mbar
bar
mbar
mbar
mbar
6
7
10
25
40
8
12
20
mbar
mbar
mbar
mbar
mbar
mbar
mbar
mbar
0.8
0.8
0.8
2
3
5
5
5
bar
bar
bar
bar
bar
bar
bar
bar
CU + Ms
CU + Ms
CU + Ms
CU + Ms
CU + Ms
1.4104
1.4104
1.4104
1 + 13
1 + 14
1 +12
Calibration
The
DGM
series is calibrated for rising pressure. This means that the adjustable switching pressure on
the scale corresponds to the switching point at rising pressure. The reset point is lower by the amount of
the switching differential. (See also page 27, 2. Calibration at upper switching point).
For other pressure ranges see type series DWR, page 59.
Ex-i version (intrinsically safe)
As above, but with additional function ZF513 (Ex-i).
Example for ordering:
DGM516-513
Pressure measuring connection
Care must be taken to ensure that a pressure
measuring connection is available in a suitable
place on the gas appliance.
-DGM see page 70
s
DVGW
TÜV
Protection Class:
IP 54
[Silicon Labs BG22-EK4108A Bluetooth Development Review] Part 1: Unboxing
Preface I have never used silicon chips before, and I know nothing about this brand. I remember it was a gecko logo. I was lucky enough to participate in the review this time, so I started to understa...
jj1989 Development Kits Review Area
Help with development board configuration issues
If you want to create a device that can output audio and video on a TV and have a built-in browser to browse server web pages, what kind of necessary configuration would you need?...
shinesnow Embedded System
Where to download the fast algorithm function library of c2000
Where can I download the fast algorithm library of c2000? Or can anyone provide it and share it?...
l0700830216 Microcontroller MCU
VS2005 and development board connection problem
Hey experts, I am developing a program with PCM-3586 (CPU: vortex86DX) board, and now I have encountered a very difficult problem, that is, the development board cannot be connected to vs2005 to debug...
znstchhh Embedded System
Problems with RegOpenKeyEx in dynamic libraries and exe
Dear seniors: The same code in the dynamic library calls RegOpenKeyEx RegCreateKeyEx and returns -11881138260 instead of ERROR_SUCCESS, while using EVC debugging returns 0, which is ERROR_SUCCESS. Has...
kids Embedded System
ucosii was successfully ported to STM32F103, here is the source code
ucosii was successfully ported to STM32F103, here is the source code...
zhaoyuyhq Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 804  1316  178  559  1939  17  27  4  12  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号