Industrial and process control, distributed power, medical, ATE, communications,
defense, and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Parameter
+IN to –IN voltage
PC to –IN voltage
PR to –IN voltage
SC to -OUT voltage
-Sense to -OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
-0.5 to +53
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
1.0
3000
1500
500
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
*Derate power to 75% for 9-10V
IN
Part Numbering
e.g. V28B24T150BL2
28B
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail. ≤12
V
OUT
only)
Output Voltage
3 V3
= 3.3 V
5
= 5V
8
= 8V
12
= 12 V
15
= 15 V
24
= 24 V
28
= 28 V
36
= 36 V
48
= 48 V
Product Grade Temperatures (°C)
Grade
Operating
Storage
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
B
Output Power
V
OUT
P
OUT
3.3 V
5V
12 V
15 V
24 V
28 V
36 V
48 V
75
W
75
W
125
W
150
W
150
W
150
W
150W
150
W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
28V Wide Mini Family
Page 1 of 11
Rev 2.4
06/2017
vicorpower.com
800 927.9474
28V Wide Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
7.37
36.3
8.73
7.64
37.8
12.0
39.6
14.0
Min
9
Typ
24
Max
36
50
8.95
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
Notes
From 9 to 10V input available power is reduced to
75% of max rating.
<100ms
mA
PC pin low
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
%/°C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
12V
15V
24V
28V
36V
48V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 6.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.16
0.14
8.0
1.9
83
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
28V Wide Mini Family
Page 2 of 11
Rev 2.4
06/2017
vicorpower.com
800 927.9474
28V Wide Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
3.1
(89.3)
3.5
(99.6)
100
3000
1500
500
10
3.5
(100.3)
3.9
(110.6)
115
cURus, cTÜVus, CE
3.9
(111.3)
4.3
(121.6)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
28V Wide Mini Family
Page 3 of 11
Rev 2.4
06/2017
vicorpower.com
800 927.9474
28V Wide Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3
V
OUT
, 75W (e.g. S28B3V3C75BL, V28B3V3C75BL)
Parameter
Efficiency
S28B3V3C75BL (enhanced efficiency)
V28B3V3C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
78.0
76.7
4.14
Typ
83.0
77.7
60
4.3
5.2
±0.02
26.1
26.1
Max
Unit
%
75
4.46
5.8
±0.2
22.73
30.7
30.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
For Vin 9 - 10V, load current 17.05A max.
Output voltage 95% of nominal
Output voltage <250mV
0
23.1
15.8
5
V
OUT
, 75W (e.g. S28B5C75BL, V28B5C75BL)
Parameter
Efficiency
S28B5C75BL (enhanced efficiency)
V28B5C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
75.0
71.8
6.03
Typ
79.0
73.3
252
6.25
5.8
±0.02
17.3
17.3
Max
Unit
%
315
6.47
6.5
±0.2
15
20.3
20.3
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
For Vin 9 - 10V, load current 11.25A max.
Output voltage 95% of nominal
Output voltage <250mV
0
15.3
10.5
12
V
OUT
, 125W (e.g. S28B12C125BL, V28B12C125BL)
Parameter
Efficiency
S28B12C125BL (enhanced efficiency)
V28B12C125BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.0
79.3
13.7
Typ
85.0
80.8
290
14.3
8.2
±0.02
12.0
12.0
Max
Unit
%
363
14.9
9.4
±0.2
10.4
14.1
14.1
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
For Vin 9 - 10V, load current 7.8A max.
Output voltage 95% of nominal
Output voltage <250mV
0
10.6
7.3
15
V
OUT
, 150W (e.g. V28B15C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.5
17.1
Typ
83.9
328
17.8
6.8
±0.02
11.5
11.5
Max
410
18.5
7.8
±0.2
10
13.5
13.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
For Vin 9 - 10V, load current 7.5A max.
Output voltage 95% of nominal
Output voltage <250mV
0
10.2
7
28V Wide Mini Family
Page 4 of 11
Rev 2.4
06/2017
vicorpower.com
800 927.9474
28V Wide Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
24
V
OUT
, 150W (e.g. V28B24C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
78.5
27.1
Typ
81.0
448
28.1
8.9
±0.02
7.19
7.19
Max
560
29.1
10.5
±0.2
6.25
9.2
9.2
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
For Vin 9 - 10V, load current 4.69A max.
Output voltage 95% of nominal
Output voltage <250mV
0
6.37
4.37
28
V
OUT
, 150W (e.g. V28B28C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
79.4
31.5
Typ
80.9
360
32.7
9.6
±0.02
6.16
6.16
Max
450
33.9
10.9
±0.2
5.36
7.24
7.24
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
For Vin 9 - 10V, load current 4.02A max.
Output voltage 95% of nominal
Output voltage <250mV
0
5.46
3.75
36
V
OUT
, 150W (e.g. V28B36C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
78.8
40.4
Typ
79.8
320
41.9
9
±0.02
4.8
4.8
Max
400
43.4
10
±0.2
4.17
5.63
5.63
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
For Vin 9 - 10V, load current 3.13A max.
Output voltage 95% of nominal
Output voltage <250mV
0
4.25
2.91
48
V
OUT
, 150W (e.g. V28B48C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
80.5
53.7
Typ
81.8
320
55.7
5.6
±0.02
3.6
3.6
Max
400
57.7
14
±0.2
3.13
4.23
4.23
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
[i=s]This post was last edited by rinfen on 2022-6-12 17:00[/i]Due to the rapid business development, the leading domestic automotive electronics companies are recruiting for the following positions. ...
1.1 Macro definition clock comment//Macro definition of external clock, setting the clock is very important#define EXTAL_IN_XT1_HZ (32768)#define EXTAL_IN_XT2_HZ (4000000)//Macro definition of interna...
DSP is a high-performance digital signal processor. Due to its fast computing power and powerful information processing capabilities, it is widely used in industrial automation, national defense resea...
I am currently working on a project that requires me to use STM32 to measure the frequency of a sensor. The sensor outputs a frequency signal, which is amplified and shaped to output a square wave. Th...
[align=left]Table of Contents[/align][align=left][url=Overview]Overview[/url][/align][align=left] [url=1. Overview of Achievement Goals:]1. Overview of Achievement Goals:[/url][/align][align=left][url...
Electric motors and internal combustion engines of the same power have similar torque levels. High power requires high torque, and torque determines a vehicle's acceleration speed, commonly known a...[Details]
On August 22, Lantu Motors officially launched its Lanhai Intelligent Hybrid technology via an online livestream. This intelligent hybrid technology, which integrates a full-range 800V high-voltage...[Details]
1. Fault phenomenon and cause analysis
1. During the operation of the equipment, the expansion sleeve is subjected to a large torque, and the mating surfaces of the shaft and the sleeve move...[Details]
A human-machine interface (HMI) refers to the platform used by people to operate a PLC. This platform provides an interface between programs and humans, serving as a medium for information transmis...[Details]
In the field of communications power supplies, AC/DC rectifier power supplies are called primary power supplies or basic power supplies, while DC/DC converters are called secondary power supplies. ...[Details]
There are many motors that can use thyristor speed control, and they can be used in almost all industries. Various types of motors, such as fans, pumps, AC motors, DC motors, torque motors, single-...[Details]
With the advancement of science and technology and the promotion of green, energy-saving, and circular development, the demand for precise control and accurate measurement is increasing. In the pow...[Details]
01. Introduction
As in-vehicle networks migrate from the CAN
bus
to
Ethernet
, traditional millisecond-level synchronization accuracy can no longer meet the requirements of mul...[Details]
According to Reuters, citing people familiar with the matter, British semiconductor design company Arm Holdings (NASDAQ:ARM) has hired Rami Sinno, head of Amazon's (NASDAQ:AMZN) artificial intellig...[Details]
Pure electric vehicles have experienced rapid growth in recent years, and many consumers now consider them as a top choice when purchasing a car. But do you know how to choose a satisfactory and sa...[Details]
The automotive transmission is the foundation of a vehicle's motion. The vehicle's drivetrain transfers engine power to the drive wheels, enabling the vehicle to move. The vehicle's drivetrain cons...[Details]
In industrial production, many different controllers are often used, such as those for pressure, flow, electrical parameters, temperature, and sound. However, due to the limitations of the on-site ...[Details]
As AI accelerates across industries, the demand for data center infrastructure is also growing rapidly.
Keysight Technologies recently announced the release of "Beyond the Bottleneck...[Details]
The solution uses AI to detect card-not-present fraud, a payment scam that causes significant losses to businesses.
Beijing, China, August 18, 2025 –
Telesign, a Proximus Global ...[Details]
How does air conditioning affect the range of pure electric vehicles? When I saw the question, my first thought was the impact on power consumption, similar to how air conditioning affects fuel con...[Details]