Railway/Transportation system applications including communications systems, informa-
tion display, lighting, control systems, ticket machines, passenger
entertainment, public address systems, door control, industrial power systems and power
generation systems.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V110C12C100BL
110C
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
50W
5V
75W, 125W
8V
75W
12V
100W
15V
100W, 150W
24V
100W, 150W
28V
100W
36V
100W
48V
100W, 150W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
110V Micro Family
Page 1 of 13
Rev 4.1
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
54
155.5
64
56
161.7
169.4
1.3
Min
66
Typ
110
Max
154
250
65.4
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
Per EN50155 and GBT-25119
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 8.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.24
0.21
10.9
2.8
48
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
110V Micro Family
Page 2 of 13
Rev 4.1
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting
Agency approvals
1.9
(52.8)
2.1
(58.7)
100
Min
3000
1500
500
10
2.1
(59.3)
2.3
(65.2)
115
cURus, cTÜVus, CE
2.3
(65.8)
2.5
(71.7)
Typ
Max
Unit
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
110V Micro Family
Page 3 of 13
Rev 4.1
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3V
OUT
, 50W (e.g. S110C3V3C50BL, V110C3V3C50BL)
Parameter
Efficiency
S110C3V3C50BL (enhanced efficiency)
V110C3V3C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
81.0
78.8
4.14
Typ
85.0
79.8
124
4.3
1.7
±0.02
17.5
17.5
Max
Unit
%
157
4.46
2.7
±0.2
15.15
20.6
20.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.5
10.6
5V
OUT
, 125W (e.g. S110C5C125BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.0
6.03
Typ
86.8
120
6.25
3.1
±0.02
28.8
28.8
Max
150
6.47
6.2
±0.2
25
33.8
33.8
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
17.5
5V
OUT
, 75W (e.g. S110C5C75BL, V110C5C75BL)
Parameter
Efficiency
S110C5C75BL (enhanced efficiency)
V110C5C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.9
82.6
6.03
Typ
86.5
83.6
92
6.25
3.3
±0.02
17.3
17.3
Max
Unit
%
115
6.47
5.4
±0.2
15
20.3
20.3
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.3
10.5
8V
OUT
, 75W (e.g. S110C8C75BL, V110C8C75BL)
Parameter
S110C8C75BL (enhanced efficiency)
V110C8C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.5
83.0
9.36
Typ
87.5
84.3
280
9.7
2.6
±0.02
10.8
10.8
Max
Unit
%
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
9.56
6.56
350
10.1
3.5
±0.2
9.38
12.7
12.7
mV
Volts
Watts
%
Amps
Amps
Amps
110V Micro Family
Page 4 of 13
Rev 4.1
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
12V
OUT
, 100W (e.g. S110C12C100BL, V110C12C100BL)
Parameter
Efficiency
S110C12C100BL (enhanced efficiency)
V110C12C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.2
87.0
13.7
Typ
89.5
88.2
150
14.3
3.1
±0.02
9.58
9.58
Max
Unit
%
188
14.9
5.1
±0.2
8.33
11.3
11.3
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
8.49
5.83
15V
OUT
, 150W (e.g. S110C15C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.7
17.1
Typ
88.2
140
17.8
5.5
±0.02
11.5
11.5
Max
175
18.5
7.5
±0.2
10
13.5
13.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
0
10.2
7.0
15V
OUT
, 100W (e.g. V110C15C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.5
17.1
Typ
84.5
100
17.8
4
±0.02
7.67
7.67
Max
125
18.5
5
±0.2
6.67
9.01
9.01
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
6.8
4.66
24V
OUT
, 150W (e.g. V110C24C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.2
27.2
Typ
88.7
131
28.2
4.6
±0.02
7.2
7.2
Max
164
29.2
6.0
±0.3
6.25
8.4
8.4
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
Hello everyone, I wrote a TDI driver, using TCP protocol, the main purpose of this driver is to send data to the server. But I am surprised that the efficiency of send is very low, but the efficiency ...
Does nrf24e1 only have 11 I/O ports? Or does it not include the normal P0, P1, and P2 of the 51 core? I plan to make a simple unlimited ordering system based on nrf24e1. Because I need to use a keyboa...
Summer is here, and the white-collar workers in the office are wearing cooler and cooler clothes. Their small skirts, small tube tops, and exquisite makeup seem to make the atmosphere of the whole off...
It is possible to open the routine directly, but it is not conducive to developing your own project. If you want to develop your own stuff anytime and anywhere. It is very simple to create your own te...
Emergency hand-held lamps powered by 6V maintenance-free batteries are widely used in rural areas. The charger used is a transformer step-down and single diode half-wave rectifier, and the charging...[Details]
When the WDP500-2A plane grating monochromator is used to test the emission wavelength of a high-power laser diode at different currents, the matching of the laser diode has the disadvantages of lo...[Details]
1. Introduction
This design was made for participating in an electronic design competition. It effectively solved the problem of the operation and control of an electric car on a seesaw. The s...[Details]
Do you often have to add brake fluid to your car's brakes? The fact that you need to pump out the brake fluid to make sure there is no gas in the brake fluid line may not be done by the car owner h...[Details]
With the advent of increasingly powerful processors, image sensors, memory, and other semiconductor devices, as well as the algorithms that enable them, computer vision can be implemented in a wide...[Details]
For a long time, due to the limitation of hardware conditions, the display devices of traditional small handheld devices such as PDA are usually monochrome LCD, and the user interface is very simpl...[Details]
This paper establishes a fuel cell engine test platform based on the NI integrated hardware and software environment. This platform can realize the test and control of fuel cell engines and their a...[Details]
1. Introduction to CIF Board
Fieldbus integration based on PC system
Whether it is a master or a slave, fieldbus has won unanimous praise in the field of PC-based automation. For more...[Details]
LED lamps and bulbs are now rapidly replacing incandescent, halogen and CFL (compact fluorescent lamp) light sources in many general lighting applications. Flyback DC/DC converters are the power su...[Details]
0 Introduction
With the rise and continuous improvement of the solid-state lighting industry, light-emitting diodes (LEDs) have become an alternative lighting technology and are gr...[Details]
With the rapid development of intelligent control technology, computers and information technology, the trend of information appliances IA (Information Application), computers and communications integ...[Details]
In recent years, with the rapid development of the information industry, dot matrix LED display screens have been widely used in various advertising and information display systems such as the fina...[Details]
With the advocacy and implementation of the government's Safe City Plan, the security market has increasingly higher requirements for the clarity of surveillance images. Imagine that after a case o...[Details]
As people's requirements for safety and comfort in the process of driving cars continue to increase, automotive radars are widely used in the car's adaptive cruise system, collision avoidance syste...[Details]
Today, the value of electronic components in cars accounts for 15-20% of the total vehicle. In the future, this proportion may be as high as 30-40% as more safety electronics, fuel consumption and ...[Details]