EEWORLDEEWORLDEEWORLD

Part Number

Search

DWAM32

Description
Industrial Pressure Sensors FEMA
CategoryThe sensor   
File Size883KB,25 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

DWAM32 Online Shopping

Suppliers Part Number Price MOQ In stock  
DWAM32 - - View Buy Now

DWAM32 Overview

Industrial Pressure Sensors FEMA

DWAM32 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerHoneywell
Product CategoryIndustrial Pressure Sensors
ProductPressure Switches
Operating Pressure6 bar to 32 bar
Pressure TypeDifferential
Accuracy< 1 %
Port SizeG 1/2, G 1/4
Operating Supply Voltage250 VAC
PackagingBulk
Pressure PortPort
Mounting StylePanel
Maximum Operating Temperature+ 70 C
Minimum Operating Temperature- 20 C
Operating Supply Current8 A
Factory Pack Quantity1
DWAM, DWAMV, SDBAM
Pressure monitors / pressure limiters
These series are particularly suitable for
maximum pressure monitoring in steam and
hot-water systems. The pressure switch is
"of special construction", with a self-monitoring
pressure sensor, built in accordance with
Pressure Equipment Directive PED 97/23/EC.
It can be used as a pressure monitor or
a pressure limiter for maximum pressure
monitoring (systems in accordance with
TRD 604 DIN EN12828) systems in
accordance with DIN EN12952-11 and
DIN EN12953-9 and is available with or
without adjustment.
SIL 2 according IEC 61508-2
DWAM1
Technical data
Pressure connection
External thread G 1/2 (pressure gauge
connection) to DIN 16 288 and internal
thread G 1/4 to ISO 228 Part 1.
Switching device
Rugged housing (200) made of seawater-
resistant diecast aluminium.
Materials
Pressure bellows: Material no. 1.4571
Sensor housing: Material no. 1.4104
Switch housing: GD AI Si 12
according to DIN 1725
Mounting position
Vertically upright and horizontal.
Ambient temperature at switching device
–20 to +70°C.
Medium temperature
–20 to +70°C.
The maximum medium temperature at the
pressure sensor must not exceed the permitted
ambient temperature at the switching device.
Temperatures may reach 85°C for short
periods. Higher medium temperatures are
possible provided the upper limit at the
switching device is ensured by suitable
measures (e.g. siphon).
Mounting
Directly on the pressure line (pressure gauge
connection) or on a flat surface with two
4 mm Ø screws.
Calibration for maximum pressure switch
The pressure monitors and safety pressure
limiting devices are calibrated so that,
under
rising pressure,
switching takes place at the
defined switching pressure. The reset point
under falling pressure is lower by the amount of
the switching differential, or, in the case of
pressure limiting devices, by the fall in pressure
specified in the table. The scale value
corresponds to the upper switching point.
Switching differential
See Product Summary.
Contact arrangement
Single-pole changeover switch.
Switching
250 VAC 250 VDC 24 VDC
capacity
(ohm) (ind) (ohm) (ohm)
Normal
8A 5A
0.3 A
8A
Sealing P2
Generally available for SDBAM limiters.
Bursting pressure
For all types
100 bar.
Verified by TÜV test.
Component tested for
Testing basis
Function
Directing of action
Sensor
Pressure monitor / Pressure limiter
For maximum pressure monitoring only
"Of special construction"
(self-monitoring sensor with
safety diaphragm)
Product Summary Maximum pressure monitoring ( )
(for other pressure ranges see DWR series)
Type
Setting range
Switching
Max.
Dimen-
differential
permissible
sioned
(mean values)
pressure
drawing
Pressure monitors without differential adjustment
for max. pressure monitoring
page 21 + 22
DWAM06
0.1…0.6 bar
0.04 bar
5 bar
DWAM1
0.2…1.6 bar
0.05 bar
5 bar
1 + 15
DWAM6
1.2…6 bar
0.2
bar
10 bar
DWAM625
1.2…6 bar
0.25 bar
20 bar
DWAM16
3…16 bar
0.4
bar
20 bar
1 + 19
DWAM32
6…32 bar
1.2
bar
45 bar
Pressure monitors with differential adjustment for max. pressure monitoring
DWAMV1
0.2…1.6 bar
0.12…0.6 bar
5 bar
1 + 15
DWAMV6
1.2…6 bar
0.4…1.5 bar
10 bar
DWAMV16
3…16 bar
0,8…2,5 bar
20 bar
1 + 19
DWAMV32
6…32 bar
2.5…6.0 bar
45 bar
Pressure limiters for maximum pressure monitoring (with internal interlock)
Pressure change
for unlocking
SDBAM1
0.2…1.6 bar
0.12 bar
5 bar
SDBAM2,5
0.4…2.5 bar
0.15 bar
5 bar
1 + 15
SDBAM6
1.2…6 bar
0.4 bar
10 bar
SDBAM625
1.2…6 bar
0.6 bar
20 bar
SDBAM16
3…16 bar
0.8 bar
20 bar
1 + 19
SDBAM32
6…32 bar
3.0 bar
45 bar
* If a downstream external interlock is added, DWAM... pressure monitors can also be used
as pressure limiters (see page 51).
· Sealing device P2 is included for SDBAM limiters and can also be retrofitted to pressure monitors on
request. See sealing P2.
· DWAM... also available in Ex-i equipment. See DBS series.
s
tested
Protection Class:
IP 54
Accessories
Minimum pressure controls
– Minimum pressure monitor: DWR… page 50
– Minimum pressure limiter: DWR…-206 page 56
Solenoid valves
Flow monitors
Temperature sensors
Thermostats
Steam
Systems according to TRD 604
Hot water
Systems according to DIN EN12828
VdTÜV Memorandum "Pressure 100"
Pressure transmitters
Pressure switches
Mechanical pressure switches
Tested to PE Directive 97/23/EC
49
A good book
It's a rare good book. Come and download it....
xupeilinhong Test/Measurement
LA76810 Data Sheet
LA76810 is a large-scale integrated circuit successfully developed by Sanyo in 1999 for PAL/NTSC color TV signal processing. The single chip can complete the demodulation of image and audio, color dec...
rain FPGA/CPLD
msp430F5418 normal mode and low power mode switching time
I am using the low power mode of the msp430F5418 microcontroller. The data sheet says that the time to enter low power is microseconds, but I tested it myself and found that it takes 18 seconds for th...
macro Microcontroller MCU
A question about signals and systems
When the recorder plays faster, the sound will become higher. This is because the frequency spectrum of the electrical signal becomes wider. But why does the frequency spectrum of the sound become wid...
stream Analog electronics
Proteus Pro 7.4 sp3.part02.rar
Proteus Pro 7.4 sp3.part02.rar...
CX4359481 MCU
What effect does internal resistance have on power supply?
[size=4]When learning about current source and voltage source, the question about the internal resistance of the power supply often confuses many people. They only remember that when the voltage sourc...
fish001 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2519  610  1283  2096  1181  51  13  26  43  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号