EEWORLDEEWORLDEEWORLD

Part Number

Search

KLNR80

Description
FAST BLOW ELECTRIC FUSE, 600A, 250VAC, 125VDC, 200000A (IR), INLINE/HOLDER
CategoryCircuit protection    Circuit protection   
File Size179KB,2 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

KLNR80 Overview

FAST BLOW ELECTRIC FUSE, 600A, 250VAC, 125VDC, 200000A (IR), INLINE/HOLDER

KLNR80 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
Base Number Matches1
General Purpose Fuses
KLNR/KLSR Class RK1 Fuses
250/600 VAC • Fast Acting • 1 – 600 Amperes
Applications
Resistance heaters
Lighting circuits
Non-inductive loads
Molded case circuit breaker load centers and panelboards have
increased interrupting ratings when series rated with Littelfuse
KLNR/KLSR Class RK1 fuses. Refer to panelboard manufacturer’s
literature for UL Listed combination of fuses and panelboards. Series
ratings up to 200,000 amperes are available.
General Purpose Fuses
Safety
• 200,000 A.I.R. — Reliable interruption of all overcurrents up to
200,000 amperes.
• Extremely current-limiting — Stops damaging short-circuit current
faster than any mechanical protective device.
• Fast-acting — Provides fast acting protection to equipment such
as variable speed drives, rectifiers and other equipment containing
surge-sensitive components.
Longer Equipment Life
• Current-limiting design reduces damage to equipment caused by
heating and magnetic effects of short-circuit currents.
Economical
KLNR/KLSR series RK1 fuses were the earliest type of current-limiting
fuses developed. Their single-element, silver link design enables them
to provide fast-acting overload and short-circuit protection. When used
to protect inductive loads such as motors, solenoids, and transformers,
KLNR/KLSR series fuses must be greatly oversized to prevent opening
the fuses on harmless in-rush currents. In such applications, KLNR/
KLSR series fuses may only provide short-circuit protection.
We recommend using POWR-PRO
®
LLNRK/LLSRK series Class RK1,
dual-element, time-delay fuses in all new applications requiring the
current-limiting ability of UL Class RK1 fuses. POWR-PRO LLNRK/
LLSRK series fuses are also recommended in existing applications
where fast-acting RK1 or RK5 fuses have been opening on harmless
system surges such as motor starting currents.
• Extremely current-limiting — often permits use of readily available,
less costly equipment.
• Used as input or output fuses for surge sensitive components such
as variable speed drives and rectifiers, fast acting KLNR/KLSR fuses
may prevent opening of expensive semiconductor fuses protecting
individual components.
Easy To Use
• 200,000 A.I.R. rating minimizes need for short-circuit calculations.
Dimensions
• Refer to FLNR_ID for KLNR dimensions and FLSR_ID for KLSR
dimensions.
Specifications
Voltage Ratings:
AC: 250 Volts (KLNR); 600 Volts (KLSR)
DC: 125 Volts (1 – 600A KLNR);
250 Volts (1 – 30A KLSR);
300 Volts (35 – 600A KLSR).
AC: 200,000 am­peres rm­s sym­m­etrical
DC: 20,000 am­peres
1 – 600 am­peres.
AC: Standard 248-12, Class RK1
UL Listed (File No: E81895)
CSA Certified (File No: LR29862)
DC: Littelfuse self-certified
Ampere Ratings
1
2
3
4
5
6
8
10
12
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225
250
300
350
400
450
500
600
Interrupting Ratings:
Ampere Range:
Approvals:
Exam­ple part num­ber (series & am­perage): KLNR 200
Recommended Fuse Blocks
LR250 series (for KLNR series fuses)
LR600 series (for KLSR series fuses)
Refer to the Blocks & Holders section of this catalog for additional inform­ation.
34
www.littelfuse.com
© 2005 Littelfuse
POWR-GARD
Products Catalog
imgdecmp.dll
Excuse me, who has the imgdecmp.dll file, can you send me a copy? Thank you! Email: 47097248@qq.com...
hjacky Embedded System
About the problem of sending and receiving data of ucos+STM32
I have encountered a problem in the past few days, that is, when the interrupt receives data and sends it out, if the previous frame of data is not sent out before this frame of data comes in, the dat...
小小小小菜鸟 Real-time operating system RTOS
Part 3: A Preliminary Look at RISC-V
RISC-V (pronounced "risk-five") is a free and open source instruction set architecture (ISA) that ushers in a new era of processor innovation through open standards collaboration. Founded in 2015, the...
常见泽1 Domestic Chip Exchange
LCD screen
Here comes the useful stuff! Here comes the useful stuff! Application example : Curve application usingTOPWAY Smart LCD (HMT070CR-C) The first step is to create a project①Open TOPWAY TML Graphic Edito...
慈俭不敢为人先 Industrial Control Electronics
Friends who are doing ARM embedded development in Beijing, come and join us~!
[b][color=#ff0000]Embedded learning information broadcast: Sharing is the greatest happiness~! [/color][/b] Beijing Beihang University January 16 afternoon theme: Embedded software and hardware develo...
bjfarsighttop ARM Technology
Read the pin GPIOPinRead(), but can't read it!
I used gpio=GPIOPinRead(GPIO_PORTD_BASE, GPIO_PIN_7); to read the pin, but the external PD7 was given a high level, and the read data was all zero. Can anyone help me?...
wsw92 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1545  1902  228  1468  1377  32  39  5  30  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号